General AOH12UGBC Operating Manual Download Page 13

En-12

TROUBLESHOOTING

WARNING!

Symptom

Doesn’t operate immedi-
ately:

Noise is heard:

Smells:

Mist or steam are
emitted:

Airflow is weak or stops:

Water is produced from
the outdoor unit:

Problem

If the unit is stopped and then immediately started again, the com-
pressor will not operate for about 3 minutes, in order to prevent
fuse blowouts.

Whenever the Power Supply Plug is disconnected and then re-
connected to a power outlet, the protection circuit will operate for
about 3 minutes, preventing unit operation during that period.

During operation and immediately after stopping the unit, the
sound of water flowing in the air conditioner’s piping may be
heard. Also, noise may be particularly noticeable for about 2 to 3
minutes after starting operation (sound of coolant flowing).

During operation, a slight squeaking sound may be heard. This is
the result of minute expansion and contraction of the front cover
due to temperature changes.

During Heating operation, a sizzling sound may be heard occasional.
This sound is produced by the Automatic Defrosting operation.

Some smell may be emitted from the indoor unit. This smell is
the result of room smells (furniture, tobacco, etc.) which have
been taken into the air conditioner.

During Cooling or Dry operation, a thin mist may be seen emitted
from the indoor unit. This results from the sudden Cooling of
room air by the air emitted from the air conditioner, resulting in
condensation and misting.

During Heating operation, the outdoor unit’s fan may stop, and
steam may be seen rising from the unit. This is due to Automatic
Defrosting operation.

When Heating operation is started, fan speed is temporarily very
low, to allow internal parts to warm up.

During Heating operation, if the room temperature rises above
the thermostat setting, the outdoor unit will stop, and the indoor
unit will operate at very low fan speed. If you wish to warm the
room further, set the thermostat for a higher setting.

During Heating operation, the unit will temporarily stop opera-
tion (between 7 and 15 minutes) as the Automatic Defrosting mode
operates. During Automatic Defrosting operation, the OPERATION
indicator lamp will flash.

The fan may operate at very low speed during Dry operation or
when the unit is monitoring the room’s temperature.

During SUPER QUIET operation, the fan will operate at very low
speed.

In the monitor AUTO operation, the fan will operate at very low
speed.

During Heating operation, water may be produced from the out-
door unit due to Automatic Defrosting operation.

See Page

13

13

13

5

5

5

13

NORMAL

FUNCTION

In the event of a malfunction (burning smell, etc.), immediately stop operation, disconnect the
Power Supply Plug, and consult authorized service personnel.
Merely turning off the unit’s power switch will not completely disconnect the unit from the
power source. Always be sure to disconnect the Power Supply Plug or turn off your circuit
breaker to ensure that power is completely off.

Before requesting service, perform the following checks:

Summary of Contents for AOH12UGBC

Page 1: ...tandarder uppfyller de berörda produkterna föreskrifterna i de direktiv som anges här nedan Os seguintes produtos referenciados na lista abaixo estão em conformidade com as normas Соответствуя указанным стандартам данные изделия отвечают требованиям ниже перечисленных директив a EC Council Directive 73 23 EEC b EC Council Directive 89 336 EEC Place of Issue F R Germany Title of Authority General M...

Page 2: ...IOR Altura anchura profundidad 535 695 250 mm Peso 30 kg NETO PRESSIONE MASSIMA ASPIRAZIONE 1 160 kPa EMISSIONE 4 120 kPa REFRIGERANTE R410A 900 g DIMENSIONI E PESO APPARECCHIO INTERNO Altezza Larghezza Profondità 257 790 205 mm Peso 9 0 kg netti APPARECCHIO ESTERNO Altezza Larghezza Profondità 535 695 250 mm Peso 30 kg netti ΜΕΓΙΣΤΗ ΠΙΕΣΗ ΑΝΑΡΡΟΦΗΣΗ 1 160 kPa ΕΚΤΟΝΩΣΗ 4 120 kPa ΨΥΚΤΙΚΟ R410A 900 ...

Page 3: ...ent con trol of air conditioner operation SWING OPERATION The Air Flow Direction Louvers swings automatically up and down so that the air speeds to every nook and corner of your room REMOVABLE INTAKE GRILLE The indoor unit s Intake Grille can be removed for easy clean ing and maintenance MILDEW RESISTANT FILTER The AIR FILTER has been treated to resist mildew growth thus allowing cleaner use and e...

Page 4: ...button S FAN CONTROL button T START STOP button U AIR FLOW DIRECTION button V SWING LOUVER button W ACL button located inside battery compartment X TEST RUN button This button is used when installing the conditioner and should not be used un der normal conditions as it will cause the air conditioner s thermostat function to op erate incorrectly If this button is pressed during normal op eration th...

Page 5: ...mote control unit s operating range becomes appre ciably reduced replace the batteries and press the ACL button with the tip of a ballpoint pen or other small object Turn on the Power 1 Connect the Power Supply Plug Fig 1 D to an electri cal outlet in the case of a direct line connection turn on the circuit breaker Load Batteries R03 LR03 2 1 Press and slide the battery compartment lid on the re v...

Page 6: ...ual room temperature To Set the Fan Speed Press the FAN CONTROL button Fig 6 S Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About three seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when the temperature of the air issu...

Page 7: ...te at very low fan speed for about 3 to 5 minutes after which it will switch to the selected fan setting This period of time is provided to allow the indoor unit to warm up before begin full operation When the room temperature is very low frost may form on the outside unit and its performance may be reduced In order to remove such frost the unit will automatically enter the defrost cycle from time...

Page 8: ...e time while the ON TIMER mark on the remote control unit s display is flashing The flashing will continue for about 30 seconds 3 Press SET button Fig 6 Q to select ON TIMER opera tion The ON Timer mark will be shown on the remote control unit s dis play The Indoor Unit Timer Indicator Lamp green Will light It can not be used during OFF TIMER operation To Cancel the Timer Press the CANCEL TIMER bu...

Page 9: ...ifies the thermostat set ting in accordance with the time setting When the time has elapsed the air conditioner completely stops During Cooling Dry operation When the SLEEP timer is set the thermostat setting is auto matically raised 1 C every sixty minutes When the ther mostat has been raised a total of 2 C the thermostat set ting at that time is maintained until the set time has elapsed at which...

Page 10: ...tion Louvers are left in the heat ing range for more than 30 minutes they will automatically return to posi tion 3 When used in a room with infants chil dren elderly or sick persons the air direction and room temperature should be considered carefully when making settings Vertical Air Direction Adjustment Press the AIR FLOW DIRECTION button Fig 6 U Each time the button is pressed the air direction...

Page 11: ...O operation in the event the Remote Control Unit is lost or otherwise unavailable How To Use the Main Unit Controls Press the MANUAL AUTO button Fig 2 2 on the main unit control panel To stop operation press the MANUAL AUTO button once again Controls are located inside the Intake Grille When the air conditioner is operated with the controls on the Main Unit it will operate under the same mode as t...

Page 12: ...holes in the panel 2 Close the Intake Grille For purposes of example the illustration shows the unit without Intake Grille installed Dust can be cleaned from the Air Filter either with a vacuum cleaner or by washing the filter in a solution of mild detergent and warm water If you wash the filter be sure to allow it to dry thoroughly in a shady place before reinstalling If dirt is allowed to accumu...

Page 13: ...ioner resulting in condensation and misting During Heating operation the outdoor unit s fan may stop and steam may be seen rising from the unit This is due to Automatic Defrosting operation When Heating operation is started fan speed is temporarily very low to allow internal parts to warm up During Heating operation if the room temperature rises above the thermostat setting the outdoor unit will s...

Page 14: ...ION indicator lamp red will flash Heating Performance This air conditioner operates on the heat pump princi ple absorbing heat from outdoor air and transferring that heat indoors As a result the operating performance is reduced as outdoor air temperature drops If you feel that insufficient heating performance is being produced we recommend you use this air conditioner in conjunction with another k...

Page 15: ...e to prevent internal circuit damage Also during Cooling and Dry modes if the unit is used under conditions of lower temperature than those listed above the heat exchanger may freeze leading to water leakage and other damage Do not use this unit for any purposes other than the Cooling Dehumidifying and air circulation of rooms in ordinary dwellings If the unit is used for long periods under high h...

Reviews: