General ASG9UI-LM Operating Manual Download Page 6

En-6

OPERATING MANUAL

Care and Cleaning

 

CAUTION

• Before cleaning the indoor unit, be sure to turn it off and all the power supply has been disconnected. 
• Before starting operation, make sure that the intake grille has been shut completely. Incomplete closing of the intake grille might have an 

effect on the proper working or performance of the air conditioner.

• Do not touch the aluminum 

fi

 ns of heat exchanger built-in the indoor unit to avoid personal injury when you  maintain the unit.

• Do not expose the indoor unit to liquid insecticides or hair sprays.
• Do not stand on slippery, uneven or unstable surfaces when you maintain the unit.

Daily care

When cleaning the indoor unit body, mind the following:

• Do not use water hotter than 40 °C.
• Do not use scouring cleanser, volatile solvents such as benzene or 

thinner.

• Wipe the unit gently by using soft cloth.

 Cleaning the intake grille

1

  Open the intake grille in direction of the arrow 

a

. While gently 

pressing the left and right mounting shafts of the intake grille 
outward 

b

, remove the intake grille in direction of the arrow 

c

.

a

a

b

c

b

c

2

  Wash the intake grille gently with water or wipe it gently with a 

soft cloth moisten with warm water.

 

Then wipe it with a dry and soft cloth.

3

  While holding the grille horizontal, set the left and right mounting 

shafts into the pillow blocks at the top of the panel 

a

. To latch 

each shaft properly, insert the shaft until it snaps.

 

Then close the intake grille 

b

.

a

a

b

b

4

  Press 4 places on the intake grille to close it completely.

  Cleaning the air 

fi

 lters

Mind that you have a periodical cleaning of the air 

fi

 lters to prevent 

reducing the operation ef

fi

 ciency of the product. 

Using of clogged air 

fi

 lter with dust will lower the product performance, 

and may cause air

fl

 ow reduction or increase of operating noise. 

Clean the air 

fi

 lters once every 2 weeks under normal use.

1

  Open the intake grille.

 (Refer 

to 

a

 of step 1 in “Cleaning the intake grille”.)

2

  While holding the intake grille with your hand, pull up the handle 

of the 

fi

 lter in direction of the arrow and release the 2 claws 

b

.

Then pull the 

fi

 lter out with gently sliding it downward 

c

.

a

b

b

a

c

3

  Filter holder and air cleaning 

fi

 lter are attached on the rear side 

of the air 

fi

 lter. Remove them from the air 

fi

 lter by unlatching each 

corner of the 

fi

 lter holder 

d

.

d

d

d

d

4

  Remove dust by using a vacuum cleaner or by washing the 

fi

 lter.

When you wash the 

fi

 lter, use neutral household detergent and 

warm water.
After rinse the 

fi

 lter well, dry it throughly in a shaded place before 

you reinstall it.

5

  Attach the air cleaning 

fi

 lter and the 

fi

 lter holder to each air 

fi

 lter.

6

  Attach the air 

fi

 lter with aligning both side of the 

fi

 lter with the front 

panel, and push in the 

fi

 lter fully.

Note:

 

Make sure that 2 claws are 

fi

 rmly snapped to the guide holes on 

the panel.

7

  Close the intake grille 

fi

 rmly.

(Refer to step 4 in “Cleaning the intake grille”.)

9333003009_OM.indb   6

9333003009_OM.indb   6

1/22/2013   10:12:02 AM

1/22/2013   10:12:02 AM

Summary of Contents for ASG9UI-LM

Page 1: ...oil such as a factory or area containing a large amount of splashed oil or steam such as a kitchen Do not start or stop the operation of this product by inserting or pulling out the power plug or by turning on or off the circuit breaker Do not use inflammable gases near the unit Do not expose yourself directly to the cooling airflow for many hours Do not insert your fingers or any other objects in...

Page 2: ...2 1 3 2 1 4 In SWING operation power diffuser does not move 6 Drain hose 7 Remote control signal receiver CAUTION For appropriate signal transmission between remote controller and the indoor unit keep the signal receiver away from following items Direct sunlight or other strong light Flat panel television screen In rooms with instantaneous fluorescent lights such as in verter type ones the signal ...

Page 3: ... shorten replace the batteries and press RESET button You can quickly start the operation with following 3 steps Remote Controller Overview and Operations 1 START STOP button 2 MODE button Switches operation mode in following order AUTO COOL DRY FAN HEAT Notes in HEAT mode At the beginning of the operation the indoor unit operates at very low fan speed for about 3 5 minutes for preparation and the...

Page 4: ...r stopping In FAN mode either of swing direction 1 3 or 4 7 is performed in accordance with the vertical airflow direction previously set before you start the SWING operation Remote Controller Overview and Operations 10 SET button Adjusts the vertical airflow direction See page 5 11 SLEEP timer button Activates the SLEEP timer that helps you to fall asleep comfortably with gradual temperature cont...

Page 5: ...of the product For frost protection a microcomputer controlled automatic defrost function is equipped in this air conditioner If frost forms the air conditioner will temporarily stop and defrost circuit will operate briefly maximum of 15 minutes OPERATION indicator on the indoor unit blinks during this operation If frost forms on the outdoor unit after the heating operation the outdoor unit will s...

Page 6: ...rt the shaft until it snaps Then close the intake grille b a a b b 4 Press 4 places on the intake grille to close it completely Cleaning the air filters Mind that you have a periodical cleaning of the air filters to prevent reducing the operation efficiency of the product Using of clogged air filter with dust will lower the product performance and may cause airflow reduction or increase of operati...

Page 7: ...he deodorizing effect by damage 4 Rinse the filter well with water flow 5 Dry the filter throughly in shaded place 6 Reinstall the deodorizing filter to the indoor unit Replace the filter once every 3 years under normal use After extended non use of the unit If you have shut down the indoor unit for 1 month or more perform the FAN operation for half a day to dry the internal parts throughly before...

Page 8: ...ERATION indicator is flashing 5 In DRY mode the indoor unit operates at low fan speed to adjust the room humidity and may stop from time to time When the fan speed is set to QUIET the fan rotates at very low speed and the airflow is reduced In COOL mode the indoor unit fan may stop from time to time when the outdoor unit is stopped 3 When monitoring operation is performed in AUTO mode the fan rota...

Reviews: