General Components WOLF6000AW Quick Start Manual Download Page 2

6.  SETTING WATER HEAT MODE 

 

 

 

 

 

 

 

 

 

 

7.  START AND STOP HEATER 

 

 

 

 

 

 

 

8.  SETTING SCHEDULED OPERATION 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9.  SETTINGS 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Using 

[<] 

and 

[>]

 keys, navigate 

to water tank icon and press 

[Enter]

In the following menu select one 
of the following modes: 

GAS 

        LPG or Diesel only 

MIX 1

  

electrical 900 W+GAS 

MIX 2

  

electrical 1800 W+GAS 

EL 1

  

electrical only, 900 W 

EL 2

  

electrical only, 1800 W 

Using 

[<]

 and 

[>]

 keys, navigate 

to 

Stopwatch Icon

 and press 

[Enter]

 

Note: for best heating performance, always set MIX2.  

Note: MIX1, MIX2, EL1 and EL2 only work when RV is 
connected to 120V/240V service. 

.

 

In the following screen, using 

[<]

 

and 

[>]

 and 

[Enter]

 keys, enter the 

desired 

Start Time

.

 

The program is now set

 

To shutdown the heater at any 

moment, press and hold [Enter] 

button for more than 3 seconds.

 

Press and hold [Enter] button for 3 seconds to start the 

heater back up again.

 

Note: it may take up to two minutes for the heater to 
cool off and stop completely. 

.

 

In the following screen, using 

[<]

 

and 

[>]

 and 

[Enter] 

keys, enter the 

desired 

End Time

.

 

In the following screen, using 

[<]

 

and 

[>]

 and 

[Enter]

 keys, enter the 

desired 

Room Temperature

.

 

In the following screen, using 

[<]

 

and 

[>]

 and 

[Enter]

 keys, enter the 

desired 

Water Temperature

.

 

In the following screen, using 

[<]

 

and 

[>]

 and 

[Enter]

 keys, enter the 

desired 

Water Heat Mode

.

 

In the following screen, using 

[<]

 

and 

[>]

 and 

[Enter]

 keys, enter the 

desired 

Fan Speed

.

 

In the following screen, using 

[<]

 and 

[>]

 and 

[Enter]

 

keys, enable (or disable) the program.

 

While in main menu, using 

[<] 

and 

[>]

 keys, navigate to 

Wrench Icon

 and press 

[Enter]

.

 

 

In the following screen, using 

[<]

 

and 

[>]

 and 

[Enter]

 keys, enter the 

desired 

Offset

 

Offset allows you to calibrate the remote temperature 

sensor reading to ±5 degrees of its actual value.

 

In the following screen, using 

[<]

 

and 

[>]

 and 

[Enter]

 keys, enter the 

desired 

Time Format

  

(12H or Military)

 

In the following screen, using 

[<]

 

and 

[>]

 and 

[Enter]

 keys, enter the 

desired 

LCD Brightness

  

Between 0 and 10

 

Index screen allows you to check 

software version of the timer and 

heater controller. 

 

FUEL

 option of the menu allows 

you to prime the fuel line after the 

installation or after you ran out of 

fuel. 

 

You can set the priming duration 

of up to 90 seconds. Press return 

at any time to stop priming. 

Reviews: