background image

www.GenieCompany.com/commercial

   |   

800.843.4084

 ©2012 The Genie Company

  |  

GCL-Tss

GCL-T  

|

  

STANDARD-DUTY TROLLEY OPERATOR

MAX DOOR SIZE (SQ*FT) - SECTIONAL

Door Series

Commercial Steel Insulated & Non-Insulated

Thermospan

®

ThermoMark

Aluminum

216

216 

Ins.

220

220 Ins.

2415

2415 

Ins.

2411

2411 

Ins.

125

150

200

200-20

5150

5200

451

452

Flush

Ribbed

Insulated

Insulated

Model

Max 

Door Wt. 

(lbs)

16GA.

16GA. 

Ins.

20GA. 

Steel

20GA. 

Ins.

24GA.

24GA. 

Ins.

Nominal 

24GA.

Nominal 

24GA. 

Ins.

PU-FIP

PU-FIP 

1.38”

PU-FIP 

2”

PU-FIP 

2”  

20GA. 

Ext.

PU-FIP 

Raised 

Panel 

1.38”

PU-FIP 

Raised 

Panel 

2”

1/8” 

Glass 

1.38”

1/4” or 

1/2” 

Glass 

1.38”

1/2 HP

1120

256

220

370

256

440

340

320

320

256

360

400

300

400

380

360

240

3/4 HP

1370

330

256

440

310

530

400

320

320

256

450

450

370

460

440

400

330

1 HP

1620

380

280

500

370

570

410

320

320

256

480

480

420

500

480

400

400

1. Max Door Weight and not the square footage, is the critical factor in selecting the proper operator.
2. Max Door Height 24’
3. For “Commercial Steel Insulated” category, various “backer” options are available. The chart above is based in all cases on the thickest backer available.
4. “PU-FIP” stands for “polyurethane, foamed-in-place.” If no notation is present, insulation is “polystyrene laid-in-place.”

Notes: 

Accessories and Options

•  Timer to Close Module

 

Timed close set via the LCD display from 2 seconds up to 5 minutes. 
Includes pre-close warning contacts, timer hold input, auxiliary open input, 
normally closed safety input, and monitored edge input.

•  Auxiliary Output Module

 

Provides relay contacts at the open, close, and mid-stop limits. Contacts 
for 5-minute lamp, and “ADA” contacts set via LCD display to warn during 
opening, closing or both.

•  Intellicode

®

 I Transmitters

 

Available in single up to four button, or open/close/stop models.

•  Environmental Modifications

 

Totally enclosed non-ventilated, or fan-cooled motors available - Must be 
ordered from the factory. Nema 4 or Nema 4X environmental modifications 
- Must be ordered from the factory.

•  UL325-2010 Approved Reversing Devices  

The installation of a monitored external entrapment device is required for 
momentary contact close operation on all commercial door operators. Only 
the following devices, when purchased through Genie, are UL-Approved 
for use to meet this requirement: 

•  Safe-T-Beam

®

 Photoeye Kit with adjustable bracket P/N 38176R.S 

1

•  Impact-protected Commercial Photoeye Kit P/N OPAKPE.S 
•  MillerEdge ME/MT/CPT (DC or T3) 2-wire edge sensor. Must be used 

with TCM (OPABTCGX.S) or Interface Module (OPAKMEIGX.S).

•  Nema 4 Photoeyes P/N OPAKPEN4GX.S

1

— Default device when operator is ordered.

Construction

•  Motor

 

AC continuous-duty motor. Motor replaceable without 
changing limits. Thermally protected.

•  Drive

  

Primary — TensiBelt

 auto tensioning poly-V J belt.  

Secondary — chain and sprocket reduction.

•  Brake 

24VDC disc brake standard on 3/4 and 1 HP models; option 
on ½ HP models.

•  Friction Clutch

 

Adjustable clutch to help protect against door and operator 
damage.

•  Precision Radial Ball Bearings 

Included in critical areas throughout the powertrain.

•  Rail Assembly

 

2” heavy-gauge roll formed angle with nylon chain guides.

•  Emergency Disconnect

 

Drawbar disconnect via pull cord for manual operation of 
door.

•  Pre-wired to accept: 

 

- Monitored entrapment device such as photo eyes.  
- Single or 3-button control stations.  
- External interlock switches.

Dealer Imprint Area

AMPERAGE RATING - 60Hz

Hp

115V 1Ø 208V 1Ø 230V 1Ø 208V 3Ø 230V 3Ø 460V 3Ø 575V 3Ø

1/2

10

5

5

3

3

3

2

3/4

11

6

6

3

4

3

2

1

14

7

7

4

4

3

2

Reviews: