WARRANTY

INFORMATION

General Tools & Instruments’ (General’s)
EP8709 Calibratable 4-Function Thermo-
Hygrometer is warranted to the original
purchaser to be free from defects in
material and workmanship for a period of
one year. Subject to certain restrictions,
General will repair or replace this
instrument if, after examination, the
company determines it to be defective in
material or workmanship.

This warranty does not apply to damages
that General determines to be from an
attempted repair by non-authorized
personnel or misuse, alterations, normal
wear and tear, or accidental damage. The
defective unit must be returned to General
Tools & Instruments or to a General-
authorized service center, freight prepaid
and insured.

Acceptance of the exclusive repair and
replacement remedies described herein is a
condition of the contract for purchase of this
product. In no event shall General be liable
for any incidental, special, consequential or
punitive damages, or for any cost, attorneys’
fees, expenses, or losses alleged to be a
consequence of damage due to failure of, or
defect in any product including, but not
limited to, any claims for loss of profits.

15

Summary of Contents for EP8709

Page 1: ...O HYGROMETER USER S MANUAL EP8709 Please read this manual carefully and thoroughly before using this product 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us...

Page 2: ...Operating Maintenance Tips 14 Warranty Information 15 Return for Repair Policy 16 INTRODUCTION Thank you for purchasing General Tools Instruments EP8709 Calibratable 4 Function Thermo Hygrometer Plea...

Page 3: ...Condensed water is called dew when it forms on a solid surface Another way to think of the dew point is as an air saturation temperature associated with relative humidity RH A high RH value indicates...

Page 4: ...tch 20 minute Auto Power Off function Low battery indicator WHAT S IN THE BOX The EP8709 comes fully assembled in a box along with a sensor protection cap a 9V battery and this user s manual PRODUCT O...

Page 5: ...ndicators and physical structures A Humidity and temperature sensors B LCD C Power on off button D F C button E WBT wet bulb temperature button F DEW button G HOLD button H MAX MIN button I Battery co...

Page 6: ...w battery icon B Data hold indicator C Maximum reading indicator D Minimum reading indicator E C indicator F F indicator G Wet bulb temperature indicator H Dew point temperature indicator I Temperatur...

Page 7: ...et inside the compartment The terminals of the battery and the socket mate in only one way with the smaller male terminal plugging into the larger female terminal 3 Replace the battery compartment cov...

Page 8: ...ding will be accompanied by the symbol WBT at its left To return to displaying ambient temperature press the WBT button again By default the EP8709 displays ambient dew point and wet bulb temperatures...

Page 9: ...power off the EP8709 press and hold the button for at least 3 seconds TRACKING MIN AND MAX LEVELS After being powered on the EP8709 automatically operates in Recording mode for the purpose of tracking...

Page 10: ...eadout Exiting Min Max mode clears the Min Max memory and begins a new measurement session CALIBRATING THE METER Your EP8709 was calibrated at the factory so its measurements should remain within thei...

Page 11: ...ction disabled rotate the sensor protection cap to open its three vents and expose the humidity sensor to the environment 2 Press and hold the DEW and F C buttons at the same time and then release the...

Page 12: ...s cap The fit should be tight with no air leaking into the bottle 7 Leave the meter upside down in the 75 salt bottle for at least 40 minutes The calibration to 75 is fully automatic and requires no...

Page 13: ...RH Measurement Accuracy 3 from 5 to 95 RH RH Measurement Resolution 0 1 Response Time 80 seconds Display Size 1 7 in 43mm diagonal Current Consumption 15mA Battery Life 60 hours typical Dimensions of...

Page 14: ...and temperature sensors after each measurement session rotate the sensor protection cap to close its three vents Do not operate the EP8709 in the presence of a flammable or explosive gas or near an ar...

Page 15: ...ttempted repair by non authorized personnel or misuse alterations normal wear and tear or accidental damage The defective unit must be returned to General Tools Instruments or to a General authorized...

Page 16: ...nter at this address General Tools Instruments 75 Seaview Drive Secaucus NJ 07094 212 431 6100 Remember to include a copy of your proof of purchase your return address and your phone number and or e m...