Genius Gate Systems DMG1 6/6 Setup Instructions Download Page 4

Gen

i

us Gate Systems Ltd

4 Wayside Green Woodcote Reading Berks RG8 0QJ

Mail@Genius-Systems.co.uk

Directors: D.M.Pearson. M.J.Thornton. J.A.Pearson

Registration No: 4557960 (England)

V.A.T.No: 815 9757 88

Page 4

Diagrams are attached for a 2 button system for two of the most common panels. Please contact us if

you have a different panel and we will advise on compatibility.

4. Test the system

Check all connections and once satisfied power up the DMG1and the Gate panel.

The Status indicator will start to flash quickly as the GSM unit tries to register with the network.

Once registration is complete the indicator will flash slowly.

NOTE the DMG will take approximately

60 seconds to complete its internal checks and read the data stored on the SIM before it will respond.

With a mobile phone (or landline) call the phone number issued with the SIM. The DMG will answer

the call after 3 or 4 rings and issue a simple Dit-Dit-Dit Dee sound to the caller. The call will hold for

about 30 seconds as the internal countdown timer runs out, during which time the caller can operate

the relays by pressing button1 on the phone for relay 1, button 2 for relay 2 and so on. Each button

press will reset the countdown time to 30 seconds run time. Successful relay operation results in a

Dit-Dit-Dit-Dee sound being issued. The sound for relay 2 however also indicates the status of the

relay. Being a Dit-Dit-Dit-Dee-Dee as the relay closes and a Dit-Dit-Dit-Doh-Doh as it opens.

Let the call drop once proper operation is established and initiate outbound calls by pressing the gate

buttons to call the target numbers loaded into the SIM earlier. Once again check for proper

operation. The Call forwarding will issue a beep when it activates and the current call will drop and

the alternate will set itself up. If there is no alternate the call forward trigger will reset to the first

number call when the trigger time is reached. It will not trigger a second time.

Version 3.2

October2008

Summary of Contents for DMG1 6/6

Page 1: ...ust be grounded and or connected to the Common line for all of the other equipment 4 A GSM Dual band Antenna with a Female FME connector This can either be directly connected to the flying antenna lead or via an extension lead and adaptors as needed The Antenna should have or be mounted on a metal base plate of at least 50mm x 50mm for best operation This may be part of the external cabinet Note W...

Page 2: ...combination as the DMG will not necessarily read them correctly If you need to re configure form one set to another you must power cycle the DMG to make sure it will read the new configuration 2 Load the SIM with the numbers in use Place the SIM card into any convenient Cellular phone and turn it on Set the memory in use to SIM only For Example in a Nokia Phone this is found under Names Settings M...

Page 3: ... will pick up at about 15 seconds in which case the call forward trigger will not act as the DMG cannot tell the difference between a person or a machine answering the call This means that some experimentation can be necessary Values less than 10 must be entered with a leading Zero e g 07 for 7 seconds Note If some buttons cannot have a second number then the DMG1 will redial the first number when...

Page 4: ...4 rings and issue a simple Dit Dit Dit Dee sound to the caller The call will hold for about 30 seconds as the internal countdown timer runs out during which time the caller can operate the relays by pressing button1 on the phone for relay 1 button 2 for relay 2 and so on Each button press will reset the countdown time to 30 seconds run time Successful relay operation results in a Dit Dit Dit Dee s...

Page 5: ...5 9757 88 Page 5 SPKR MIC 6 5 4 3 2 1 BUTTONS SPKR MIC 6 5 4 3 2 1 BUTTONS PSU 12 Vdc Videx 837M 1 2 S S1 P2 P1 C1 C Bn Wh Wh Bn Gn Wh Wh Gn Or Wh Wh Or Wh Bl Bl Wh CAT 5 Cable Bn Wh Wh Bn Gn Wh Wh Gn Or Wh Wh Or Wh Bl Bl Wh DMG1 6 6 Example connection diagram for a 2 button system Link Realy6 Relay 5 Relay4 Relay3 Relay2 Relay1 Realy6 Relay 5 Relay4 Relay3 Relay2 Relay1 To gate Control ...

Page 6: ...h Wh Gn Or Wh Wh Or Wh Bl Bl Wh DMG1 6 6 Example connection diagram for a 2 button system Link Realy6 Relay 5 Relay4 Relay3 Relay2 Relay1 To gate Control Call buttons SPKR MIC 6 5 4 3 2 1 BUTTONS SPKR MIC 6 5 4 3 2 1 BUTTONS PSU 12 Vdc COMELIT 1600 audio with 2 Button call 3 2 4 Bn Wh Wh Bn Gn Wh Wh Gn Or Wh Wh Or Wh Bl Bl Wh CAT 5 Cable Bn Wh Wh Bn Gn Wh Wh Gn Or Wh Wh Or Wh Bl Bl Wh DMG1 6 6 Exa...