General IRT659K User Manual Download Page 13

13

WARRANTY INFORMATION

General Tools & Instruments’ (General’s) IRT659K 12:1 Infrared Thermometer
with “K” Type Thermocouple & Adjustable Emissivity is warranted to the original
purchaser to be free from defects in material and workmanship for a period of
one year. Subject to certain restrictions, General will repair or replace this
instrument if, after examination, the company determines it to be defective in
material or workmanship. The warranty period begins on the date of purchase.
You are encouraged to register your product online. General will extend your
warranty an additional 60 days if you register at
www.generaltools.com/Product Registry.

This warranty does not apply to damages that General determines to be from
an attempted repair by non-authorized personnel or misuse, alterations, normal
wear and tear, or accidental damage. The defective unit must be returned to
General Tools & Instruments or to a General-authorized service center, freight
prepaid and insured.

Acceptance of the exclusive repair and replacement remedies described herein
is a condition of the contract for purchase of this product. In no event shall
General be liable for any incidental, special, consequential or punitive damages,
or for any cost, attorneys’ fees, expenses, or losses alleged to be a
consequence of damage due to failure of, or defect in any product including,
but not limited to, any claims for loss of profits.

Register now at www.generaltools.com/ProductRegistry to receive a 60-day
extension to your warranty.

RETURN FOR REPAIR POLICY

Every effort has been made to provide you with a reliable product of superior
quality. However, in the event your instrument requires repair, please contact
our Customer Service to obtain an RGA (Return Goods Authorization) number
before forwarding the unit via prepaid freight to the attention of our Service
Center at this address:

General Tools & Instruments
80 White Street    New York, NY 10013
212-431-6100

Remember to include a copy of your proof of purchase, your return address,
and your phone number and/or e-mail address.

Summary of Contents for IRT659K

Page 1: ...12 1 INFRARED THERMOMETER with K TYPE THERMOCOUPLE ADJUSTABLE EMISSIVITY USER S MANUAL IRT659K Please read this manual carefully and thoroughly before using this product...

Page 2: ...issivity and Setting Temperature Alarms 8 10 Recalling Logged Measurements 10 Using the K Type Probe to Measure Temperature 10 11 Full Specifications 11 12 Operating Maintenance Tips 12 Warranty Infor...

Page 3: ...rmocouple a 9V battery and this user s manual are sold together with a nylon pouch in a blister pack KEY FEATURES SPECIFICATIONS 12 1 distance to spot D S ratio 58 to 1202 F 50 to 650 C IRT measuremen...

Page 4: ...u from looking at the beam long enough to cause harm As a precaution keep the IRT659K out of the hands of children especially if you have pets Never stare at the laser beam through binoculars or a mag...

Page 5: ...ttery compartment E LCD F MODE SET button G LOG button H F C button I IR K TC button J button K K type thermocouple probe shown inserted in socket L Laser Identification Certification Warning Safety L...

Page 6: ...he yellow measurement trigger Fig 1 Callout C while pointing the unit anywhere The LCD s blue backlight will illuminate and the unit will chirp If neither happens the battery is dead and must be repla...

Page 7: ...f the IRT659K is available in scanning mode In scanning mode you typically squeeze and hold the trigger while aiming the gun at many different surfaces in an environment The IRT659K automatically reme...

Page 8: ...f an object to reflect or absorb IR radiation energy can be assigned any value between 0 10 and 1 00 in steps of 0 01 The default factory setting of is 0 95 Because the IRT659K measures the amount of...

Page 9: ...E SET button with the instrument powered on and operating in any mode Whatever the operating mode pressing and holding the MODE SET button will cause the emissivity icon to begin flashing You can now...

Page 10: ...o oldest 1 Power on the unit by squeezing the measurement trigger 2 Release the trigger to exit scan mode 3 Press the LOG button once The value of the most recent measurement will appear in the smalle...

Page 11: ...ent Accuracy 3 F 2 C or 2 of reading whichever is greater above 32 F 0 C 4 F 3 C or 3 of reading whichever is greater below 32 F K Port Measurement Range 146 to 2498 F 99 to 1370 C K Port Measurement...

Page 12: ...ke accurate measurements if there is glass or plastic between it and the target Clean the infrared sensor lens Fig 1 Callout B often but never use a solvent Abrupt temperature changes will cause conde...

Page 13: ...ized service center freight prepaid and insured Acceptance of the exclusive repair and replacement remedies described herein is a condition of the contract for purchase of this product In no event sha...

Page 14: ...luminum polished plate 0 05 Aluminum rough plate 0 06 Aluminum oxidized 0 15 Aluminum surfaced roofing 0 22 Tin bright tinned iron sheet 0 04 Nickel wire 0 10 Lead 99 95 pure unoxidized 0 06 Copper 0...

Page 15: ...2 Copper scraped shiny not mirrored 0 07 Cooper plate heavily oxidized 0 78 Enamel white fused on iron 0 90 Formica 0 94 Brick red rough 0 93 Brick silica unglazed rough 0 80 Concrete 0 94 Glass smoot...

Page 16: ...431 6100 FAX 212 431 6499 TOLL FREE 800 697 8665 e mail sales generaltools com www generaltools com IRT659K User s Manual Specifications subject to change without notice 2013 GENERAL TOOLS INSTRUMENTS...

Reviews: