1.  Press the Video button (movie camera icon) to begin recording. 

The  yellow  video  icon  (upper  right)  turns  read  while  recording 
and the elapsed timer (upper left) begins counting. 

2.  Press  the  Video  button  again  to  stop  recording.  The  red  video 

icon will return to yellow and the elapsed timer will reset to zero.  
The  hourglass  icon  is  shown  when  a  recording  (.avi)  is  being 
saved to the Flash Drive. 

3. 

The ‘X’ error symbol appears if the storage device does not have 

enough free space. 

4.  To view videos, press the UP arrow from the main display and a 

list of video recordings will appear. Use the arrows to highlight a 
video and press OK to view it. 

5.  The following features are available when viewing a video: 
6.  Short press of either arrow button jumps back to the beginning. 
7.  Long  press  of  a  button  fast-forwards  (UP)  or  fast-rewinds 

(DOWN). 

8.  Use OK to Pause or Resume. 
9.  Use ESC button to return to the main display. 
10.  The Video button opens the trash utility. Use arrows to highlight 

the check mark (delete video) or the ‘X’ (keep video). Press OK 

to complete function.  

Image Capturing, Viewing, and Deleting 

1.  Press the image button (camera icon) to take a snapshot of the 

screen.  The  yellow  icon  (upper  right)  will  briefly  turn  red  and 
return  to  yellow  when  the  snapshot  (.jpg)  has  been  stored  on 
the USB Flash Drive. The hourglass appears while the image is 
being saved. 

2.  The red error symbol will appear if the storage device does not 

have enough free space. 

3.  Press the UP arrow to open the image files. Use the arrow keys 

to scroll and use OK to open an image. The date and Time the 
image was taken is also shown. 

4.  Use the OK button to rotate the image (90° rotation with each 

press of the button). 

5.  Use  the  CAMERA  button  to  select  a  zoom  level  (from  1X  to 

10X). 

6.  Use  the  Video  button  to  open  the  trash  utility.  Use  the  arrow 

buttons  to  highlight  the  check  mark  (delete  image)  or  the 

‘X’ (keep image), and then press OK.

 

7.  Press ESC to return to the stored image list. Pres ESC again to 

return to the main display. 

Power Input 

Power input is located on the left side of the Command Module. Only 

operate the Micro-Scope2 with the 15 volt power supply supplied with 
monitor.  

Battery Charger

  

The internal 4 hr battery will power the Micro-Scope2 when AC power 

is not available. Recharging time varies depending upon air tempera-
tures and the condition of the battery. The battery does not have to be 
deep cycled, but the battery may have to be replaced over time de-

pending on usage and conditions. The battery can be recharged from 
either an AC outlet, or from an AC inverter outlet in your car or truck. 

Connect the appropriate cord for your charging method to the Com-
mand Module, then to the power source.  

Voice-Over Microphone 

This unit includes an internal microphone so you can add commentary 

to  your  videos.  The  Microphone  is  “live”  and  records  while  video  is 

recorded.  Audio  may  be  monitored  during  recording  by  inserting  an 
earphone into the jack on the left side on the monitor. Audio can be 

heard though the speaker in the Command Module during video play-
back.  

NOTE: The Gen-Eye Micro-Scope is equipped with an integral micro-
phone. The microphone is always on. Therefore, if you are recording 
video, please be aware that you are also recording audio. 

SET UP - COMMAND MODULE  

1.  To set up for the Probe rod, connect the 

Probe Rod to the connector at the top of the 
Command Module. 

2.  To set up for pipe inspection, mount the 

hand-held Command Module onto the reel 
by first threading the mounting ball with two 
lock washers into the back of the unit.  Then 

slide the mounting ball into the end of the extender and ball as-
sembly at the center of the reel. Adjust the Command Module for 
the desired viewing angle and tighten the knob on the extender. 

3.  Connect the Interface Cord form the reel to 

the connector at the top of the Command 
Module. 

4.  Insert flash drive into USB slot on the left 

side of the Command Module. 

5.  If using AC power, plug power adapter into 

the left side of the Command Module. If us-
ing 4 hr internal DC battery, make sure unit 
is fully charged. 

6.  Press the POWER button for 3 

 5 sec-

onds to turn the Command Module on. The 

Start-Up screen is shown briefly, followed 
by the Status screen for 5 seconds. 

The status screen shows the capacity of the flash drive and inter-
nal  battery.  If  the  command  Module  has  been  stored  for  a  long 

period of time the display might not have enough power to turn on. 
Use the power adapter to recharge the battery.  

NOTE:  Command  Module  is  shipped  without  a  charge. 

Charge  the  Command  Module  for  12  hours  or  overnight 
before first use.  

Video Recording, Viewing and Deleting 

Summary of Contents for Gen-Eye Micro-Scope2

Page 1: ...ars of trouble free profitable service However no machine is better than its op erator Read understand and follow all safety warnings and instructions provided with the product Failure to follow the warnings and instructions may result in electric shock and or serious injury Save all warnings and instructions for future reference SAVE THESE INSTRUCTIONS ...

Page 2: ...situation Use a UL approved tester to determine if the outlet is safe Do not operate power tools in explosive atmospheres such as in the presence of flamma ble liquids gases or dust Power tools create sparks which may ignite the dust or fumes Always wear safety glasses and rubber soled non slip shoes Use of this safety equip ment may prevent serious injury These instructions are intended to famili...

Page 3: ...ituations 5 Always wear safety glasses and rubber soled non slip shoes Dust mask non skid safety shoes hard hat or hearing protection must be used for appropriate conditions 6 Rubber glove inserts should be worn for health and safety reasons Sewer lines are unsanitary and may contain harmful bacteria 7 Check to make sure pipes are not electrically hot In some cases ground circuits may be returned ...

Page 4: ...od condition Using lighter cords can result in severe power loss and motor overheat ing 12 Be careful when inspecting drains where cleaning chemicals have been used Avoid direct contact with corrosive drain clean ers Drain cleaning chemicals can cause serious burns as well as damage the cable Neutralize or remove corrosive drain cleaners in the drain before starting the job 13 Do not operate machi...

Page 5: ...amming value Press to start stop video recording Increment a programming value Open the video trash utility from the video viewer Rotate the record image 90 degree While in live image mode press this bottom to set Brightness Contrast and Grey scale GEN EYE MICRO SCOPE2 COMMAND MODULE The Command Module should not be used in wet locations or in the rain as moisture may cause damage to the unit THE ...

Page 6: ...in menu Factory Default Reset and Firmware Version 1 From the main menu use the arrow buttons to scroll to the Fac tory Default icon and press OK to open it 2 There are three rows of options in this menu The top row is the Factory Default reset icon To revert to factory settings highlight this icon with the arrow buttons and pres the OK button 3 The middle row is the abort function Press OK with t...

Page 7: ...internal 4 hr battery will power the Micro Scope2 when AC power is not available Recharging time varies depending upon air tempera tures and the condition of the battery The battery does not have to be deep cycled but the battery may have to be replaced over time de pending on usage and conditions The battery can be recharged from either an AC outlet or from an AC inverter outlet in your car or tr...

Page 8: ...pe conditions In some cases white or lighter colored objects may cause the picture to flare or wash out If this happens simply adjust the light level until a good picture is achieved 8 Push the camera slowly and carefully during the inspection taking note of the pipe condition for possible hazards that may entangle or damage the camera on entry or retrieval 9 When negotiating a corner care should ...

Page 9: ...dule is turned up Check cable for possible breaks or intermittent open circuits by flexing the cable Disconnect main power and contact the factory service depart ment No Picture Lights OK Check Monitor power switch is ON Check to make sure the power source is live for 120 volt AC or that the battery is charged Check the interface cord for possible damage or intermittent problem by flexing the cabl...

Page 10: ... to fully recharge battery Cold weather can reduce battery life Keep unit warm in cold weather Do not charge the battery in extreme weather temperatures below 30 F or above 104 F When charging via DC you must use the AC inverter Battery is worn out and need to be replaced Disconnect the main power source and contact the factory ser vice department NOTE Command Module is shipped without a charge Ch...

Reviews: