UPHO

ULTIMATE HOMOGENIZER

USER MANUAL

Summary of Contents for UPHO

Page 1: ...UPHO ULTIMATE HOMOGENIZER USER MANUAL...

Page 2: ...s Unpacking and Packing List Removal of the Transport Security System Sample Adapter Installation 6 Operating Procedures Automatic Program User defined Program 7 Cleaning User Maintenance 8 Troublesho...

Page 3: ...etween 10 C to 40 C transported and stored in temperatures between 0 C to 50 C with relative humidity less than 70 Do not disassemble modify or remodel the unit or accessories This device should be ke...

Page 4: ...PHO should only be operated by suitably qualified and trained personnel in accordance with Good Laboratory Practice Do not make any modifications of the instrument Disassembly will void the warranty U...

Page 5: ...r replace any internal parts of your UPHO if there is a fault please call for professional service When UPHO is not in use switch it off at the power switch on the back panel of the unit please see pi...

Page 6: ...ety shoes Operators must not operate the equipment if feeling unwell 3 Introduction The traditional sample grinding with a Pestle Mortar is a very slow method that can only process one single sample a...

Page 7: ...enomic DNA The ergonomic design of the instrument ensures an easy loading of the disposable centrifuge sample tubes that remain securely sealed during the grinding process effectively avoiding sample...

Page 8: ...onds to reach maximum speed Power rating 195 W Power requirement 220 V 240 V 50 Hz 2 5 A 375 W UPHO dimensions 460 460 530 mm length width height Weight 35 kg Operating temperature 10 C 40 C relative...

Page 9: ...Structure Overview Front Protective cover Security screw Adaptor retainer Display screen Operation panel Cover latch Structure Overview Back ON OFF button Power supply plug Foam 7...

Page 10: ...he quantities on the list below If anything is missing please contact your supplier You will also find detailed information on the contents of the package on the packing list in the shipping crate UPH...

Page 11: ...ransport Security System A transport security system is located on the underside of UPHO comprised of 4 bolts circled on picture below THIS SYSTEM MUST BE REMOVED BEFORE OPERATING THE UPHO Remove the...

Page 12: ...on the sample adaptor Open the protective cover on the sample compartment cover by releasing the cover latch remove the security screw if present and slide the sample adapter and cover on to the adapt...

Page 13: ...ogram The program will not start if the protective cover is open or the cover latch is not secured For hard samples you can use the following adaptors and cans 6 Operating Procedures Suggestions and r...

Page 14: ...ill appear in the screen together with a green light By touching the screen you can execute several operations Decelerate button to decrease grinding speed Accelerate button to increase grinding speed...

Page 15: ...ain program defined by the user When the user touches a box it will turn yellow 3 After that please touch the Modify button at the bottom of the screen The Modify button will turn yellow as well after...

Page 16: ...name touch the box on the Group column in the same line as the yellow Choose box 6 After that a pop window will appear as follows 7 Write the name of the program by touching the different keys Click o...

Page 17: ...button to start the grinding process 11 The user can always modify later its own programs by choosing a certain program on the Group column 12 After a long period of time non use time the main menu w...

Page 18: ...econds Turn the UPHO back on Check main voltage Check that the voltage of the unit matches that being delivered by the main power supply Make sure the unit is plugged in properly Check and replace fus...

Page 19: ...ight to change alter modify or improve any of its instruments without any obligation whatever and to make corresponding changes to any instrument previously sold or shipped 10 Disposal End of Life Dis...

Page 20: ...stic environment this product may cause radio interference in which case the user may be required to take adequate me asures Signed Date January 15th 2018 Mr B Coissac Title ManagingDirector For and o...

Page 21: ...International Standards particularly The Waste Electrical and Electronic Equipment WEEE Directive and the Reduction of Hazardous Substances RoHS Directive EN 61010 1 Safety requirements for electrical...

Page 22: ...12 UPHO Accessories 20...

Page 23: ...s at info geneye com Because of technological developments related to the products systems and or services described herein the data and procedures are subject to change without notice Please consult...