Open the battery compartment at the base of the device by pulling the cover using the recessed grip and 
remove the cover. Insert the four 1.5-volt batteries supplied (type AA, or similar) taking care to see that the 
batteries are positioned as designated on the left and right sides of the battery compartment. Then close 
the compartment, making sure that the plastic slides pass into their channels. Finally, press the cover closed 
until it clicks into place. Please make sure to read the point “Attention”!

Press the ON/OFF switch to start the Genius Air PLUS. The LED display illuminates, the device starts to run 
in factory preset mode “Low” and shows the current temperature. 
When switched on, the device automatically checks the condition of the batteries. If they need to be ex-
changed, the battery control lamp will glow (see “battery control display”). If the lamp does not glow, then 
the condition of the batteries is okay.
Press the ON/OFF switch again and the device switches off.

Monitoring the functions with the integrated LED display
The LED display illuminates blue for 5 seconds when any of the buttons are pressed.

Instructions for use

Status display

Mode setting

If the device is in a working phase, during which the negative ions for disinfection and air-freshening are 
distributed through the ventilation slots on the upper side of the device, the status display rotates as control 
in the LED display. 
The device switches into rest position between these working phases to conserve the batteries. The status 
display remains static.

In switched on condition, press the mode button to switch between two operating modes:

 

Mode ”Low“: After turning on, the device runs constantly for about 20 minutes. Then the device switches
into rest position for 40 minutes, and then follows an automatic phase of disinfection and air-freshening 
for 10 seconds every 60 minutes. 

 

Mode ”High“: After turning on, the device runs constantly for about 30 minutes. Then the device 
switches into rest position for 30 minutes, and then follows an automatic phase of disinfection and air-
freshening for 15 seconds every 60 minutes. 

In the remaining time the device switches into rest position, to conserve the batteries. 

Sketch 3:

Battery control display

Temperature display

Status display

Mode display

Selected temperature setting

3

Temperature monitoring

Battery control display

Light sensor

„Super-Fresh“

The ambient temperature in the refrigerator is automatically measured by the Genius Air PLUS and shown in 
the LED display. If the temperature falls below 0°C, then the minus-sign is automatically shown.
After putting the Genius Air PLUS into the fridge it can take several hours before the right temperature will 
be displayed. Please keep in mind that the lower areas of a refrigerator are colder that upper areas because 
warm air will rise up. When placed on the upper shelf of the refrigerator the temperatures in the lower 
shelves can be several degrees colder than shown on the LED display.
The factory setting for the temperature display is in degrees Celsius. Press the temperature select button) 
and the temperature display can be changed between either Celsius or Fahrenheit. The currently selected 
temperature units are shown in the display by „°C“ or „°F“.

If there are fully-charged batteries inside the device, then the battery control lamp cannot be seen. When 
the batteries in the device need to be exchanged, then a crossed-out battery symbol appears in the LED 
display, which blinks every 5 seconds. To change the batteries, proceed as described in step 1. Take care to 
see that the temperature of the housing corresponds to the room temperature (see “Caution“).
After exchanging the batteries the crossed-out battery symbol in the LED display disappears.

The Genius Air PLUS is equipped with a built-in light sensor. If the door of your refrigerator is open for more 
than 60 seconds, then the device will call your attention with a non-stop warning signal. This warning signal 
can be stopped by simply closing the refrigerator door. This way you never forget to close the refrigerator 
door – and it saves you energy. 
At the side of the base there is an alarm-slider, where the light sensor and thereby also the warning signal 
can be de-activated (push slider to “OFF“ position) and also re-activated (push slider to “ON“ position).

Press the “S/F“ button to start the “Super Fresh“ mode. This is especially wise when new food is deposited 
in the refrigerator, which may be contaminated with pollutants, bacteria or pesticides.
The Genius Air PLUS then begins with an additional neutralization sequence for a duration of 20 minutes. In 
addition to being shown in the LED-Display, the blue “Super Fresh“ LED control light blinks every 2 seconds.
Press the “S/F“ button again and the sequence is stopped. Press once more, and a new 20-minute neut-
ralization sequence starts.
After each additional neutralization sequence the Genius Air PLUS automatically switches back into rest 
position in the previously selected mode (”Low“ or ”High“).

In the base of the device there is a reset button. If for one reason or another, the device does not function 
correctly, then lightly press the reset button once with a small, thin, pointed object. The Genius Air PLUS will 
restart anew and function normally again.

Maintenance and cleaning

 

Only clean the unit with a moist cloth then dry thoroughly. 

 

Do not use scouring pads, rough cloths/sponges or caustic cleaning agents.