Part No. 72129
Genie Runabout
19
Operator's Manual
First Edition • Sixth Printing
Test Limited Drive Speed
40 Move the lift/drive select switch to the lift
position.
41 Press and hold the function enable switch.
Raise the platform approximately 2 feet /
60 cm from the ground.
42 Move the lift/drive selector switch to the drive
position.
43 Press and hold the function enable switch.
Slowly move the control handle to the full drive
position.
Result: The maximum achievable drive speed
with the platform raised should not exceed 0.7
feet / 20 cm per second.
If the drive speed with the platform raised exceeds
0.7 feet / 20 cm per second, immediately tag and
remove the machine from service.
FUNCTION TESTS
44 Press the drive speed switch or the drive speed
button until one of the drive speed indicator
lights turns off.
45 Press and hold the function enable switch.
Slowly move the control handle to the full drive
position.
Result: The maximum achievable drive speed
with the platform raised should be approximately
0.4 feet / 10 cm per second.
46 Press the drive speed switch or the drive speed
button again until two of the drive speed
indicator lights are off.
47 Press and hold the function enable switch.
Slowly move the control handle to the full drive
position.
Result: The maximum achievable drive speed
with the platform raised should be approximately
0.2 feet / 6 cm meters per second.