Genie INTELLIG 1000 3024 Operation And Maintenance Manual Download Page 13

©2010     The Genie Company 

12/2010

13

SECTIONAL DOOR

PORTE SECTIONELLE

PUERTA SECCIONAL

ONE PIECE DOOR

PORTE D’UNE PIÈCE

PUERTA DE UNA SOLA PIEZA

IF DOOR BE

COMES OB

STRUCTED

I

PULL DOW

N ON HAND

LE

LIFT SPRING

RESSORT DE LEVAGE

RESORTE DE ELEVACIÓN

*If required direct wiring of power supply to opener must be installed by a licensed electrician.  Power cord must reach 
grounded outlet without use of extension cord.

**Le câblage direct de l'alimentation d'énergie à l'ouvreur doit être installé s'il y a lieu par un électricien autorisé.  Le cordon de 
secteur doit atteindre la sortie au sol sans utilisation de corde de prolongation.

***Si es necesario, un electricista certificado debe instalar el cableado directo del suministro de energía al abre puertas.  El cable eléctrico 
debe llegar al enchufe con conexión a tierra sin utilizar un cable de extensión.

TYPICAL ONE PIECE DOOR INSTALLATION

    ...........  FOR HELP-1-800-35-GENIE OR WWW.GENIECOMPANY.COM

INSTALLATION TYPIQUE D’UNE PORTE DE GARAGE D’UNE PIÈCE 

 .............POUR OBTENIR DE L’AIDE-1-800-35-GENIE

INSTALACIÓN HABITUAL DE PUERTA DE UNA SOLA PIEZA

 ................................... PARA OBTENER AYUDA, LLAME AL 1-800-35-GENIE

FIG. 3-2  

WARNING

To reduce the risk of injury to persons or damage to property - 
Use this opener only with a one piece or sectional door.

AVERTISSEMENT

Pour diminuer le risque de blessures corporelles ou 
d’endommagement matériel - Utiliser cet l’ouvreur uniquement 
avec les portes à section.

ADVERTENCIA

Para reducir el riesgo de lesión a las personas o daños a la propiedad 
- utilice este abre puertas solamente con una puerta de una pieza o 
seccional.

SAFE-T-BEAM® SENSORS

PALPEURS de SAFE-T-BEAM® 

SENSORES SAFE-T-BEAM®

POWER CORD* TO 120V 
GROUNDED OUTLET

CÂBLE D’ALIMENTATION** 
À PRISE DE CONTACT DE 
120V À CONTACT DE MISE 
À LA TERRE 

CABLE DE ALIMENTACIÓN*** 
A UN TOMACORRIENTE DE 
120 V CONECTADO A TIERRA

HEADER BRACKET MOUNTING BOARD (not provided)

PLANCHE DE MONTAGE FACULTATIVE POUR SUPPORT 
D’EMBASE (non fourni)

TABLERO DE MONTAJE DE SOPORTE DEL UMBRAL 
(no se proporciona)

TYPICAL SUPPORT BRACKET (NOT PROVIDED) 

SUPPORT TYPIQUE (NON FOURNI)

ESCUADRA DE SOPORTE TÍPICA (NO SE INCLUYE)

Summary of Contents for INTELLIG 1000 3024

Page 1: ...WARNING To reduce the risk of injury to persons or damage to property Use this opener only with a one piece or sectional door SAVE THIS MANUAL FOR FUTURE REFERENCE INSTALLER LEAVE THIS MANUAL WITH HOM...

Page 2: ...ion which if NOT avoided will result in death or serious injury WARNING indicates a potentially hazardous situation which if NOT avoided could result in death or serious injury CAUTION indicates a pot...

Page 3: ...imits and force and program new remotes Automatic Lighting System Two bulb lighting system supplies up to 200 Watts of light for safer evening exits and entries Turns ON when door is activated and aut...

Page 4: ...learing Memory 15 IntelliCode Features 16 Previously Installed Openers 16 6 Maintenance Troubleshooting 17 26 Important Safety Instructions 17 Routine Monthly Maintenance 18 Door Balance SpringTension...

Page 5: ...assemblies and other hardware before installing the opener 3 Remove all ropes and remove or make inoperative all locks connected to the garage door before installing opener 4 Where possible install th...

Page 6: ...ns to open or close door A CLOSE DOOR TRAVEL LIMIT NOTE You can start and stop door movement using either buttons until door is in correct open or closed position Watch door move PROGRAMMING LIMITS FO...

Page 7: ...9 SET FORCE SET FORCE Force is set automatically with first full CLOSE OPEN door operation 7 8 9 10 Perform a successful CONTACT REVERSE TEST and then continue with remote programming NOTE To reset LI...

Page 8: ...6 7 and repeat steps 1 through 10 to correct down limit Stops after contacting the 2 x 4 board and does not reverse it may need an adjustment to the down limit Return to pages 6 7 and repeat steps 1 t...

Page 9: ...s preset for use with the IntelliCode 2 Access Security System Refer to page 16 for additional information on IntelliCode 1 and 2 remotes and how to switch from IntelliCode 2 to IntelliCode 1 See page...

Page 10: ...1 remote PRESS the same button and RELEASE SEE both LEDs on the powerhead come ON Blue The next press of the remote will operate door Test Repeat as necessary for any other IntelliCode 1 remotes Geni...

Page 11: ...rieur du rail Cadena o correa ubicada dentro del riel Carriage Slide located inside rail Coulisse du chariot situ l int rieur du rail Deslizamiento del carro ubicado dentro del riel o carril Bullet B...

Page 12: ...ring of power supply to opener must be installed by a licensed electrician Power cord must reach grounded outlet without use of extension cord Le c blage direct de l alimentation d nergie l ouvreur do...

Page 13: ...COM INSTALLATION TYPIQUE D UNE PORTE DE GARAGE D UNE PI CE POUR OBTENIR DE L AIDE 1 800 35 GENIE INSTALACI N HABITUAL DE PUERTA DE UNA SOLA PIEZA PARA OBTENER AYUDA LLAME AL 1 800 35 GENIE FIG 3 2 WAR...

Page 14: ...und Red and Long Red Round Purple and Long Purple Round Blue and Long Blue Programming Overview There are four Powerhead program menus Remote Program Default menu Limits Program Speed Program Force Pr...

Page 15: ...death 1 Keep people clear of opening while door is moving 2 Do NOT allow children to play with opener including wall console remote or wireless keypad 3 During programming the door opener could begin...

Page 16: ...um of 3 different openers can be programmed to a 3 button remote Programming remote to previously installed IntelliCode 1 Genie garage door openers Remotes provided with this unit can operate other In...

Page 17: ...nt toute utilisation desdits metteurs Sendeger te entsprechen allen gesetzlichen Bestimmungen in den USA und Kanada zum Zeitpunkt der Herstellung Wir bernehmen keine Gew hrleistung f r die Einhaltung...

Page 18: ...available Unapproved or incompatible wall consoles can cause the opener to operate unexpectedly Safe T Beam STB SYSTEM CHECK STB Red and Green LEDs ON steady system OK STB Red LED flashes Check for o...

Page 19: ...ner Open powerhead light cover Remove light bulb s Replace with maximum 100 Watt light bulb s Do NOT use light bulbs with greater than 100 Watt rating Close powerhead light cover 2 Reconnect power to...

Page 20: ...e Lock Press and release to turn Sure Lock OFF OPTIONAL DUAL WALL CONSOLE INSTALLATION Use only a Series III wall console when adding a second wall console The optional second Genie Series III wall co...

Page 21: ...ail rest on rail Do NOT overtighten Is there rust on chain or frayed edges on belt Contact a trained door system technician for chain belt replacement Are there kinks or twists in the chain or belt Co...

Page 22: ...Press PROGRAM SET on the powerhead and hold until both lights turn steady ON Release button Lights go out and Round BLUE light comes ON 2 Press two times and the Round BLUE and Long BLUE lights come O...

Page 23: ...quires no adjustment for normal operation Never increase the door closing force to compensate for a damaged door or a binding door track Never adjust force to compensate for a broken door spring Perfo...

Page 24: ...ly set See pages 6 7 Check if Safe T Beam Red LED is flashing See page 18 Check Safe T Beam system for beam obstruction or misalignment of lenses See page 18 Check garage door for binding If an operat...

Page 25: ...r system technician ON RED STEADY ON RED STEADY Limits NOT set properly Reprogram Limits see pages 6 7 ON RED FLASHING ON RED FLASHING Program error Unplug unit wait 5 seconds plug in Component failur...

Page 26: ...CONECTADOR WHITE BLANC BLANCO BLACK NOIR NEGRO GREEN VERT VERDE WHITE BLANC BLANCO WHITE BLANC BLANCO BLACK NOIR NEGRO RED ROUGE ROJO BLACK NOIR NEGRO STRIPED WHITE BLANC RAY BLANCO RAYADO WALL CONSOL...

Page 27: ...sales or repairs or maintenance to door components ALL EXPRESS AND IMPLIED WARRANTIES FOR THE PRODUCT INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULA...

Reviews: