Part No. 97550
Genie Superlift Advantage
3
Operator's Manual
Third Edition • Third Printing
SAFETY RULES
Electrocution Hazards
This machine is not
electrically insulated and
will not provide
protection from contact
with or proximity to
electrical current.
Keep away from the
machine if it contacts
energized power lines. Personnel must not touch or
operate the machine until power lines are shut off.
Maintain safe distances away from electrical power
lines and apparatus in accordance with applicable
governmental regulations and the following chart.
Allow for mast movement and electrical line sway
or sag, and be aware of strong or gusty winds.
Do not use the machine as a ground for welding.
Bodily Injury Hazard
Do not grasp the cable.
Do not place ladders or scaffolding against any part
of the machine.
Do not use the machine on a moving or mobile
surface or vehicle.
Do not exceed the rated load capacity. See Load
Capacity Charts section.
Avoid debris and uneven surfaces while rolling a
Genie Superlift with the legs folded up.
Do not replace machine parts critical to stability or
structure with items of different weight or
specification.
Do not use a straddle base or the flat forks on an
SLA-20 or an SLA-25.
Lifting Hazards
Use proper lifting techniques to load or tip the
machine.
Use proper lifting techniques when installing or
removing the load handling attachments.
Voltage
Minimum Safe
Approach Distance
Phase to Phase
Feet
Meters
0 to 300V
Avoid Contact
300V to 50KV
10
3.1
50KV to 200KV
15
4.6
200KV to 350KV
20
6.1
350KV to 500KV
25
7.6
500KV to 750KV
35
10.7
750KV to 1000KV
45
13.7