Tank Options

™

MDEQ

OPT

™

Florida DERM/DEP

OPT

™

Chicago Fire Code

OPT

™

IFC Certification

CALL

™

ULC

CALL

Other Custom Options Available from your Generac Industrial Power Dealer

* All measurements are approximate and for estimation purposes only. Weights and dBA are available on install drawings and sound data sheets, respectively. 

YOUR FACTORY RECOGNIZED GENERAC INDUSTRIAL DEALER

OPEN SET

RUN TIME HOURS

USABLE CAPACITY (GAL)

NO TANK

-

8

334

24

1001

24

1001

48

2002

STANDARD ENCLOSURE

RUN TIME HOURS

USABLE CAPACITY (GAL)

NO TANK

-

8

334

24

1001

24

1001

48

2002

LEVEL 1 SOUND ENCLOSURE

RUN TIME HOURS

USABLE CAPACITY (GAL)

NO TANK

-

8

334

24

1001

24

1001

48

2002

LEVEL 2 SOUND ENCLOSURE

RUN TIME HOURS

USABLE CAPACITY (GAL)

NO TANK

-

8

334

24

1001

24

1001

48

2002

5 of 4

SD600 

enclosure and tank configurations

Generac Power Systems, Inc. • S45 W29290 HWY. 59,  Waukesha, WI 53189 • generac.com

©2012 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin 0197220SBY-A / Printed in U.S.A. 09/27/12

Specification characteristics may change without notice. Dimensions and weights are for preliminary purposes only. Please consult a Generac Power Systems Industrial Dealer for detailed installation drawings.

Summary of Contents for SD600

Page 1: ... COMPLIANT 4 MEETS EPA STANDARDS INDUSTRIAL TESTED GENERAC APPROVED 4 ENSURES INDUSTRIAL STANDARDS POWER MATCHED OUTPUT 4 ENGINEERED FOR PERFORMANCE INDUSTRIAL GRADE 4 IMPROVES LONGEVITY AND RELIABILITY Alternator TWO THIRDS PITCH 4 ELIMINATES HARMFUL 3RD HARMONIC LAYER WOUND ROTOR STATOR 4 IMPROVES COOLING CLASS H MATERIALS 4 HEAT TOLERANT DESIGN DIGITAL 3 PHASE VOLTAGE CONTROL 4 FAST AND ACCURAT...

Page 2: ...pe Full Flow Cartridge System Voltage 24VDC Crankcase Capacity L Gal 60 15 8 Battery Charging Alternator 70 Amps at 24V Battery Size at 0ºC 1155 CCA Battery Group 8D Battery Voltage 2 12VDC Ground Polarity Negative ALTERNATOR SPECIFICATIONS Standard Model WEG Voltage Regulator Type Digital Poles 4 Number of Sensed Phases All Field Type Revolving Regulation Accuracy Steady State 1 Insulation Class ...

Page 3: ...3 571 857 1143 1429 1714 2000 Upsize 2 Upsize 2 Fuel Consumption Rates STANDBY Fuel Pump Lift m ft Percent Load gph lph 3 7 12 25 18 4 69 7 50 28 2 88 7 75 35 6 134 8 100 41 4 156 7 Refer to Emissions Data Sheet for maximum fuel flow for EPA and SCAQMD permitting purposes STANDBY Coolant Flow per Minute gpm lpm 114 1 432 Heat Rejection to Coolant BTU hr 1 589 760 Inlet Air cfm m3 min 30 088 852 Ma...

Page 4: ...r Opt Remote Relay Panel 8 or 16 Opt 7 Day Programmable Exerciser Std Special Applications Programmable PLC Std RS 232 Std RS 485 Std All Phase Sensing DVR Std Full System Status Std Utility Monitoring Req H Transfer Switch Std 2 Wire Start Compatible Std Power Output kW Std Power Factor Std Reactive Power Std All phase AC Voltage Std All phase Currents Std Oil Pressure Std Coolant Temperature Std...

Page 5: ... TANK 8 334 24 1001 24 1001 48 2002 LEVEL 1 SOUND ENCLOSURE RUN TIME HOURS USABLE CAPACITY GAL NO TANK 8 334 24 1001 24 1001 48 2002 LEVEL 2 SOUND ENCLOSURE RUN TIME HOURS USABLE CAPACITY GAL NO TANK 8 334 24 1001 24 1001 48 2002 5 of 4 SD600 enclosure and tank configurations Generac Power Systems Inc S45 W29290 HWY 59 Waukesha WI 53189 generac com 2012 Generac Power Systems Inc All rights reserve...

Reviews: