2. Install Cartridge. Thread Cartridge (Fig.2)
into top half of Pressure Vessel (Be
careful not to cross thread) until contact
is first made with dark blue Cartridge
Gasket.
Then tighten
4
turn only. Do
not overtighten. Be sure Pressure Vessel
Flanges and Housing Gasket are clean and
free of dents, nicks or cuts.
3. Reassemble Pressure Vessel. Place
Gasket on Flange of lower half of Pressure
Vessel (Fig.3) and reassemble V-Clamp,
keeping Seagull
IV
logo upright. The Wing
Nut on the Clamp should be tightened
snugly, by hand only.
Use no tools to
tighten. You may apply a light coating
of petroleum jelly to the housing gasket
to assure ease of opening and closing of
the system.
General Installation Instructions
Please retain for future servicing of your SEAGULL
®
IV Water Purifier
4. Install Faucet. The X-1F is furnished
with General Ecology’s exclusive “Top
Mount” Ceramic Disc Faucet. If a suitable
hole isn’t available, prepare a
¾
” hole to
install your faucet. Cut out Mounting
Pattern supplied on page number 8 and
use for rough positioning. Tape pattern
in place, then for final positioning, place
Faucet on pattern on top of sink and
check for correct position of faucet body,
spout and lever. Make sure of clearance
above and below sink before drilling
mounting hole. Porcelain sinks require
special care. For best results we suggest
you contact your dealer or others with
experience in making cutout in porcelain
sinks. We have had good success with
the following procedure. First cover the
area being penetrated with masking
or duct tape and, from beneath, drill a
d
” pilot hole upward, a
¼
” hole and
then a
g
” hole and finally the
¾
” hole
necessary to mount the faucet. For
man-made and stone products consult
counter-top manufacturer’s guidelines.
For stainless steel sinks use a “Greenlee”
type punch/die tool. If you do not have
a “Greenlee” punch and are installing on
stainless, follow the same procedure as
on porcelain/cast iron sinks. Be sure sink
ledge at drill hole is “flat” and burr free.
Dark Blue
Housing
Gasket
Flange
Figure
3
Cartridge
Figure
2
Figure
1
1. Open Canister. Remove V-Clamp and
separate Pressure Vessel upper and
lower halves.
1a. Remove Cover. Remove small plastic
protective cover from your new cartridge
by pulling the tab end up (Fig.1a).
V-Clamp
1a
Preliminary:
If needed, purchase from local hardware store and install Connector T (available from General Ecology) or
Saddle Valve with a
a
” compression outlet in cold water supply line.
Figure
4
5. Connect Hose directly to Faucet Stem
and tighten securely by hand.
Do not
overtighten. Insert and thread Spout
into base,
Do not over tighten (Fig.
4)
. Drop free end of Connector Hose
through previously prepared hole and
position Faucet in hole.
Install Top Mount Faucet - SEAGULL IV X-1F System
General Ecology, Inc. — 4
It is important to note control handle position
and “pull direction” to insure adequate
clearance.
Also note the “swing feature” of the faucet’s
spout that allows many different mounting
options.
Make sure of all clearances
above and below
sink before drilling mounting hole.
QUESTIONS?
Call 1-800-441-8166
for Customer service
To change “pull direction” of handle
To change “pull direction” of handle on faucet,
lift handle off stem and reposition stainless
steel pin to alternate location. Reinstall
handle.
Stainless
steel pin
Place Pin on right
or left side