Before cleaning the P16PIP, disconnect the H16 (DCS1600) console from the
probe, remove the console from the mounting bracket and cover the probe
connector with the red protective cap, as shown above.

All parts of the probe and reel can be hosed down or cleaned with a cloth and
water or a mild solvent. After cleaning, allow fluid to drain from the unit for at
least five minutes. Then dry the unit carefully with a second cloth before
returning it and any accessories to the plastic case.

Note:

All compatible consoles and probe controllers are NOT waterproof. 

Be sure to disconnect your borescope and move it out of the way before
washing the P16PIP.

12

Summary of Contents for P16PIP

Page 1: ...PIPE DUCT INSPECTION PROBE REEL SET USER S MANUAL P16PIP 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com ...

Page 2: ...ctions 4 What s in the Case 4 Product Overview 5 6 Setup Instructions 6 7 Attach Borescope 6 7 Operating Instructions 8 10 Attaching an Accessory 8 10 Operating Maintenance Tips 11 12 Specifications 13 Warranty Information 14 General s Return for Repair Policy 15 2 ...

Page 3: ...S1600 DCS1600ART and DCS1800 Recording Video Borescope Inspection Systems H16 Handheld Recording Console the DCS1600 System without a probe DCS1800 TR Transmitting Probe Handle Controller which enables video and images captured by the P16PIP probe to be viewed on the console of a DCS1800ART system KEY FEATURES Ideal for examining the interior of water pipes sewer pipes and HVAC ducts Especially ta...

Page 4: ... inspect ducts known or suspected to contain live electric wiring WHAT S IN THE CASE The P16PIP Pipe Duct Inspection Probe Reel Set comes in a hard plastic protective case along with this user s manual and the following accessories One spherical metal ring for centering the probe in 2 in I D pipes One brush set for centering the probe in 4 in I D pipes One brush set for centering the probe in 6 in...

Page 5: ...iarize yourself with the names and positions of these components before moving on to the Setup and Operating Instructions Fig 1 The key components of the P16PIP 5 Camera head Borescope console holder Probe guide camera head stopper Handle Reel frame Coiled probe Reel stopper Probe connector to borescope console or handle controller ...

Page 6: ...patible with the following systems and components from General The DCS1600 DCS1600ART and DCS1800 Recording Video Borescope Inspection Systems The H16 Handheld Recording Console the DCS1600 System without a probe 6 Camera head Rubber probe cover Joint ball Probe Accessory mounting ring Metal coil spring sleeve ...

Page 7: ...lign this dot with the red dot on the connector of your borescope console or handle controller and push the two connectors together To secure the connection release the collar and turn it clockwise until tight The following figure shows the final attachment step for an H16 DCS1600 Console At the top of the P16PIP is a metal bracket designed to securely hold the H16 DCS1600 console If you are using...

Page 8: ...o keep the camera head from getting hung up on the pipe s sidewalls as you push the probe forward That is more likely if you use the probe to inspect large pipes or rectangular ducts In such situations friction will often cause the camera head to tuck under the probe as you push it forward producing a rear facing dynamic view of the pipe s interior When you begin to reel in the probe however the m...

Page 9: ...he Probe guide camera head stopper see Fig 1 Then if this is the first use of the P16PIP or its first use in months pull and push the end of the probe back and forth a few times see figure at right to reduce any friction binding the reel s stationary and moving parts Once you have played out a few feet of probe lock the reel by fastening the Velcro closure around the reel frame as shown below 9 ...

Page 10: ... the camera head see Fig 2 Secure the ring to the head by using the included Allen wrench to tighten the screw as shown at right To attach either probe centering brush set identify the end with three set screws Passing the camera head through the other end first slide the probe through the brush set until the camera head protrudes 1 8 in past the end with the set screws see figures below In this p...

Page 11: ... an angle greater than 90 see figures at right below Before attempting to wind the probe back onto the reel remember to unlock the reel by undoing the Reel stopper see Fig 1 The most effective way to rewind the probe is to push it onto the reel through the bars of the Probe guide see Fig 1 horizontally from a distance of about 12 inches Continue pushing until the Joint ball has passed through the ...

Page 12: ... reel can be hosed down or cleaned with a cloth and water or a mild solvent After cleaning allow fluid to drain from the unit for at least five minutes Then dry the unit carefully with a second cloth before returning it and any accessories to the plastic case Note All compatible consoles and probe controllers are NOT waterproof Be sure to disconnect your borescope and move it out of the way before...

Page 13: ...ight Source 8 white LEDs Camera Depth of Field 0 4 in 10mm to infinity Camera Field of View 150 8 diagonal Waterproof Depth IP68 50 ft 10m Operating Temperature 14 to 158 F 10 to 70 C Weight 4 9 lb 2 2kg REEL Frame Diameter 11 8 in 300mm Dust and Water Resistance To IP65 standard Operating Temperature 14 to 158 F 10 to 70 C Weight 6 6 lb 3kg 13 ...

Page 14: ...empted repair by non authorized personnel or misuse alterations normal wear and tear or accidental damage The defective unit must be returned to General Tools Instruments or to a General authorized service center freight prepaid and insured Acceptance of the exclusive repair and replacement remedies described herein is a condition of the contract for purchase of this product In no event shall Gene...

Page 15: ...r instrument requires repair please contact our Customer Service to obtain an RGA Return Goods Authorization number before forwarding the unit via prepaid freight to the attention of our Service Center at this address Remember to include a copy of your proof of purchase your return address and your phone number and or e mail address 15 ...

Page 16: ...hout notice 2012 GENERAL TOOLS INSTRUMENTS NOTICE WE ARE NOT RESPONSIBLE FOR TYPOGRAPHICAL ERRORS MAN P16PIP 3 27 12 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com ...

Reviews: