GM8802F-2 Field Mounting Transmitter
GM8802-F2110101
9
4 Parameter table
Parameters in every channel are same, but also can be set individually.
4.1 Calibrate parameters
Parameters
Initial values
Range
Unit
1
0
,
1
,
2
,
3
Decimal point
0
0
,
1
,
2
,
3
,
4
Minimum division
2
1
,
2
,
5
,
10
,
20
,
50
Maximum capacity
10000
≤Mini division
×
50000
4.2 Operation parameters
Parameters
Initial
values
Range
Description
Filter grade
4
0-9
0
:
none
9
:
strongest
Stability range
2d
1-9d
If present weight change at
stability range in stability time, then
transmitter confirm the weight
value is stable.
Stability time
1.0S
0.1-1.0S
Zero-tracking
range
0d
0-9d
If present weight is at zero-tracking
range in zero-tracking time, the
transmitter track zero, but not track
zero when Zero-tracking range is
0
.
Zero-tracking
time
1.0S
0.5
,
1.0
,
1.5
,
2.0
Zeroing range
20%
1%-99%
Percent of maximum capacity.
Anti-vibration
parameters
4
0-99
0
means no anti-vibration function
www.zemicusa.info