PRE-OPERATION CHECK

 

 
Fuel Recommendation 
1. Check the fuel level gauge. 
2. Refill the tank if the fuel level  is low. Do not fill above the shoulder of the fuel 
strainer. 
 

 

 

Gasoline  is  extremely  flammable  and  is  explosive  under  certain 
conditions. 

 

Refuel in a well-ventilated area with the engine stopped. Do not smoke 
or  allow  flames  or  sparks  in  the  area  where  the  engine  is  refueled  or 
where gasoline is stored. 

 

Do not overfill the fuel tank (there should be no fuel in the filler neck). 
After refueling, make sure the tank cap is closed properly and securely. 
Be careful not to spill fuel when refueling. Spilled fuel or fuel vapor may 
ignite. If any fuel is spilled, make sure the area is dry before starting the 
engine. 
Avoid repeated or prolonged contact with skin or breathing of vapor. 

 

KEEP OUT OF REACH OF CHILDREN. 

 
Fuel tank capacity: 25.0

 

 (SG5300,  SG6500, S G7600)

 

                     

   

 

                     11.0 

 (SG3200) 

 

        

      

 
Use gasoline with a pump octane rating of 86 or higher 
We recommend  unleaded  gasoline  because  it  produces  fewer  engine  and  spark 
plug deposits and extends exhaust system life. 
Never  use  stale  or  contaminated  gasoline  or  oil/gasoline  mixture.  Avoid  getting 
dirt or water in the fuel tank. 

 

17 

FUEL LEVEL GUAGE 

FUEL STRAINER 

FUEL TANK CAP 

Summary of Contents for SG3200DX

Page 1: ...Owner s Manual SG series DX EX Dream Power Products Co Ltd 2015...

Page 2: ...wner s manual describes the operation and maintenance of the GENEX generator All information in this publication is based on the Dream Power Products reserves the right to make changes at any time wit...

Page 3: ...USLY HURT if you don t follow instructions You CAN be KILLED or SERIOUSLY HURT if you don t follow instructions You CAN be HURT if you don t follow instructions Each message tells you what the hazard...

Page 4: ...round Terminal 9 Oil Alert System 9 Pilot Lamp 10 DC Terminals 10 DC Circuit Protector 10 GENERATOR USE 11 Connections to a building s Electrical System 11 Generator Ground Circuit 11 AC Applications...

Page 5: ...TENTS MAINTENEACE 21 Maintenance Schedule 21 Engine Oil Change 22 Air Cleaner Service 23 Fuel Sediment Cup Cleaning 24 Spark Plug Service 25 TRANSPORTING STORAGE 27 TROUBLESHOOTING 29 SPECIFICATONS 31...

Page 6: ...ause loss of consciousness and may lead to death If you run the generator in an area that is confined or even partially enclosed the air you breathe could contain a dangerous amount of exhaust gas To...

Page 7: ...for a while after stopping the engine Be careful not to touch the muffler while it is hot Let the engine cool before storing the generator indoors Gasoline is extremely flammable and is explosive und...

Page 8: ...uel valve Air cleaner Recoil starter grip Engine switch Engine serial number Oil drain bolt Oil filer cap AC receptacle AC circuit breaker DC circuit breaker DC terminal Fuel tank cap Fuel meter Spark...

Page 9: ...ON position once the engine has started Do not use the starter for more than 5 seconds at a time If the engine fails to start release the switch and wait 10 seconds before operating the starter again...

Page 10: ...ank to the carburetor Be sure to return the lever to OFF after stopping the engine Choke Rod The choke is used to provide an enriched fuel mixture when starting a cold It can be opened and closed by o...

Page 11: ...t breaker ON again Ground Terminal The generator ground terminal is connected to the frame of the generator the metal non current carrying parts of the generator and the ground terminals of each recep...

Page 12: ...connected to the generator DC terminals with the proper polarity battery positive to generator red terminal and battery negative to the generator black terminal DC Circuit Protector The DC circuit pr...

Page 13: ...by law to be registered with local utility companies Check local regulations for proper registration and use procedures Generator Ground Circuits GENEX portable generators have a system ground that co...

Page 14: ...ubstantial overloading will open the circuit breaker Exceeding the time limit for maximum power operation or slightly overloading the generator may not switch the circuit breaker OFF but will shorten...

Page 15: ...orized appliances require more than their wattage for startup Do not exceed the current limit specified for any one receptacle If an overloaded circuit causes the AC circuit breaker to switch OFF redu...

Page 16: ...nerator positive terminal 4 Connect the negative battery cable to the negative terminal 5 Connect the other end of the negative battery cable to the generator negative terminal 6 Start the generator D...

Page 17: ...other end of the negative battery cable from the battery negative terminal 4 Disconnect the positive battery cable from the generator positive terminal 5 Disconnect the other end of the positive batte...

Page 18: ...irements for Service Classification SG SF CC CD Motor oils classified SG SF CC CD will show this designation on the container 1 SG SF CC CD SINGLE VISCOSITY 2 SG SF CC CD MULTI VISCOSITY SAE 10W 30 is...

Page 19: ...sure the tank cap is closed properly and securely Be careful not to spill fuel when refueling Spilled fuel or fuel vapor may ignite If any fuel is spilled make sure the area is dry before starting th...

Page 20: ...grain alcohol Gasoline containing more that 10 ethanol by volume may cause starting and or performance problems Gasoline containing ethanol may be marketed under the name Gasohol Methanol methyl or w...

Page 21: ...ou want to operate the choke manually move the choke rod out to the CLOSED position 4 Start the engine with recoil starter Turn the engine switch to the ON position Pull the start grip lightly until r...

Page 22: ...engine switch to the OFF position In normal use 1 Turn the AC circuit breaker to the OFF position 2 Disconnect all electrical loads from panel receptacles Disconnect DC battery charging cables 3 Turn...

Page 23: ...GULAR SERVICE PERIOD Perform at every indicated month or operating hour interval whichever comes first Each use First month or 20 hrs Every 3 months or 50 hrs Every 6 months or 100 hrs Every year or 3...

Page 24: ...d motor oil may cause skin cancer if repeatedly left in contact with the skin for prolonged periods Although this is unlikely unless you handle used oil on a daily basis it is still advisable to thoro...

Page 25: ...nerator without the air cleaner Rapid engine war will result 1 Unsnap the air cleaner cover clips remove the air cleaner cover and remove the element 2 Wash the element in a solution of household dete...

Page 26: ...r a long time the sediment cup should be cleaned 1 Turn the fuel valve to the OFF position Remove the sediment cup O ring and filter 2 Clean the sediment cup O ring and filter in nonflammable or high...

Page 27: ...muffler 1 Remove the spark plug cap 2 Clean any dirt from around the spark plug base 3 Use the wrench supplied in the tool kit to remove the spark plug 4 Visually inspect the spark plug Discard it if...

Page 28: ...lling a new spark plug tighten 1 2 turn after the spark plug seats to compress the washer If reinstalling a used spark plug tighten 1 8 1 4 turn after the spark plug seats to compress the washer The s...

Page 29: ...than 1 month No preparation required 1 to 2 months Fill with fresh gasoline and add gasoline conditioner 2 months to 1 year Fill with fresh gasoline and add gasoline conditioner Drain the carburetor...

Page 30: ...he engine oil 3 Remove the spark plug and pour about a tablespoon of clean engine oil into the cylinder Crank the engines several revolutions to distribute the oil then reinstall the spark plug 4 Slow...

Page 31: ...ck 1 Remove the spark plug cap and clean any dirt from around the spark plug 2 Remove the spark plug and install the spark plug in the plug cap 3 Set the plug side electrode on the cylinder head 4 Cra...

Page 32: ...he AC circuit breaker ON Check the electrical appliance or equipment for any defects Take the generator to an authorized GENEX generator dealer Replace the electrical appliance or equipment Take the e...

Page 33: ...Oil alert system YES YES YES YES Starting system Recoil Recoil GENERATOR Frequency Hz 50 60 50 60 Type 4 stroke overhead valve single cylinder Voltage regulation system AVR Phase Single AC output KVA...

Page 34: ...em Transistor Oil alert system YES YES YES YES Starting system Recoil Recoil GENERATOR Frequency Hz 50 60 50 60 Type 4 stroke overhead valve single cylinder Voltage regulation system AVR Phase Single...

Page 35: ...stor Oil alert system YES YES YES YES Starting system Recoil Electric Recoil Electric GENERATOR Frequency Hz 50 60 50 60 Type 4 stroke overhead valve single cylinder Voltage regulation system AVR Phas...

Page 36: ...ansistor Oil alert system YES YES YES YES Starting system Recoil Electric GENERATOR Frequency Hz 50 60 Type 4 stroke overhead valve single cylinder Voltage regulation system AVR Phase Single AC output...

Page 37: ...Dream Power Products Co Ltd...

Reviews: