GENI mojo scan I MJC-1XA User Manual Download Page 5

Getting Ready

All Geni products are thoroughly tested at the factory and shipped in perfect 
condition. If damage has occurred during shipping or if components are 
missing, please contact your Geni dealer immediately.

Your package should include:

TM 

(1) One Mojo Scan I scanner lighting   with bracket.
(2) One IEC electric mains power cord with plug.
(3) One product user manual.

The lamp may or may not be included, depending on your Geni dealer. In most 
cases, the lamp is not included.

Install the Lamp (

MJC-1XA)

MJC-1XA   use either the GX5.3 24V/250W lamp by Osram or the ELC lamp of 
identical specifications by Philips. Use only the appropriate lamp for your unit. 
Note that product versions that use other lamps may be offered in the future. 
Check your product specification label for information.

Lamp Installation (

MJC-1XA)

(1) Loosen the two screws on the top of the lamp cover. Open the case. 
(2) Read lamp instructions. Do not touch the lamp bulb glass. (See Figure 1.) 

Oil on hands shortens the lamp life. (If you touch the bulb glass, wipe off 
the glass with a clean, lint-free towel and rubbing alcohol.)

(3) Hold the lamp socket with one hand. Insert the lamp pins into the holes in 

the lamp socket. 

(4) Make sure that the lever is up. Slide the lamp into the lamp base. 
(5) Put on the lamp cover and fasten the screws snugly.

A

B

C

D

E

Lamp Items

A - Lever
B - "ELC" Lamp
C - Lamp Base
D - Lamp Socket
E - Lamp Pins
                

Figure 1

DMX Set Up

Unit 4

Unit 3

Unit 2

Unit 1

Mojo

Mojo

Mojo

Mojo

DMX OUT

DMX Controller

DMX IN       DMX OUT

DMX IN            DMX OUT

DMX IN            DMX OUT

DMX IN            DMX OUT

Note: Link all DMX cables and
set dip switches before con-
n e c t i n g   e l e c t r i c   p o w e r .

Figure 4

3. Set DMX dip switches as follows:
MJC-IXA,IYA       Dip ON        
Unit 1                       #1                          
Unit 2                       #3                       
Unit 3                       #1#2#3                
Unit 4                       #2#4               
For more units, continue to use standard DMX dip switch settings. See
Appendix 1 for details.
4. On the last in a series of units, flip "on" the Terminate dip switch (Term.   

dip switch). This keeps the signal clear. Make sure other function dip

     switches are "off".
5. Supply electric power: Plug electric mains power cords into each unit's 

IEC  socket 

, then plug the other end of the mains power 

cord into proper electric power supply sockets. Do so for all units and the 
controller. 

(see figure 5)

Do not supply power before the whole system is set up and 

connected properly.

6. Design your show according to your DMX controller functions. Do 

not supply power before the whole system is set up and connected 
properly.DMX channel functions are shown on pages 6.

Product Operation Overview

In audio mode (func. dip switch "on"), choose various shows by flipping regular dip 
switches on the first unit. For example, for a slow, four-unit audio show, flip "on" func. 
dip switch   on the first unit to activate audio mode, then flip regular dip switches #2 and 
#6 "on" to activate a slow-paced, four-unit audio show. (See the following Function 
Channel Chart.) 
Do not activate audio dip switches on following units, but set their DMX channels 
according to regular DMX procedures. (See Appendix 1 for an introduction to DMX dip 
switch settings.)
One final note: Terminate all systems by flipping "on" the (Term.) Dip switch on the last 
unit. This preserves clear signal transmission in both audio and DMX modes.