DIN Rail 12V 4A Intelligent Power Supply

SY-SIX-PSU-DIN-4A

Installation Manual

Document last updated June 04, 2019

Summary of Contents for Synergis IX SY-SIX-PSU-DIN-4A

Page 1: ...DIN Rail 12V 4A Intelligent Power Supply SY SIX PSU DIN 4A Installation Manual Document last updated June 04 2019...

Page 2: ...not reflect the product at all times in the future In no event shall Genetec be liable to any person or entity with respect to any loss or damage that is incidental to or consequential upon the instru...

Page 3: ...Output Current Influence on Output Load Operation 16 Core Temperature on Output Load Operation 16 Inputs Zones 17 Trouble Inputs 17 Outputs 18 Online Mode 18 PGM Outputs 18 Offline Mode 18 AC Fail St...

Page 4: ...rror Code Display 24 Mechanical Diagram 25 Mechanical Layout 26 Technical Specifications 27 New Zealand and Australia 28 European Standards 29 FCC Compliance Statements 31 Industry Canada Statement 32...

Page 5: ...rk architecture allows large numbers of modules to be connected to the RS 485 module network Up to 250 modules can be connected to the Genetec Synergis IX system in any combination to the network over...

Page 6: ...installed in accordance with The product installation instructions The National Electrical Code ANSI NFPA 70 The Canadian Electrical Code Part I CSA C22 1 The Local Authority Having Jurisdiction AHJ I...

Page 7: ...other factors The integrity of all ground connections should be checked periodically General safety dictates that all metal parts are connected to earth with separate copper wire or wires of the appro...

Page 8: ...ote that the DIN Rail enclosure earth terminal is connected to the power supply V terminal There must be only one single earth grounding point per system Grounding Requirements Last updated June 2019...

Page 9: ...accessible area of the ceiling 1 Hook the upper tabs over the top edge of the DIN Rail 2 Push the Power Supply against the DIN Rail mount until the lower tab clips under the lower rail Removal The Pow...

Page 10: ...Wiring Diagram Mounting Last updated June 2019 10...

Page 11: ...is installation should be made by qualified service personnel and should conform to all local codes Termination of wiring to the Power Supply while power is applied or the battery is connected may cau...

Page 12: ...re uses a special algorithm to prevent deep discharge and increase battery endurance A dynamic battery test is performed every ten minutes when mains power is present and a battery condition alarm wil...

Page 13: ...o the NA and NB terminals of the communication network Network Power Supplied by Network Module The diagram above shows a power connection taken from the auxiliary power outputs on the Power Supply s...

Page 14: ...round in the same cable to a maximum length 100m 328ft Warning Unused wires in the cable must not be used to carry power to other devices End of Line EOL Resistors The 330 Ohm EOL End of Line resistor...

Page 15: ...e current output of 4 0 Amps is required then both outputs need to be connected together in parallel When any inductive load including electric locking devices is powered directly or indirectly by the...

Page 16: ...utput Over Current Failure Trouble Input Activated Over Current Output Shutdown Activated Core Temperature on Output Load Operation The table below helps illustrate how the core temperature of the pow...

Page 17: ...ble type and group that they activate Input Number Description Type Group AExxx 01 Module Tamper System Tamper System AExxx 02 Mains Failure Power Fault General AExxx 03 Low Battery Battery Failure Po...

Page 18: ...w shows the control of an external LED indicator Note Switching inductive loads that can produce high back EMF voltages or large voltage induced spikes can cause the Power Supply to behave unexpectedl...

Page 19: ...put relay contacts disconnect Normally Open when either the backup battery has been disconnected or when the Power Supply is running on backup battery power without AC power and the backup battery vol...

Page 20: ...nterface Monitoring Setup The Power Supply will register with the Genetec Synergis IX Controller as an Analog Expander module AExxx The channels for each Power Supply will monitor Channel 1 Voltage at...

Page 21: ...ng and will require entry of the module serial number The serial number can be found on the identification sticker on the product Refer to the Genetec Synergis IX System Controller installation manual...

Page 22: ...ill return to normal operation Fault Indicator The fault indicator is lit any time the module is operating in non standard mode If the fault indicator is flashing the module requires a firmware update...

Page 23: ...temperature exceeded Over Temp Shutdown Activated Flashing red Core temperature within 10 C of Over Temp Shutdown On green Core temperature OK Output Current Indicator The Output Current indicator sho...

Page 24: ...dule using the module update application 3 Address Too High The module address is above the maximum number available on the system controller To clear this error change the address to one within the r...

Page 25: ...Mechanical Diagram The mechanical diagram shown below outlines the essential details needed to help ensure the correct installation of the Power Supply Mechanical Diagram Last updated June 2019 25...

Page 26: ...Mechanical Layout The mechanical layout shown below outlines the essential details needed to help ensure the correct installation of the Power Supply Mechanical Layout Last updated June 2019 26...

Page 27: ...VDC Communication RS 485 Isolated Module Network Outputs PGM Outputs 2 Solid State Relay Outputs 50mA 12V Max each Inputs Tamper Dedicated Hardware Tamper Input Trouble Inputs 8 internal Dimensions Di...

Page 28: ...nd Australia General Product Statement The RCM compliance label indicates that the supplier of the device asserts that it complies with all applicable standards New Zealand and Australia Last updated...

Page 29: ...e environment which could otherwise arise from inappropriate waste handling Please contact your local authority for further details of your nearest designated collection point Penalties may be applica...

Page 30: ...lied by the capacitive clamp injection method disturbance signal voltage level 1 kV for both polarity for 1 minute Slow high energy voltage surge EN 50130 4 ed 2 EN 61000 4 5 ed 2 Tests EMC operationa...

Page 31: ...uraged to try to correct the interference by one or more of the following measures Re orient the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into...

Page 32: ...ement This class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme la norme NMB 003 du Canada CAN ICES 3 A NMB 3 A Industry Canada Statement Last u...

Page 33: ...the Genetec Logo are trademarks of Genetec Inc and may be registered or pending registration in several jurisdictions Other trademarks used in this document may be trademarks of the manufacturers or...