First Edition • Fifth Printing
Operator's Manual Supplement
Software Update
Part No. 1295772GT
4m Platform
13
Selecting the Platform Option.
The appropriate platform option must be
selected when installing or removing the
4m platform.
Tip-over hazard. Not selecting
the appropriate platform option
will result in death or serious
injury.
1
Press and hold buttons
2
and
3
. Pull out the
red Emergency Stop button to the on position.
2
You will be prompted for a password.
Enter
3 - 3 - 2 - 4
.
3
Press the
Settings
button to access the
settings menu.
Note: There will be a delay while the menu is
being loaded on the display screen.
4
Select
Options
. Press
OK
.
5
Select
Platform
. Press
OK
.
6
Select the appropriate platform. Press
OK
.
Standard
4m / 13 ft
7
Press
Escape
/
Escape
/
Escape
.
8
Push in the red Emergency Stop button to the
off position.
9
Perform a zero load platform calibration. Refer
to Repair Procedure,
How to Perform a Zero
Load Platform Calibration
in the Service and
Repair manual that is appropriate for your
machine.
10
Perform function test. Refer to the Operator's
Manual located on your machine.
Note: This step is only required if the machine
software has been updated.
11
Return the machine to service.