Owner’s Manual for Portable Generator
15
Inspect Engine Oil Level
Inspect engine oil level prior to each use, or
every 8 hours of operation.
1. Place generator on a level surface.
2. Clean area around oil fill.
3. See
. Remove oil fill cap and
wipe dipstick clean.
Figure 4-1. Engine Oil Fill
4. Screw dipstick into filler neck. Verify oil
level is within safe operating range. See
.
Figure 4-2. Safe Operating Range
5. Add recommended engine oil as neces-
sary.
6. Replace oil fill cap and hand-tighten.
NOTE:
Some units have more than one oil fill
location. It is only necessary to use one oil fill
point.
Change Engine Oil
When using generator under extreme, dirty,
dusty conditions, or in extremely hot weather,
change oil more frequently.
NOTE:
Don’t pollute. Conserve resources.
Return used oil to collection centers.
Change oil while engine is still warm from run-
ning, as follows:
1. Place generator on a level surface.
2. Clean area around oil fill, and oil drain
plug.
3. Remove oil fill cap.
4. Remove oil drain plug and drain oil com-
pletely into a suitable container.
5. Install oil drain plug and tighten securely.
6. Slowly pour oil into oil fill opening until oil
level is between the crosshatch marks on
dipstick. DO NOT overfill.
7. Install oil fill cap, and finger tighten.
8. Wipe up any spilled oil.
9. Properly dispose of oil in accordance with
all applicable regulations.
Air Filter
Engine will not run properly and may be dam-
aged if run with a dirty air filter. Service air fil-
ter more frequently in dirty or dusty conditions.
To service air filter:
1. See
. Turn knob (A) and remove
air filter cover.
2. Wash in soapy water. Squeeze filter dry in
clean cloth (DO NOT TWIST).
3. Clean air filter cover before re-installing it.
NOTE:
To order a new air filter, contact the
nearest Authorized Service Dealer at 1-888-
GENERAC (1-888-436-3722).
(000135)
CAUTION
Engine damage. Verify proper type and quantity of
engine oil prior to starting engine. Failure to do so
could result in engine damage.
-4 °F
(-20 °C)
14 °F
(-10 °C)
32 °F
(0 °C)
50 °F
(10 °C)
68 °F
(20 °C)
86 °F
(30 °C)
104 °F
(40 °C)
SAE 15W-40
SAE 20W
SAE 30
SAE 40
SAE 10-W30
SAE 20W
SAE 10W
000578
(000139)
WARNING
Risk of burns. Allow engine to cool before
draining oil or coolant. Failure to do so could
result in death or serious injury.
000115
000116
(000130)
WARNING
Accidental Start-up. Disconnect the negative battery
cable, then the positive battery cable when working
on unit. Failure to do so could result in death
or serious injury.
Summary of Contents for XD5000E
Page 21: ...Owner s Manual for Portable Generator 19 Notes ...
Page 22: ...20 Owner s Manual for Portable Generator ...
Page 23: ......
Page 46: ...Manual del propietario del generador portátil 20 Notas ...
Page 47: ...Manual del propietario para generador portátil 21 Notas ...
Page 48: ...Manual del propietario para generador portátil 22 Notas ...
Page 49: ......
Page 72: ...Manuel de l utilisateur de la génératrice portable 20 Remarques ...
Page 73: ...Manuel de l utilisateur de la génératrice portable 21 Remarques ...
Page 74: ...22 Manuel de l utilisateur de la génératrice portable Remarques ...
Page 75: ......