5
6
7
8
Manufacturer
Title
: ISIPARK İÇ DIŞ TİC. A.Ş.
Address
: Fatih Mah. 1188 Sk. No:13/A Sarnıç
Gaziemir İzmir-TURKEY
Tel: +90 (232) 457 99 50
Fax: +90 (232) 457 91 22
E-Mail: [email protected]
Authorized Signatory:
Company Stamp:
Product
Type: Digital Room Thermostat
Brand: GENERAL Life
Model: SOLARA
330S RF
Guarantee Period: 5 Years
Max. Time to Repair: 20 Days
Banderole and Serial Number:
WARRANTY CERTIFICATE
V-01.2022
Vendor
Title:
Address:
Tel:
Fax:
E-Mail:
Invoice Date and Number:
Delivery Time and Place:
Authorised Signatory:
Company Stamp:
Product
Type: Digital Room Thermostat
Brand: GENERAL Life
Model: SOLARA 330S RF
STAMP
Isıpark reserves the rights of changing product specifications and user manuals.
*For all changes,you may visit generallife.com.tr
WEEKLY PROGRAM
You may set the operating schedule of your Room Thermostat with weekly program
mode. 7 different temperature values can be set for each day in weekly
programming. These values can be set in temperature adjustment screens '' P0-P6''.
In order to set the weekly schedule, press and hold the “Weekly Program“ button
for 3 seconds while your Room Thermostat is on.
The
“Hour, Minute and Day”
setting will appear. Press
the
“Heating & Cooling Option” button until
the
“Weekly
Program” menu (P0) appears.
Days of the week will be blinking on the screen. You can initiate the weekly
program setting if you wish to set the same schedule for every day of the week.
Press the “Up“ button once if you wish to set the same schedule for the weekdays.
First five days of week will be blinking on the screen.
Press the “Up“ button once more if you wish to set the same schedule only for the
weekend. Last two days of the week will be blinking on the screen.
Press the “Up“ button one more time if you wish to set the same schedule for
every day of the week. 1st day of the week will be blinking on the screen. You can
switch between the days by pressing the “Up“ button. Press the “Down“ button in
order to switch to the previous day.
Press the “Weekly Program“ button once to set a schedule.
“P0” will be blinking on the screen. Set the temperature value of “P0” by pressing
the “Weekly Program“ button once more. The hour setting of “P0” cannot be
changed since it's factory setting.
Press the “Weekly Program” button again. Day indicator will be blinking. If you will
not change the day, press the “Weekly Program” button again and switch to the
“P1” setting by pressing the “Up” button.
First, hour setting will appear on the screen. Once you complete the hour setting,
adjust the minute setting by pressing the “Weekly Program” button. After the
minute setting, press
the
“Weekly Program” button to set the temperature value.
Follow the same steps for other schedule settings.
Once all changes made, press and hold the “Weekly Program” button for 3
seconds to save.
Note
:
In order to check the weekly schedule which has been set without making any
changes, press the “Weekly Program” button once while your Room Thermostat is
on. Press the “Up” and “Down” buttons to see the days, press the “Mode” button to
see the settings between “P0-P6”.
TPI ROOM THERMOSTAT WORKING LOGIC
Y
our Room Thermostat works with the TPI algorithm. Room Thermostats using TPI
technology predict when the temperature of your home will rise above or below the
set temperature and turn the heating
/ cooling
unit on and off accordingly. This
ensures that your home stays at the temperature you set without maximum
deviations up and down.
W
hat is TPI?
T
PI technology is designed to ensure that you get the best possible energy
efficiency from your heating
/ cooling
system. It measures and applies the best
possible timings to deliver and maintain your home at the set temperature level.
H
ow does TPI work?
T
hanks to the advanced artificial intelligence technology found in the software, it
adapts to the temperature change of the environment in which it is located. By
creating a general temperature map of your home, it learns how long it takes to
reach the desired room temperature and how to maintain this temperature. In this
way, it provides minimum energy consumption by calculating how long your
heating
/ cooling
unit should work for.
W
hat is the difference?
I
n non-TPI room thermostats, the heating
/ cooling
unit works and stops
continuously until it exceeds the set temperature value. If the set temperature
drops below a certain amount, the heating
/ cooling
unit will work again. This
creates greater temperature fluctuations and less energy control. TPI Room
Thermostats, on the other hand, provide higher savings and comfort compared to
On/Off room thermostats with the advantages it has.
Heating Mode
Your room thermostat takes the average room temperature of last 40 seconds as
basis.
With the TPI algorithm in the product by creating a general temperature map
of your home, it learns how long it takes to reach the desired room temperature and
how this temperature is maintained.
Thus, it ensures that the room temperature
remains within a certain range.
TPI ROOM THERMOSTAT HEATING MODE WORKING GRAPHIC
Cooling Mode
Your room thermostat takes the average room temperature of last 40 seconds as
basis.
With the TPI algorithm in the product by creating a general temperature map
of your home, it learns how long it takes to reach the desired room temperature and
how this temperature is maintained.
Thus, it ensures that the room temperature
remains within a certain range.
TPI ROOM THERMOSTAT COOLING MODE WORKING GRAPHIC
Your Room Thermostat sends the last status signal to the Receiver every 10
minutes. Thus, your Room Thermostat and Receiver work synchronously. If the
signal cannot reach to the Receiver from the Room Thermostat for 22 minutes, it
perceives that the connection is broken and stops the heating/cooling operation for
safety reasons. Likewise, in cases where the electricity comes back after a power
failure, the Receiver does not operate the heating/cooling unit until 'operate' signal
reaches from the Room Thermostat. However, in this case, if the Room Thermostat
continues to operate normally, it will continue to work properly without any need for
intervention since it sends a status signal to the Receiver every 10 minutes.
WHAT TO KNOW ABOUT TPI ROOM THERMOSTAT
If the placement of the TPI Room Thermostats is changed, the learning process
will restart. The learning process should be considered as 7 days.
If the TPI Room Thermostats are de-energized (battery replacement), the learning
process will restart. The learning process should be considered as 7 days.
FREQUENTLY ASKED QUESTIONS
Is my Room Thermostat compatible with my heating/cooling unit?
If your heating/cooling unit has On-Off connections, your Room Thermostat is
compatible. You can find information about your heating/cooling unit from your
heating/cooling unit operating manual or from your heating/cooling unit service.
How will I connect my heating/cooling unit with my Receiver?
We recommend that the connection between the Receiver and heating/cooling unit
should be made by professionally qualified persons.
2x0.75 mm cable is sufficient for the Receiver – heating/cooling unit connection.
Connect one end of the cable pair to the room thermostat connection terminals
stated in the user manual of your heating/cooling unit.
Connect the other end of the cable pair to COM and NO inputs of the terminal inside
the Receiver as shown in the "RECEIVER WIRING DIAGRAM" section.
The direction of the cable ends does not matter.
DECLARATION OF CONFORMITY
ISIPARK İÇ VE DIŞ TİC. İNŞ. ISITMA SİSTEMLERİ OTO. SAN.A.Ş. which Head Office
and production site is located on Fatih Mah. 1188 Sk.No:13/A Sarnıç - Gaziemir -
İZMİR – TÜRKİYE confirms and declares that the product marked with CE and its
specifications below is covered by the provisions of the mentioned directive.
Brand
Product Name
Product Type
Compatible Directives
:
Radio and Telecommunications Terminal Equipment Regulation
2014/53/EU
(R&TTE/RED EN 301 489-1 V2.1.1:2017,
EN 300 220-1 V3.1.1:2017, EN 301 489-3 V2.1.1:2017,
EN 300 220-2 V3.1.1:2017, EN 62479: 2010)
Electromagnetic Compatibility Regulation
2014/30/EU
(EMC EN 61000-6-3: 2007 + A1: 2011, EN 61000-6-1: 2007)
Low Voltage Directive
2014/35/EU
(LVD EN 60730-2-9:2010, EN 60730-1:2011)
Additional Information: The mentioned product can be used with heating/cooling
units with On-Off output and compliance with the directives only covers the
product. ISIPARK is not responsible for the entire system's compliance with the
directives. This statement is not valid if changes are made to the product without
our approval.
: GENERAL Life
: SOLARA 330S RF
: Digital Room Thermostat
23
30
5
TEMPERATURE
(ºC)
Desired Temperature
TPI Room Thermostat
Time
23
30
5
TEMPERATURE
(ºC)
Desired Temperature
TPI Room Thermostat
Time
WARRANTY CONDITIONS
1- The warranty period starts from the invoice date and warranted against
manufacturing defects for
5
years.
2- Devices and apparatus are delivered to the customer in working condition in our
company. On-site commissioning is subject to a service fee.
3- The repair of the devices and apparatus covered by the warranty is carried out in
our company factory and should send by contracted transportation company. In on-
site services, the transportation and accommodation expenses of the service
personnel belong to the customer. The shift fee during transportation is added to
the service fee and collected in advance.
4- The maintenance of devices and apparatus is done in our company. For the
maintenance of the devices and apparatus, the round travel fares belong to the
customer.
5- In case of malfunctioning of the devices and apparatus whose warranty period
continues, it is tested in our company whether the malfunction is caused by a
customer or manufacturer fault, and it is reported with a report issued by our
company.
6- In case of detection of manufacturer-induced errors of devices and apparatus
whose warranty period continues, the customer can request a replacement or
repair of the devices and apparatus at full expense by the manufacturer, unless it's
higher than the product's price.
7- In the event that the faults of the devices and apparatus whose warranty period
continues are determined as caused by the customer, all expenses would belong to
the customer.
8- Customers should be aware of damages (if there is any) of product and warn
manufacturer since the day warranty duration starts. If customer do not warn
manufacturer with knowledge of damage, customer lose the rights of article 6.
9- Malfunctions resulting from the use of devices and apparatus contrary to the
matters stated in the User Manual are not covered by the warranty.
10- Devices and their apparatus are out of warranty if they are beaten, broken or
scratched by the customer.
11- Damages resulting from the use of devices and apparatus belonging to other
brands and models without the approval of the manufacturer are not covered by the
warranty.
12- Battery leakage and errors due to rust, oxidation and liquid contact by working in
acidic / humid environments are not covered by the warranty.
13- When the product is not used for a long period (more than 15 days), remove the
batteries. Otherwise, malfunctions that will occur are out of warranty.
14- Damages that may occur during the transportation of devices and apparatus are
not covered by the warranty. Customers can take transportation insurance.
15- Damages caused by mains voltage / faulty electrical installation are not covered
by the warranty.
16- Devices and apparatuses are out of warranty for malfunctions caused by force
majeure such as fire, flood, and earthquake etc.
17- All of the devices and apparatuses, including all their parts, are under the
warranty of our company.
18- In case of malfunction of the devices and apparatuses within the warranty
period, the time spent during repair period is added to the warranty period. The
repair period of the product cannot exceed 20 working days. This period starts from
the date of notification to the service station of the malfunction related to the
product or, in the absence of a service station, to the seller, dealer, agency,
representative, importer or manufacturer of the product. Consumer can report the
problem by; phone, fax, e-mail, registered and reply paid letter or a similar way.
However, in case of a conflict, responsibility of prove is belong to the customer. If
the malfunction of the product is not repaired within 20 working days, the
manufacturer-producer or importer; has to allocate another product with similar
features to the use of the consumer until the repair of the product is completed,
19- Although the consumer uses his/her repair rights, -If the product breaks down
for 4 times in a year or 6 times in warranty duration and these problems effects main
purpose of the product. (Starting from delivery time during warranty.) -Exceeding
the maximum time required for repair, -In the event that the service station is not
available, if it is determined that the repair of the defect is not possible with the
report prepared (in order) by one of the seller, dealer, agency, representative,
importer or manufacturer, a refund or a price discount at the rate of defect can be
requested.
20- The customer can make complaints and appeals to consumer courts or
consumer arbitration committees.
21-
The warranty document must be kept by the customer during the warranty
period. If the document is lost, a second document will not be issued. In case of
loss, repair and replacement of devices and apparatus will be made for a fee.