7. SETTING SCHEDULED OPERATION
8. FUEL LINE PRIMING
This function enables fuel pump for a
short period of time to help get rid of air inside the
fuel lines after initial installation or if the fuel tank
ran out of fuel.
It is recommended to disconnect the fuel
line from the heater before using this function to
avoid flooding of the heater.
Refrain from using this function and refer
to the nearest dealer or experienced mechanic for
help if you don’t feel confident doing this.
Depending on length of your fuel line, you
may need to run priming cycle several times to
fully prime the line.
9. READING AND CLEARING ERRORS
10. FACTORY RESET
Following steps reset timer settings only. This
operation does not affect heater’s ECU.
Using
[<]
and
[>]
keys, navigate
to
Program Icon
and press
Ok
.
Program Number
segment lights up.
Select program number using
[<]
and
[>]
keys and press
Ok
.
Program Status
screen comes up.
Select
On
to enable or
Off
to disable
the program and press
Ok
.
Program Duration
screen comes up.
Select cycle duration between 50
and 800 minutes
and press
Ok
.
Program Start
screen comes up.
Select start time hour (military, 0-23
hours)
and press
Ok
.
Select start time minutes
and
press
Ok
.
Day of Week
screen comes up.
Scroll through every day of the week
and select On or Off as needed.
The program is now set
.
To set programs 2 and 3 repeat
the process, changing the
program number in step 3.
Using
[<]
and
[>]
keys, navigate
to
Clock Icon
and press
[<]
and
[>]
keys simultaneously.
Using
[<]
and
[>]
keys, navigate
to
Clock Icon
.
Digital timer allows you to read
and clear six most recent faults
stored in heater’s ECU.
To display
Error Screen
while in
heat mode, press
[<]
and
[>]
keys simultaneously.
Use
[<]
and
[>]
keys to scroll
through error codes 1E – 6E.
To clear all errors, press
[<]
and
[>]
simultaneously.
To go back to previous screen,
press
Power
or
Ok
button.
If the fault keeps coming up
after you reset it, please refer to
the nearest dealer to rectify the
cause of the problem.
P1 should appear on the screen.
Using
[<]
or
[>]
key, change P1
to P2 and press
Ok
.
Fuel pump starts pumping.
Pump will prime at frequency of
2.5Hz and stop after 90 seconds.
During this period, fuel pump
should deliver 15.5 ml of fuel.
Use any key to stop the pump
and exit
Priming Mode
.
Press
[<]
and
[>]
keys
simultaneously.
Using
[<]
or
[>]
key, select
01
and press
Ok
.
Timer is now reset to factory
settings.