Screen Indicators
ROOM THERMOSTAT PLACEMENT
Room Thermostat needs to be placed in the room which is used most
frequently. For instance; living room or lounge. Placing the Room
Thermostat in a spot that have air circulation like entrance of a room
or side of window should be avoided. Also anywhere close to
heating/cooling units such as radiator, stove and spots which get
direct sun lights would not be suitable. Room Thermostat needs to be
located above the floor 150 cm height. Few trials may be made to find
the most convenient spot.
BATTERY PLACEMENT
Before starting, power off the device connected to the Room
Thermostat and make sure that the energy is cut off.
GENERAL SPECIFICATIONS
NORA 270S is a wired room thermostat. The user can adjust the room
temperature with the required temperature and get more comfortable
and economic heating/cooling.
Different Mode Options (Comfort Mode and Economy Mode)
Precise Temperature Measurement ON/OFF Control
Heating Calibration Wired Connection
Heating/Cooling Modes TPI Algorithm
NORA 270S AND EQUIPMENTS
TECHNICAL DATA
ROOM THERMOSTAT
Buttons Functions
Economy Mode
Temperature Adjustment (Increasing)
Comfort Mode
Heating/Cooling Modes
Temperature Adjustment (Decreasing)
ON/OFF and Setting Button
1
2
3
4
5
6
1
2
3
4
5
6
As shown in the picture, press the screwdriver forward from the space
shown, bend the tabs and separate the front cover. Insert 2 new AAA
alkaline batteries in the battery housing with the correct battery
direction. Replace both batteries at the same time. Then align the
front part of your Room Thermostat to the back and squeeze it
towards the back.
Low Battery Warning:
When the “ ” icon appears on the screen, it
means “low battery warning”. It is recommended to replace the
batteries when this warning appears.
Warning:
When the product is not used for a long period (more than 15
days), remove the batteries. Otherwise, malfunctions that may occur
would be out of warranty.
Please throw your dead batteries into the waste bin for batteries.
ROOM THERMOSTAT WIRING DIAGRAM
Warning!
Operations within the heating / cooling unit or the electrical
installation must be carried out by professionally qualified persons.
ROOM THERMOSTAT TEMPERATURE CALIBRATION
Temperature sensors which are used in Room Thermostats are highly
sensitive. You may need to calibrate your Room Thermostat if you
would like to get the same temperature values with other
thermometers in your living space.
While your device is turned off, press and hold the "On/Off"button
for 3 seconds.
Press the "On/Off" button until the “ ” menu appers. In order to
see the desired temperature, set the temperature difference by
press the “Temperature Adjustment Buttons”. This value can be
o
o
arranged between “-8 C" and “+8 C".
To save the settings and exit, press the "On/Off" button until the
device turns off.
o
Note:
Recommended tempreture calibration is “0.0 C”.
FACTORY SETTINGS RESET
You can reset your Room Thermostat to its default factory settings.
This operation resets the mode temperature values, calibration
setting and heating/coling modes to factory setting. To reset your
Room Thermostat to factory setting:
While your device is turned off, press and hold the "On/Off"button
for 3 seconds.
Press the “On/Off” button until “ ” menu appears.
While in the “ ” menu, select the “ ” option by using “+” or “-”
buttons and press the “On/Off” button.
Your device will be turned off and reset to factory settings.
MODE SETTINGS
There are 2 modes in the Room Thermostat. These are Comfort Mode
“ ” and Economy Mode “ ”. Modes work according to the pre-set
temperature values adjusted by user.
In order to change the comfort mode temperature value;
Press and hold the comfort mode button for 3 seconds.
Change the temperature value by pressing “+” or “-“ buttons.
Press the comfort mode button once to save the changes you have
made or wait 10 seconds.
Room Temperature
Set Temperature
Economy Mode
Comfort Mode
Heating Indicator
- If the Heating Indicator is blinking, the heating unit is
working.
- If the Heating Indicator is steady, the heating unit is not
working.
Cooling Indicator
- If the Cooling Indicator is blinking, the cooling unit is
working.
- If the Cooling Indicator is steady, the cooling unit is not
working.
Battery Indicator
1
2
3
4
5
6
7
1
2
3
NORA 270S Room Thermostat
85mm / 125mm / 19.2mm
3V DC (2 x AAA alkaline battery)
2A/30VDC (Resistive load)
0.5A/125VAC (Resistive load)
o
0.1 C
o
o
(5 C) – (30 C)
1 Year (2 x AAA)
o
o
(-10 C) – (+50 C)
o
o
(-20 C) – (+60 C)
Dimensions
Operating Current
Relay NO Switching Current
Temperature Measurement
Accuracy
Operating Temperature Range
Battery Life
Operating Temperature
Storage Temperature
NORA 270S
USER MANUAL
Alkaline Battery
1
2
3
4
5
6
7
A
A
A
A
A
A
Dowels and
Screws
generallife.com.tr
COM
NO
HEATING/COOLING UNIT
NORA 270S
USER MANUAL
generallife.com.tr
DIGITAL ROOM THERMOSTAT
ENGLISH
DIGITAL ROOM THERMOSTAT