General INVERTER AOH34PEAM4 Operating Manual Download Page 20

En-19

Acoustic Noise Information : The maximum sound pressure level is less than 70 dB (A) for both indoor unit and outdoor

unit.
According to IEC 704-1 and ISO 3744.

MODEL

INDOOR UNIT

ASH12PMACW

ASH9PMACW

OUTDOOR UNIT

AOH34PEAM4

TYPE

HEAT&COOL MULTI SPLIT TYPE (REVERSE CYCLE)

POWER

220-240 V~  50 Hz

220-240 V~  50 Hz

OPERATING INDOOR UNIT

4 UNITS

4 UNITS

COOLING

CAPACITY

[kW]

10.2-10.2

9.8-9.8

POWER INPUT

[kW]

3.90-3.96

3.84-3.88

CURRENT

[A]

17.8-16.5

17.5-16.2

ENERGY EFFICIENCY RATIO

2.62-2.58

2.55-2.53

HEATING

CAPACITY

[kW]

11.7-12.0

11.3-11.6

POWER INPUT

[kW]

4.00-4.27

4.00-4.27

CURRENT

[A]

18.2-17.8

18.2-17.8

MAX. PRESSURE

[kPa]

3,000

REFRIGERANT [R407C]

[g]

3,600

DIMENSIONS & WEIGHT (NET)

INDOOR UNIT

HEIGHT

260 mm

260 mm

WIDTH

815 mm

815 mm

DEPTH

168 mm

168 mm

WEIGHT

8 kg

8 kg

OUTDOOR UNIT

HEIGHT

1,152 mm

WIDTH

940 mm

DEPTH

370 mm

WEIGHT

116 kg

SPECIFICATIONS

Summary of Contents for INVERTER AOH34PEAM4

Page 1: ...URE REFERENCE FUJITSU GENERAL LIMITED E nglis h OPE R ATING MANUAL P N9367998012 HEAT COOL MODEL REV ERS E CYCLE INDOOR UNIT AS H9PMACW AS H12PMACW OUTDOOR UNIT AOH34PEAM4 OPERATING MANUAL ROOM AIR CONDITIONER MULTI S PLIT TYPE 4 ROOMS ...

Page 2: ...nditioner directly to water Do not operate the air conditioner with wet hands Do not pull power supply cord Turn off power source when not using the unit for extended periods Check the condition of the installation stand for damage Do not place animals or plants in the direct path of the air flow Do not drink the water drained from the air conditioner Do not use in applications involving the stora...

Page 3: ...NIT The WIRELESS REMOTE CONTROL UNIT allows convenient control of air conditioner operation SWING OPERATION The Air Flow Direction Louvers swings automatically up and down so that the air speeds to every nook and corner of your room REMOVABLE INTAKE GRILLE The indoor unit s INTAKE GRILLE can be removed for easy cleaning and maintenance MILDEW RESISTANT FILTER The AIR FILTER has been treated to res...

Page 4: ...g 2 Fig 3 Fig 4 Fig 8 To facilitate explanation the accompanying illustra tion has been drawn to show all possible indicators in actual operation however the display will only show those indicators appropriate to the current op eration Fig 7 ...

Page 5: ... Remote Control Unit Display Fig 8 U Transmit Indicator V Clock Display W Operating Mode Display X Timer Mode Display Y Fan Speed Display Z Temperature Set Display Timer Set Indicator Temperature Set Indicator Fig 1 Indoor Unit 1 Operating Control Panel Fig 2 2 POWER Switch 3 MANUAL AUTO button 4 Remote Control Signal Receiver 5 Indicator Lamps Fig 3 6 OPERATION Indicator Lamp red Lights when unit...

Page 6: ...perating range About 7 meters When a signal is properly received by the air conditioner a beeping sound will be heard If no beep is heard press the remote control unit button again Remote Control Unit Holder PREPARATION CAUTION Take care to prevent infants from accidentally swallowing batteries When not using the remote control unit for an extended period remove the batteries to avoid possible lea...

Page 7: ... setting range AUTO Standard temperature setting 2 C Heating 16 to 30 C Cooling Dry 18 to 30 C The thermostat cannot be used to set room temperature during the FAN mode the temperature will not appear on the remote control unit s display About three seconds later the entire display will reappear The thermostat setting should be considered a standard value and may differ somewhat from the actual ro...

Page 8: ... accompanying table Also depending on the operating mode the room temperature setting will cause the standard temperature to be set as shown Actual Room Operating Mode Thermostat Setting Temperature standard setting 30 C or above Cooling 27 C 27 to 30 C Cooling 26 C 24 to 27 C Dry 24 C 22 to 24 C Monitor Below 22 C Heating 23 C The operating mode and standard thermostat settings are selected autom...

Page 9: ...itioner will operate at very low fan speed for about 3 to 5 minutes after which it will switch to the selected fan set ting This period of time is provided to allow the indoor unit to warm up before begin full operation When the room temperature is very low frost may form on the outside unit and its performance may be reduced In order to remove such frost the unit will automatically enter the defr...

Page 10: ...imer and ON timer operations in a single sequence The sequence can involve one transition from OFF timer to ON timer or from ON timer to OFF timer within a twenty four hour period The first timer function to operate will be the one set nearest to the current time The order of operation is indicated by the arrow in the Remote Control Unit s display OFF ON or OFF ON One example of PROGRAM timer use ...

Page 11: ...uring Timer Operation Press the START STOP button About the SLEEP timer To prevent excessive warming or cooling during sleep the SLEEP timer function automatically modifies the thermostat set ting in accordance with the time setting When the set time has elapsed the air conditioner completely stops During Heating operation When the SLEEP timer is set the thermostat setting is automatically lowered...

Page 12: ... from the air conditioner During the Cooling and Dry modes if the Air Flow Direction Louvers are left in the range 5 to 7 for more than 30 minutes they will au tomatically return to position 4 When used in a room with infants chil dren elderly or sick persons the air direction and room temperature should be considered carefully when making settings Vertical Air Direction Adjustment Press the AIR F...

Page 13: ...eration is con tinued at the lowest downward range for more than 30 minutes the unit will automatically switch the swing range to the horizontal flow range to prevent the condensation of moisture on the outlet The SWING operation may stop temporarily when the air conditioner s fan is not operating or when operating at very low speeds MANUAL AUTO OPERATION Use the MANUAL AUTO operation in the event...

Page 14: ...turned properly to their holes in the panel 2 Close the intake grille For purposes of example the illustration shows the unit without intake grille installed Dust can be cleaned from the air filter either with a vacuum cleaner or by washing the filter in a solution of mild de tergent and warm water If you wash the filter be sure to allow it to dry thoroughly in a shady place before rein stalling I...

Page 15: ...rately sold replacement air clean ing filters type APS 02F and install them 1 Open the intake grille and remove the air filters 2 Replace them by two new air cleaning filters 1 Remove the old air cleaning filters in reverse order of their installation 2 Install in the same way as for installation of the air cleaning filter set 3 Install the two air filters and close the intake grille In regard to ...

Page 16: ...from the indoor unit This smell is the result of room smells furniture tobacco etc which have been taken into the air conditioner During Cooling or Dry operation a thin mist may be seen emitted from the indoor unit This results from the sudden Cooling of room air by the air emitted from the air conditioner resulting in condensation and misting During Heating operation the outdoor unit s fan may st...

Page 17: ...tely stop operation turn off the circuit breaker and consult authorized service personnel OPERATING TIPS Heating Performance This air conditioner operates on the heat pump principle absorbing heat from outdoor air and transferring that heat indoors As a result the operating performance is reduced as outdoor air temperature drops If you feel that insuffi cient heating performance is being produced ...

Page 18: ...se of other electrical appliances electric shaver etc or nearby use of a wireless radio transmitter may cause the air conditioner to malfunction In this event temporarily disconnect the Power Supply Plug reconnect it and then use the remote control unit to resume operation The air conditioner power has been interrupted by a power failure The air conditioner will then restart automatically in its p...

Page 19: ... the indoor unit is instructed to do an operating mode that it cannot perform the OPERATION indicator lamp red on the indoor unit will flash 1 second on 1 second off and the unit will go into the standby mode Heating mode and cooling mode or dry mode Heating mode and fan mode Operation can be done in the following different operat ing modes Cooling mode and dry mode Cooling mode and fan mode Dry m...

Page 20: ...DOOR UNIT 4 UNITS 4 UNITS COOLING CAPACITY kW 10 2 10 2 9 8 9 8 POWER INPUT kW 3 90 3 96 3 84 3 88 CURRENT A 17 8 16 5 17 5 16 2 ENERGY EFFICIENCY RATIO 2 62 2 58 2 55 2 53 HEATING CAPACITY kW 11 7 12 0 11 3 11 6 POWER INPUT kW 4 00 4 27 4 00 4 27 CURRENT A 18 2 17 8 18 2 17 8 MAX PRESSURE kPa 3 000 REFRIGERANT R407C g 3 600 DIMENSIONS WEIGHT NET INDOOR UNIT HEIGHT 260 mm 260 mm WIDTH 815 mm 815 m...

Reviews: