background image

IRT670

USER’S MANUAL

High Performance 30:1, Wide-range
Infrared Thermometer with Memory

INTRODUCTION:

Thank you for purchasing this Infrared Thermometer. This is a non-contact infrared temperature measuring instrument. To
measure a temperature, point the unit at the desired object, pull the measuring trigger and hold. Make sure the target area is
larger than the unit’s spot size. For larger target objects, you must be within the target distance.

IRT670 Manual-FINAL3-050608:Layout 1  5/6/08  9:40 AM  Page 1

Summary of Contents for IRT670

Page 1: ...r This is a non contact infrared temperature measuring instrument To measure a temperature point the unit at the desired object pull the measuring trigger and hold Make sure the target area is larger...

Page 2: ...product is not designed for use in medical evaluations The product can only be used to measure body temperature for reference It is meant for industrial and scientific purposes SAFETY SYMBOLS Dangero...

Page 3: ...y Adjustable 0 1 1 0 F C Switchable YES Backlight YES Laser Sight Switchable YES Audible alarm YES Max Min Avg T YES Auto Measuring YES 10 Point Memory YES Dual Display YES Tripod Mount YES Dimensions...

Page 4: ...e temperature within one shot measuring The highest and lowest temperature difference within one shot measuring Recall the stored data by using or button Emissivity for more accuracy on different mate...

Page 5: ...S OF INFRARED THERMOMETER FIELD OF VIEW FOV RATIO DISTANCE TO DIAMETER DS RATIO The field of view is the angle of vision at which the instrument operates and it is determined by the optics of the unit...

Page 6: ...9 95 unoxidized 127 260 0 06 Copper 199 390 0 18 599 1110 0 19 Steel 199 390 0 52 599 1110 0 57 Zinc galvanized sheet iron bright 28 82 0 23 Brass highly polished 247 476 0 03 Brass hard rolled polish...

Page 7: ...e temp rature Alarmes sonores APPLICATIONS Proc d s de fabrication de technologie de semi conducteurs R paration et entretien des automobiles S curit et traitement de l alimentation Audits nerg tiques...

Page 8: ...its Disposez donc de ce produit de mani re appropri e et conform ment la r glementation applicable SP CIFICATIONS Ratio distance point de mesurage 30 1 Gamme de temp rature 25 6 1400 F 32 760 C Pr cis...

Page 9: ...ne 12 Valeur de r glage d enregistrement 13 Touche de verrouillage 14 Touche de mode 15 Bouton de mont e Mode de r glage des param tres Lecture et affichage de la temp rature durant le mesurage La tem...

Page 10: ...ES DE THERMOM TRE INFRAROUGE RATIO DU CHAMP DE VISUALISATION FOV RATIO DE DISTANCE AU DIAM TRE DU POINT DE MESURAGE Le champ de visualisation est l angle de vision sous lequel l instrument fonctionne...

Page 11: ...99 95 pur non oxyd 127 260 0 06 Cuivre 199 390 0 18 599 1110 0 19 Acier 199 390 0 52 599 1110 0 57 Fer en feuille recouvert 28 82 0 23 de zinc galvanis brillant Laiton hautement poli 247 476 0 03 Lai...

Page 12: ...guro electr nico en el gatillo Memoria para dato de temperatura Alarmas sonoras APLICACIONES Procesos de fabricaci n con de tecnolog a de semiconductores Reparaciones y mantenimiento de autom viles Se...

Page 13: ...bricantes gremios y plantas de tratamiento involucrados en el ciclo de vida de los productos Deseche este instrumento apropiadamente de acuerdo a los reglamentos correspondientes ESPECIFICACIONES Rela...

Page 14: ...datos 4 T Emisividad 5 Alarma Temp Alta Baja 6 Tecla de memoria 7 Bot n para disminuir 8 SCAN HOLD AUTO MEDIR AUTO 9 Opci n F C 10 Pantalla principal de temperatura 11 M x M n Prom 12 Configurar Regi...

Page 15: ...que o el objetivo m s cerca debe usted estar de ste Cuando el di metro del objetivo es peque o es importante acercarle el term metro para asegurarse de medir s lo su temperatura y no la de sus alreded...

Page 16: ...70 0 94 Hierro fundido derretido 1299 1399 3270 2550 0 29 Cobre pulido 21 117 70 242 0 02 Cobre brillante rascado no al espejo 22 72 0 07 Cobre placa fuertemente oxidada 25 77 0 78 Esmalte blanco fund...

Reviews: