Sanyo
genetec.com | Omnicast Video Unit Configuration Guide 4.8 SR3
78
EN.100.007-V4.8.C3.(1)
Sanyo
This section describes the additional configuration steps required for some Sanyo, and Sanyo
ONVIF compliant units to work in Omnicast.
This section includes the following topics:
•
•
Configure VCC-HD5X00 units
Your unit must have two video streams that are configured before adding the unit to the
Archiver.
1
Open the unit’s Web page.
2
Click on
VIDEO/AUDIO
.
3
Under
STREAM
, set
STREAM 1
to
H.264,
and
STREAM 2
to
JPEG
.
Add Sanyo ONVIF units
For Sanyo ONVIF compliant units to work in Omnicast, specific Manufacturer and HTTP port
settings are required when the units are added in the Config Tool.
1
In the
Physical view
of the Config Tool, click
Create
(
).
2
Click
Video Unit
to open the
Add a unit
dialog box.
3
Select the desired Archiver.
4
In the
Manufacturer
field, select
Sanyo
.
5
In the Unit Type field, select
ONVIF
.
6
Enter the appropriate IP address.
7
In the
HTTP port
field, enter
8080
.
8
Enter the appropriate username and password, and click
Add
.