Maintenance

Refer maintenance to qualified technicians. Please disconnect power 
and signal wire before maintaining fixtures.

In order to preserve OBY-5 in good condition, keep the routine 
maintenance by following date.

The Steps are as follows:

Take the filter out (See Figure.) and clean it every two weeks.

The dichroic colour-filters, the metal gobo-wheel, the internal lenses 
and cooling fans should be cleaned with soft brush monthly.

The interior of the fixture should be cleaned at least half-yearly using 
a vacuum-cleaner or an air-jet.

Caution:

 Be careful not to damage the interior mechanical structures 

or circuits when using the air-jet.

To ensure a proper function and smooth rotation of the gobo-wheel, 
we recommend lubrication in six-month intervals.

Caution:

 Avoid the damage of interior structures when fixtures 

rotated, do not use excess lubrication.

Due to emit fog frequently, the optical lens and gobos would be oily; 
thus luminosity would be weak. We recommend using moist cloth or a 
trace of detergents to wipe them every two weeks. (Prohibit using the 
detergents consisted of alcohol and solvents.)

Filter

15

Summary of Contents for MOVING HEAD OBY-5

Page 1: ...TM MOVING HEAD OBY 5 User manual CAUTION...

Page 2: ...nimating stages If any question or suggestion you have please offer the precious recommendation for improving our products and designs better and create perspective and expectancy about future lightin...

Page 3: ...zed which allows version update or customization more convenient Sophisticated optical system makes light output more bright and sharp Simple and easy operation Standard USITT DMX512 protocol 16 or 14...

Page 4: ...Description of the appearance Filter 2...

Page 5: ...amage or loss caused by transportation Contact your Geni dealer to assure your right by telephone or facsimile immediately if damage has occurred or if something is missing Packing List A OBY 5 Moving...

Page 6: ...o qualified technicians only Lamp and components become hot during operation Allow time to cool before handling Keep flammable material at least one meter away from unit Do not operate in wet conditio...

Page 7: ...cover and put it aside Loosen and grab the screws on the shutter cover with appropriate tool Wear the gloves and extract the lamp from the package loosen the screws on both sides of the lamp then sli...

Page 8: ...arious venues Mount two attached brackets a on the bottom See Figure and collocate the appropriate clamps b to rig with trusses Must use the safety ropes that can hold the ten times as heavy as the fi...

Page 9: ...he DIP SWITCH 3 of last fixture to ON position for terminal confirmation 1 2 3 1 2 3 1 Ground 2 Signal 3 Signal 1 Ground 2 Signal 3 Signal DMX output XLR mounting socket DMX input XLR mounting plug Co...

Page 10: ...top cover Refer to the steps of lamp installation and loosen the screws with appropriate tools then extract A See the figures below 4 Insert the new GOBO and the spring ring Press the spring ring tigh...

Page 11: ...st max 7 flashes second Channel 2 Shutter Strobe Open white Steel Blue Orange Green Blue Bright Blue Bright Pink Red Deep Blue Yellow Dark Pink Moss Green Light Blue Color wheel rotation slow to fast...

Page 12: ...13 27 41 55 69 83 97 111 125 139 153 167 255 0 14 28 42 56 70 84 98 112 126 140 154 168 Yellow Yellow Steel Blue Green Channel 4 Color wheel 2 Channel 5 ixed gobo wheel Channel 6 Rotating gobo wheel...

Page 13: ...m static 1 7 132 253 255 0 2 8 133 254 Channel 9 Iris Closed Min Diameter to max diameter Iris in from slow to fast Iris out from fast to slow Open 159 207 253 255 0 1 160 133 254 Iris in Iris out Cha...

Page 14: ...r Standby 47 95 159 207 255 0 48 96 160 208 Channel 12 Tilt reguration The head of the unit is allowed to turn vertically from zero to 270 degrees Channel 13 Pan fine tune While rotating horizontally...

Page 15: ...ontrol channels 8 bit protocol DMX Channel Function 1 DIMMER 2 SHUT 3 COLOR 1 4 COLOR 2 5 GOBO 1 6 GOBO 2 7 GOBO 2 ROTATE 8 PRISM AND ROTATE 9 IRIS 10 FOCUS 11 PAN COARSE 12 TILT COARSE 13 AUTO RESET...

Page 16: ...Control Board 14...

Page 17: ...re should be cleaned at least half yearly using a vacuum cleaner or an air jet Caution Be careful not to damage the interior mechanical structures or circuits when using the air jet To ensure a proper...

Page 18: ...on before replacing the fuse Replace the fuse as follows Step 1 Unscrew the screw of the fuse holder on the housing counterclockwise with appropriate tools Step 2 Remove the broken fuse and then repla...

Page 19: ...Product Specifications Dimensions 400x380x540mm LxWxH Weight 26 kg Voltage 230V 50 60Hz Fuse 10A 250V Signal USITT DMX512 Lamp MSI 575 2 17...