background image

 

Model

 

SIE-L2 

Description 

Generator Interlock Kit for Siemens Left column Main 150-200 Amp 

Main Breaker

 

150 or 200 amp single handle Horizontal throw Right (on) Left (off)  

Generator Breaker

 

Top right side 2 positions 

 

 

   

WARNING 

Only qualified personnel should be working on the panel box 

An amateur should 

NEVER

 open the panel box 

Please follow all rules and regulations of the National Electric Code

 

 

Step 1:  Disassemble the interlock. Place the bottom plate (holes only) from edge of main breaker to bottom edge of generator breaker 

 

 

Step 2:  Turn off main breaker and remove panel cover.  

 

Step 3:  Drill holes as marked on panel cover with supplied 3/16 drill bit and remove all burs from drilling cover. 

 

Step 4:  Insert screws from rear of cover, install bottom plate, and install top plate (slotted) install retaining nuts, and thread lock. And 

Ensure proper movement. 

 

Step 5:  Install 2 pole Generator breaker on top right side and place Generator Warning Sticker on Generator breaker. 

 

Step 6:   Combine 2 zip ties and install zip tie under metal plate and around top of breaker as shown in picture below.  Pull on ends to 

make tight around breaker and trim ties as needed. Install warning label on zip ties next to breaker. 

 