GENERAL PUMP
A member of the Interpump Group
Formula 99S
Electric Pressure Washer
TROUBLESHOOTING
PROBLEM
CAUSE
SOLUTION
Pump running normally but
Pump sucking air
Check that hoses and fittings
pressure does not achieve
are air tight
rated values
Valves worn or dirty
Check, clean or replace
Unloader packing worn
Check and replace
Nozzle incorrect or worn
Check and replace
Worn piston packing
Check and replace
Dirty filter
Check and clean
Fluctuating pressure
Valves worn or stuck
Check, clean or replace
Pump sucking air
Check that hoses and fittings
are air tight
Worn piston packing
Check and replace
Dirty filter
Check and clean
Pressure drops after
Nozzle worn
Check and replace
period of normal use
Valves worn, dirty or stuck
Check, clean or replace
Unloader packing worn
Check, clean or replace
Worn piston packing
Check and replace
Dirty filter
Check and clean
Pump noisy
Pump sucking air
Check that hoses and fittings
are air tight
Valves dirty or worn
Check, clean or replace
Worn bearings
Check and replace if necessary
Water top hot
Reduce temperature
Dirty filter
Check and clean
Presence of water in oil
High humidity in air
Check and change oil twice as
often
Piston packing and oil seal worn
Check and replace
Water dripping from
Piston packing worn
Check and replace
under pump
The o-rings of piston guide or
Check and replace
retainer worn
Oil dripping
Oil seal worn
Check and replace
The motor does not start
The plug not well connected or
Check plug, cable and switch
when switched on
lack of power supply
When switching on the unit,
The main voltage is insufficient,
Check that the main power
the motor hums but does
lower than the minimum required
supply is adequate
not turn on
The pump is stuck or frozen
Check by turning the motor
manually as described in
instructions (page 4)
Incorrect extension cord
Check and replace
The motor stops
Tripped thermal overload due
Check that the main voltage
to overheating
corresponds to the specifications:
F-122, F-124, X-220, X230, X240
:
switch off the motor and let it cool
a few minutes
X117 & X161: wait a few minutes