ERROR DISPLAY
2003.12.29 PRELIMINARY
12
The OPERATION, TIMER and SWING lamps operate as follows according to the error contents.
Error display
OPERATION TIMER
SWING
(RED)
(GREEN)
(ORANGE)
Error contents
Indoor unit circuit board error
Indoor unit room temperature sensor wire
opened
Indoor unit room temperature sensor wire
short circuited
Indoor unit piping sensor wire opened
Indoor unit piping sensor wire short circuited
Indoor unit fan error
2 times
2 times
3 times
3 times
6 times
:
Fast flashing
:
Slow flashing
:
Off