USING THE LEAK SIZE INDICATOR AND SENSITIVITY SETTINGS

Once the CGD900 has been started up, the digital leak size indicator
normally remains off (the display is blank). But once the instrument de-
tects a leak, a number from 1 to 9 is displayed in the window—regard-
less of the unit’s sensitivity setting.

The number displayed reflects the concentration of combustible gas
sensed. The maximum value is displayed when the tip of the probe is
at the source of the leak. Try switching between different sensitivity set-
tings while moving the probe until the highest number appears.

When  the  unit  has  reached  the  Ready  state,  the  unit  automatically
 defaults to the normal sensitivity level (the green LED labeled NORM is
 illuminated). To raise the sensitivity level, press the SENS. button once;
this lights the red LED labeled HI. To lower the sensitivity level, press
the SENS. button again; this lights the yellow LED labeled LO.

USING THE LEAK TEST VIAL

The CGD900 ships with a leak test vial that lets you check whether the
instrument is working properly. To perform this test:

• Remove the plastic cap from the leak test vial (it pops off,

rather than unscrews).

• Turn the instrument on and wait for it to heat the sensor

(the display goes blank and the green LED labeled NORM
illuminates).

• Place the tip of the probe close to the small hole in the top

of the leak test vial. If the unit is working properly, the unit’s
beep rate should increase and the digital leak size indicator
should display a number between 4 and 6. If you do not get
these readings, you should replace the sensor (see p.6).

NOTE: 

Always remember to replace the plastic seal cap

on the leak test vial after completing this test. Replace
the leak test vial when its contents no longer appear
green.

5

CGD900 Manual_FINAL2_091410:Layout 1  9/14/10  1:32 PM  Page 5

Summary of Contents for CGD900

Page 1: ...ed In MetHane aIr only Please read this manual carefully and thoroughly before using this product CGD900 Manual_FINAL2_091410 Layout 1 9 14 10 1 32 PM Page 1 99 Washington Street Melrose MA 02176 Phon...

Page 2: ...4 Operation Instructions 4 5 Maintenance Troubleshooting and Customer Service 6 Changing the batteries 6 Replacing the sensor 6 Specifications 7 Replacement Parts and Supplies 7 Warranty Information...

Page 3: ...u decide whether it is large enough to be worth plugging The read ing which is independent of the unit s sensitivity level rises and falls with the amount of combustible gas sensed at the end of the C...

Page 4: ...the on off button once to turn on the unit and again to turn it off 2 WARM UP Once the unit has been turned on it automatically begins heating the sensor During warm up the digital leak size indicato...

Page 5: ...LED labeled HI To lower the sensitivity level press the SENS button again this lights the yellow LED labeled LO USING THE LEAK TEST VIAL The CGD900 ships with a leak test vial that lets you check whet...

Page 6: ...sensor which has four leads Finally install the new sensor by aligning the notch in the sensor s socket with the raised tab on the socket holder see figure NOTE Do not force the sensor into the socke...

Page 7: ...ument and 1 year for the sensor PARTIAL LIST OF DETECTABLE GASES AND VAPORS Methane Propane Ethane Butane Hydrogen Ethylene Ethanol Isobutane NOL Gasoline fumes Acetylene Methyl ether Ammonia Hydrogen...

Page 8: ...ized personnel or misuse alterations normal wear and tear or accidental damage The defective unit must be returned to General Tools Instruments or a General au thorized service center freight prepaid...

Page 9: ...ss Remember to include a copy of your proof of purchase your return address and your phone number and or e mail address The CGD900 Combustible Gas Leak Detector is warranted to be free of defects in m...

Page 10: ...________________________________________ ____________________________________________________________ ____________________________________________________________ _____________________________________...

Page 11: ...________________________________________ ____________________________________________________________ ____________________________________________________________ _____________________________________...

Page 12: ...e NOTICE NOT RESPONSIBLE FOR TYPOGRAPHICAL ERRORS 2010 GENERAL TOOLS INSTRUMENTS 9 10 CGD900 Manual_FINAL2_091410 Layout 1 9 14 10 1 32 PM Page 12 99 Washington Street Melrose MA 02176 Phone 781 665 1...

Reviews: