Electrical Requirements
6
Supply
This appliance should be connected to the mains supply via a suitable
switched socket in an accessible position.
Changing the
Plug
Rewirable Plug
Moulded Plug
The flexible mains lead is supplied connected to a BS1363 fused plug with
a 13 amp capacity.
The wires in the mains lead are in accordance with the following:
GREEN/YELLOW
– EARTH
BLUE
– NEUTRAL
BROWN
– LIVE
If the plug is changed, the coloured wires in the mains lead may not
correspond with the colours of the markings identifying the terminals in
the plug. Therefore wire is as shown above. Should the mains lead ever
require replacement, this operation must be carried out by a competent
person. Only use specially prepared 3 core recommended spares cable.
The correct replacement of the fuse is identified by the colour coding in
the base of the plug or the colour that is embossed in words in the base of
the fuse recess, or elsewhere on the plug. Only 13 amp replacement fuses
which are ASTA approved to BS1362 should be fitted. After replacement
of a fuse in the plug, the fuse cover must be refitted. Fuse covers may be
obtained from your local Regional Electricity Company.
WARNING: This appliance must be earthed. Refer to Rating
plate for Voltage supply.
WARNING: The plug must not be used without a fuse cover.
NOTE: Replacement mains cables must only be obtained from our recommended
Spares stockist.
NOTE: IF IN DOUBT CONSULT A QUALIFIED ELECTRICIAN.
13
AMP
FUSE
BROWN
TO
LIVE
CORD
CLAMP
BLUE
TO
NEUTRAL
GREEN & YELLOW
TO EARTH