background image

GENERAL SPECIFICATIONS

MITRA 110S is a wired room thermostat. The user can adjust the 

room  temperature  with  the  required  temperature  and  get  more 

comfortable and economic heating.

Precise Temperature Measurement                         Wired Connection

ON/OFF Control

MITRA 110S AND EQUIPMENTS

TECHNICAL DATA

ROOM THERMOSTAT

Room Thermostat Indicator LED Descriptions

ROOM THERMOSTAT PLACEMENT

Room Thermostat needs to be placed in the room which is used most 

frequently.For  instance;  living  room  or  lounge.Placing  the  Room 

Thermostat in a spot that have air circulation like entrance of a room 

or side of window should be avoided. Also anywhere close to heating 

units such as radiator, stove and spots which get direct sun lights 

would not be suitable. Room Thermostat needs to be located above 

the floor 150 cm height. Few trials may be made to find the most 

convenient spot.

BATTERY PLACEMENT

Before  starting,  power  off  the  device  connected  to  the  Room 

Thermostat and make sure that the energy is cut off.

As shown in the picture above, press the screwdriver forward from the 

space shown, bend the tabs and separate the front cover. Insert 2 new 

AAA alkaline batteries in the battery housing with the correct battery 

direction. Replace both batteries at the same time. Then align the 

front  part  of  your  Room  Thermostat  to  the  back  and  squeeze  it 

towards the back.

WARNING!

When the product is not used for a long period (more than 15 days), 

remove the batteries. Otherwise, malfunctions that may occur would 

be out of warranty. 
Please throw your dead batteries into the waste bin for batteries.

1

2

3

MITRA 110S

Room Thermostat

generallife.com.tr

85mm / 125mm / 24mm

3V DC (2 x AAA alkaline battery)

2A/30VDC (Resistive load)

0.5A/125VAC (Resistive load)

o

0.1 C

o

0.5 C

o

o

(5 C) – (35 C)

1 Year (2 x AAA)

o

o

(-10 C) – (+50 C)

o

o

(-20 C) – (+60 C)

MITRA 110S USER MANUAL

Dowels and

Screws

Alkaline

Battery

A

A

A

A

A

A

MITRA 110S

USER MANUAL

DIGITAL ROOM THERMOSTAT

Adjustment Knob

Indicator LED

The relay contact opens and the heating unit
stops working.
The relay contact closes and the heating unit
starts.

If it blinks once

If it blinks twice

min. 20 cm

150 cm

ROOM THERMOSTAT WIRING DIAGRAM

WARNING!

Operations inside the boiler or related to the electrical installation 

must be carried out by persons with professional competence.

ROOM THERMOSTAT WORKING LOGIC

Your Room Thermostat will start working from the moment you insert 

the batteries Your Room Thermostat measures the temperature of its 

environment every 5 seconds. If the ambient temperature rises 0.5 

degrees above the temperature you have set, your Room Thermostat 

will send a command to the Receiver and turn off the boiler , if it falls 

below 0.5 degrees, it turns on the boiler. Thus, it ensures that the 

ambient temperature remains within a certain range.

FREQUENTLY ASKED QUESTIONS

Is my Room Thermostat compatible with my boiler?

If  your  boiler  has  on-off  connections,  your  Room  Thermostat  is 

compatible. You can learn the information about your boiler from the 

boiler user manual or  your boiler service.

How will I connect my boiler with my Room Thermostat?

We recommend that the connection between your Room Thermostat 

and your boiler should be made by professionally qualified persons. 

2x0.75  mm  cable  is  sufficient  for  the  Room  Thermostat  -  boiler 

connection. 

Connect one end of the cable pair to the room thermostat connection 

terminals stated in the user manual of your boiler.

Connect the other end of the cable pair to COM and NO inputs of the 

terminal  inside  the  Room  Thermostat  as  shown  in  the  "ROOM 

THERMOSTAT WIRING DIAGRAM" section.

The direction of the cable ends does not matter.

COM

NO

ENGLISH

generallife.com.tr

DIGITAL ROOM THERMOSTAT

Dimensions ( H / L / W )

Operating Current

Relay NO Switching Current

Temperature Measurement

Accuracy

Operating Sensivity

Operating Temperature Range

Battery Life

Operating Temperature

Storage Temperature

Time

Heating

Unit Off

Heating

Unit On

Set

Temperature

Room

Temperature

o

22.0 C

o

22.5 C

o

21.5 C