background image

10

Attach the collector bag by using the hooks on the unit 

to hold it in place 

D

. Use the belt clamp to attach the 

bag to the lower portion of the drum 

E

. Before tighten-

ing the clamp, make sure the metal strap is sitting in the 

groove on the lower portion of the drum to create an 

airtight seal between the drum and the bag.

If you have model 10-110CF (with canister filter) skip 

ahead to step #9.

Fit the upper bag support into the holes on the drum  

F

.

 Slip a belt clamp through the opening in the filter 

bag until it comes out through the hole at the other 

end 

G

. Use the belt clamp to attach the filter bag to 

the upper portion of the drum  

H

. Before tightening 

the clamp make sure the metal strap is sitting in the 

groove on the upper portion of the drum to create an 

airtight seal between the drum and the bag.

USE CAUTION AND WEAR GLOVES WHEN HANDLING  

METAL PARTS SUCH AS BELT CLAMPS, WHICH CAN CUT 

IF HANDLED CARELESSLY.

Basic assembly is now complete and your dust col-

lector is ready to be put into service. Once the unit is 

hooked up to an appropriate electrical connection, 

turn on the unit and check for air leaks around the 

bags or canister filter 

(model 10-110CF)

. If there is an air 

leak, peel off the backing of the adhesive foam gasket 

and stick it onto the drum, making sure the gasket is 

sitting in the appropriate groove.

STEP 10  - INSTALL THE FOAM GASKET  

(IF NEEDED)

If you have model 10-110 with filter bag skip ahead to step 

#10.

Fit the canister filter onto the drum as shown and use 

the belt clamp to hold the canister securely onto the 

drum.

Tip/Hint: To seat the canister on the rim of the drum, run a 

flat piece of wood (such as a ruler) between the drum and 

the black apron on the bottom of the canister I.

STEP 9 - FIT THE CANISTER FILTER ONTO THE DRUM

 

(#10-110CF  ONLY)

D

STEP 7 - INSTALL THE COLLECTOR BAG

E

STEP 8 - INSTALL THE FILTER BAG ON THE DRUM

 ( #10-110 only)

F

G

H

I

Summary of Contents for 10-110

Page 1: ...odels Safety switch with key prevents unit from being started when key is removed Heavy duty collection bags made from extra thick transparent recyclable plastic SPECIFICATIONS INLET DIAMETERS 1 6 152...

Page 2: ...riod of 24 months from date of purchase any genuine part or parts which upon examination prove to be defective in workmanship or material In order to obtain this warranty all defective parts must be r...

Page 3: ...rd 2 year Limited Warranty or under our Limited Lifetime Warranty all defective parts components or machinery must be returned freight or postage prepaid to General International or to a nearby distri...

Page 4: ...ng or with the power on 14 To avoid health hazards from vapors or dusts do not vacuum toxic material 15 Do not insert hands or fingers or any foreign objects into ventilation inlet and outlet openings...

Page 5: ...re proceeding TABLE MINIMUM GAUGE FOR CORD VOLTS 110 V MORE THAN 18 18 16 14 220 V AMPERE RATING NOT MORE THAN 0 6 10 12 6 10 12 16 16 16 16 12 16 14 14 14 12 12 25 ft 50 ft 50 ft 100 ft 100 ft 200 ft...

Page 6: ...S AND COMPONENTS 2 HP DUST COLLECTOR 10 110 or 10 110CF OR CONNECTOR DRUM COLLECTOR BODY W MOTOR ASS Y BASE PLATE HOSE INLET Y FITTING FILTER BAG 10 110 ONLY CANISTER FILTER 10 110CF ONLY COLLECTOR BA...

Page 7: ...E THAT ADEQUATE HEARING PRO TECTION IS USED AND THAT THE OVERALL SOUND LEVEL WITHIN THE WORKING ENVIRONMENT IS TAKEN INTO CONSIDERATION ADDITIONAL REQUIREMENTS FOR SETUP ASSEMBLY Flat piece of wood su...

Page 8: ...collector in your shop HOSES AND DUCTING RUNNING ALONG THE SHOP FLOOR BETWEEN MACHINERY CAN CAUSE USERS TO TRIP AND LEAD TO SERIOUS INJURY LAYING OUT A PLAN FOR THE PIPING For permanent installations...

Page 9: ...ket and place it over the opening of the connector Take the drum and proceed by placing it over the same opening STEP 4 ATTACH THE DRUM Note The vertical support rod has an angled end A to seat over t...

Page 10: ...S WHEN HANDLING METAL PARTS SUCH AS BELT CLAMPS WHICH CAN CUT IF HANDLED CARELESSLY Basic assembly is now complete and your dust col lector is ready to be put into service Once the unit is hooked up t...

Page 11: ...D REMOVE THE SWITCH KEY WHENEVER THE DUST COLLECTOR IS NOT IN USE PLACE IT IN A SAFE PLACE AND OUT OF THE REACH OF CHILDREN 11 This machine operates on 220 V single phase power M1 model only if you su...

Page 12: ...er filter may become clogged and affect airflow as well the overall efficiency of the unit Should you notice a drop in the efficiency or performance of the unit it may be a sign that it is time to cle...

Page 13: ...website at www general ca 4 to 2 1 2 Reducer 10 086 1 Micron Canister Filter 10 106C 4 x 10 Polyethylene Flexible Hose 10 410 4 x 50 heavy duty polyethylene flexible hose 10 130 Clear Plastic Collecto...

Page 14: ...28 17A 25 30 12 18 2 11A 10A 9 6A 13 5 29 4A 1 2 32 33 2 23 2 28 2 27 34 24 34 22 16 15 12 31 2 19 35 7A 26A 29A 36 14...

Page 15: ...0 19 CONNECTOR 1 22 10110 22 COLLECTOR BAG ITEM 10 120 1 23 10110 23 VERTICAL SUPPORT ROD 1 24 10110 24 DRUM 1 25 10110 25 GASKET 1 26A 10110 26A HANGER 1 27 10110 27 FILTER 1 28 10110 28 FOAM GASKET...

Page 16: ...P 3 4 1 10106C 31 CANISTER FIXING PLATE 2 10106C 32 BEARING 1206 2 10106C 35 FLAPPER 3 10106C 36 SPINDLE 1 PART DESCRIPTION SPEC QTY 10106C 38 ROUND HEAD SCREW M5X6 6 10106C 39 FIXING PLATE 2 10106C 4...

Page 17: ...17 Notes...

Page 18: ...Champ d Eau Montreal Quebec Canada H1P 1Y3 Tel 514 326 1161 Fax 514 326 5565 Parts Service Fax 514 326 5555 Order Desk orderdesk general ca www general ca MODEL 10 110 10 110CF 10 110CF 10 110 Follow...

Reviews: