Product Operation and Specifications
Important Information
If this or any other system is installed in a metal (conductive) plumbing system, i.e. copper or
galvanized metal, the plastic components of the system will interrupt the continuity of the
plumbing system. As a result any errant electricity from improperly grounded appliances
downstream or potential galvanic activity in the plumbing system can no longer ground
through contiguous metal plumbing. Some homes may have been built in accordance with
building codes, which actually encouraged the grounding of electrical appliances through the
plumbing system. Consequently, the installation of a bypass consisting of the same material
as the existing plumbing, or a grounded "jumper wire" bridging the equipment and re-
establishing the contiguous conductive nature of the plumbing system must be installed prior
to your systems use.
Specification Description
GO600
GO1000
Rated Service
Flow Rate
8
GPM
1
6
GPM
Peak Flow Rate
12
GPM
Minimum Working Pressure
25
PSI
Maximum Working Pressure
80 PSI
Operating Temperatures
36°F – 120°F
Read these instructions carefully and determine the location of all system components before
beginning installation.
Check all applicable plumbing, building, and electrical codes for installation compliance.
Install the system on the main water supply.
The use of Teflon Tape and/or Pipe Thread Seal Paste will be needed on all threaded connections.
Only for use on municipally supplied water.
WARNING:
pH Range
6 – 11
1