8.  TECHNICAL SPECIFICATIONS

 cations

Power supply

24 Vac +10 to -15%, 50/60Hz, 1 VA
22 to 35 Vdc, 0.5W
Class 2 safety power supply
Min. cable cross-section 0.5 mm

2

.

Power supply compatible with compactSteam (G – G0)

Operating temperature

0 to 60°C,  32 to 140°F, 10 to 90% rH not-condensing

Storage temperature

-20 to 70°C, -4 to 140°F, 10 to 90% rH not-condensing

Precision of inside temperature measurement

±1°C from 0 to 60 °C,    ±2°F from 32 to 140 °F

Precision of outside temperature measurement

± 1.5°C from 0 to 40°C  ± 2.0°C  from -40 to 0 and 40 to 80 °C
± 3°F from 32 to 104°F  ± 4°F  from -40 to 32and 104 to 176 °F

 

0 to 10 V analogue output, not isolated, for proportional control

precision ±5%
max load 5 kΩ, max current 2 mA

Relay approval

EN60730-1: NO 1(1)A 250 Vac cos = 0.4, 100,000 cycles
UL-873: NO 1A resistive 24 Vac, 30  Vdc, 100,000 cycles
PILOT DUTY: 24 Vac, peak 15 A, continuous 1 A, 30,000 cycles

Precision of humidity measurement (in models where featured) 

range 10 to 90%%

± 3% rH at 25°C , 77 °F
± 5% rH 0 to 60°C, 32 to 140°F

Dimensions (mm):

135x86x36mm

Tab. 5.a

8.2 Wiring

:

n

o

i

s

r

e

v

 

d

e

t

a

l

o

s

i-

n

o

N

t

u

p

n

l

a

ti

g

i

D

direct connection of the voltage-free contact; contact closing current: 3 to 5 mA

.

Isolated version:

with external power supply to 24 Vac contact: class 2 safety external power supply separate from the 24 
Vac power supply to the instrument

Outside temperature sensor connection 

with standard sensor (10 K 25 °C B=3435):

Maximum length: 30 m, min. cable cross-section 0.5 mm

2

.

Digital input connection

Maximum length 10 m, min. cable cross-section 0.5 mm

2

.

Analogue output connection

Maximum length 10 m, min. cable cross-section 0.5 mm

2

.

Relay output connections:

Maximum length 30 m, cable cross-section from 1.5 to 2.5 mm

2

, class 2 reinforced insulation from the 

instrument.
Basic insulation between the relays.

 cations for connections:

Use copper wires approved for a temperature of 75 C.

To tighten the terminals, apply a torque of 7 Lb/In for the black terminals (SAURO)
To use the instrument in compliance with UL-873, a load with a maximum voltage 24 Vac, class 2, can be 
connected to the relay output.

Tab. 5.b

Warning:

  All  the  connections,  except  for  the  relays,  must  be 

connected to very low voltage circuits with reinforced insulation.

10

Summary of Contents for GFX50

Page 1: ...GFX50 Residential Humidistat User manual Revision 1 1...

Page 2: ...vironments that comply with the temperature and humidity limits do not install the device in particularly hot environments Too high temperatures may reduce the life of electronic devices damage them a...

Page 3: ...buttons 6 3 2 Description of the buttons 6 4 CONFIGURATIONS 7 4 1 Setting the Dip Switches 7 4 2 Setting Parameters 7 4 3 Auto Humidity Control 7 4 4 Sensor Calibration 8 4 3 Additional Functions 8 5...

Page 4: ...nections are complete before Note For the purposes of electrical safety EN60730 1 once the controller has been installed replace the plastic locking tab in the humidistat base Accessories and dipswitc...

Page 5: ...connectioins See Fig 2 b Note the factory See Elite Steam Manual GFX50 ON D P 1 2 3 4 DIPSWITCHSETTNGS ON OFF OFF ON Fig 2 c GFX50 terminal 1 and 2 See Fig 3 x 2 3 4 Placement of Remote Outdoor Tempe...

Page 6: ...ttons to increase or decrease the time Press a second time to exit and return to the main menu If sleep mode is already active pressing the button shows the time remaining on the timer E g if in Night...

Page 7: ...When the time bands are set the CLOCK symbol is shown on the display PARAMETERS check set the other parameters dIF dS1 based on the mode used Note Note If AUTO humidity mode is enabled the humidity s...

Page 8: ...mer This value can be changed at any time To exit the menu press the NIGHT button again 5 FUNCTIONS 5 1 H humidity control This type of control is used to send a start signal to a humidifier or dehumi...

Page 9: ...re OFF 1H to 7H OFF 7 ALARMS AND SIGNALS Note three dashes are displayed 7 1 Table of alarms code on display ect EE system memory error manual stops all outputs Eth temperature humidity sensor fault a...

Page 10: ...86x36mm Tab 5 a 8 2 Wiring n o i s r e v d e t a l o s i n o N t u p n i l a t i g i D direct connection of the voltage free contact contact closing current 3 to 5 mA Isolated version with external po...

Page 11: ...Note...

Page 12: ...NERAL FILTERS INC 43800 GRAND RIVER AVE NOVI MICHIGAN 43875 1115 WWW GENERALAIRE COM CANADIAN GENERAL FILTERS LTD 400 MIDWEST POAD TORONTO ONTARIO M1P3A9 WWW CGFPRODUCTS COM Agency Form GFX50 05 Rev 1...

Reviews: