General DTH3007SD User Manual Download Page 9

on the top line, a value in the middle, and below it the letter “P” on the left and a number
from 1 to 99 on the same line to the right. The number indicates the position on the SD
card that will be used to store manually logged data.

Now press the LOGGER 

button. This will cause the beeper to sound and the term

“LOGGER” to briefly appear at the upper right of the display. As in automatic datalogging
mode, in this mode the instrument is storing measurements and their time stamps on 
the SD card.

In manual datalogging mode, however, measurements are stored continuously (with a
sampling time of zero), and their locations on the card can be changed.

5. To change the storage location of manually logged data

, press the SET 

button

once; this causes the “P” to disappear from the left side of the display and the value on
its line to begin flashing. Once the flashing begins, you can use the SET 

and LOGGER

buttons to change the flashing value to any number between 1 and 99. Once you have

chosen the storage location, press the REC/ENTER button to save the setting. This causes
the value to stop flashing and the “P” to return.

6. To end manual datalogging

, press the REC/ENTER button and hold it for at least three

seconds. This action causes the “REC” message to disappear from the top line of the
display.

TRANSFERRING DATA
FROM THE SD CARD 
TO A COMPUTER

After automatic or manual
datalogging of measurements,
remove the SD card from the
instrument and plug it into your
computer either directly (if it has 
an SD card slot) or through an 
SD card reader.

Because the files containing the
time-stamped data logs have the
extension .xls, they open in
Microsoft’s Excel application. 
Figures 2 and 3 show two kinds of
Excel presentations: a data-only
screen and a graphics-only screen.

9

Fig. 2. Typical Excel data-only screen

Fig. 3. Typical Excel graphics-only screen

Summary of Contents for DTH3007SD

Page 1: ...DTH3007SD USER S MANUAL THERMOMETER HUMIDITY METER WITH DATALOGGING SD CARD Please read this manual carefully and thoroughly before using this product ...

Page 2: ...e 4 5 Setup 5 7 Normal Operation 7 8 Holding and Storing Measurements 8 Automatic vs Manual Datalogging 8 9 Transferring Data from the SD Card to a Computer 9 Specifications 10 Maintenance Troubleshooting Tips 10 11 Optional Accessories 11 Warranty Information 11 Return for Repair Policy 11 2 ...

Page 3: ... of the portability reliability and large storage capacities that SD memory cards offer Measurements can be made automatically at any sampling rate between one second and one hour After the instrument time stamps and stores the measurements on an SD card plugged into it a process called datalogging the user can remove the card and plug it into a laptop or desktop computer either directly or via a ...

Page 4: ... case See the Optional Accessories section of this manual for more details Figure 1 shows all of the controls and indicators on the front right side back top and bottom of the DTH3007SD It also shows the main components of the included temperature humidity probe Familiarize yourself with the positions and functions of these controls indicators and connectors before moving on to the setup procedure...

Page 5: ...e display has stabilized perform the following eight setup steps in the order presented 3 Set the date and time Press the SET button callout 1 5 and hold it for at least five seconds until the word dAtE appears in the center of the display along with the flashing value 00 00 00 at the lower left above yy mm dd Set the current year by pressing the SET or LOGGER button repeatedly until the correct v...

Page 6: ... yES over the word bEEP Press the SET button until the desired setting yES or no is displayed and then press the REC ENTER button to store the selection as the default 7 Select the thermocouple type Once the beep sound has been enabled or disabled the lower part of the display will show the term tYPE Press the SET or LOGGER button until your thermocouple s type K or J appears on the display Then p...

Page 7: ...sed again By default the DTH3007SD uses Celsius units for temperature measurements To make Fahrenheit units the default perform Step 8 of the setup procedure 2 To measure temperature and humidity simultaneously seat the temperature humidity probe plug callout 1 17 of Fig 1 in its socket callout 1 7 on the top of the instrument Then press the FUNC HOLD NEXT button until the display shows the term r...

Page 8: ...red during the last session 3 To exit recording mode press the REC ENTER button and hold it for at least three seconds until the term REC disappears from the top line of the display The display will then revert to showing the current reading AUTOMATIC VS MANUAL DATALOGGING The DTH3007SD can automatically log data at a user selected sampling period from 1 second 3 600 seconds one hour To view the s...

Page 9: ...to begin flashing Once the flashing begins you can use the SET and LOGGER buttons to change the flashing value to any number between 1 and 99 Once you have chosen the storage location press the REC ENTER button to save the setting This causes the value to stop flashing and the P to return 6 To end manual datalogging press the REC ENTER button and hold it for at least three seconds This action caus...

Page 10: ...rature unit Storable recallable readings Maximum minimum SD card capacity 1 GB to 16 GB Operating temperature 32º to 122ºF 0º to 50ºC Operating relative humidity 0 to 85 Power source 6 Alkaline AA batteries or optional 9 VDC AC adapter Power consumption 3 5 mADC normal operation with backlight off and SD card not saving data 28 mADC with backlight on and card saving data 40 mADC with backlight on ...

Page 11: ...d repair by non authorized personnel or misuse alterations normal wear and tear or accidental damage The defective unit must be returned to General Tools Instruments or to a General authorized service center freight prepaid and insured Acceptance of the exclusive repair and replacement remedies described herein is a condition of the contract for purchase of this product In no event shall General b...

Page 12: ...1 6100 FAX 212 431 6499 TOLL FREE 800 697 8665 e mail sales generaltools com www generaltools com DTH3007SD User s Manual Specifications subject to change without notice 2010 GENERAL TOOLS INSTRUMENTS NOTICE WE ARE NOT RESPONSIBLE FOR TYPOGRAPHICAL ERRORS MAN DTH3007SD 12 03 10 ...

Reviews: