GM7702 User Manual
- 38 -
D2
: overflow when zeroing
D3
: zero calibration is unstable.
D4
: zero voltage is too high.
D5
: zero voltage is too low.
D6
: gain voltage is unstable.
D7
: gain voltage is too large.
D8
: gain voltage is too low.
D9
: weight input is wrong.
D10
: calibration resolution is too low.
D11
: previous gain has not calibrated.
D12
: non weights for calibration
40017
0016
gross weight(floating-point data
)
40018
0017
40019-40020
0018-0019
Reserved (Allow to read value: 0)
Read & Write (write function code: 0x06, 0x10; read function code: 0x03.)
40021
0020
unit: (
0:g, 1:kg, 2:t,3:lb)
40022
0021
decimal point (0: 0 digit, 1: 1 digit, 2: 2 digits, 3: 3 digits, 4: 4
digits)
40023
0022
division(
1/ 2/ 5/ 10/ 20/ 50
)
40024
0023
max. capacity, write range (max. capacity
≤
division*100000)
40025
0024