If a generator is being installed at this time, proceed 
to step 19. If a generator will not be installed at this 
time, perform steps 14 through 17 to complete the 
pre-wiring project.

14.   Open the outdoor connection box and unplug the 4-pin 

and 2-pin connector. Remove the black, white, red, 
and green wires that lead from the five foot pre-wired 
conduit. Make sure the mating wires from the 30 foot 
conduit are on the connection box terminal lugs (or 
ground screw), re-install all washers and nuts and 
secure them in place.

15.  Remove the lock nut holding the five foot pre-wired 

conduit coupling to the outdoor connection box. Slip 
the lock nut over the wires and plug, then remove 
the conduit from the connection box. Use a knockout 
plug to close off the opening where the conduit was 
removed.

  The external connection box must be locked to 

ensure safety and to discourage tampering.

16.  For pre-existing buildings, switch the service main 

circuit breaker back on to provide utility power to the 
building.

17.  Save the five foot pre-wired conduit for re-installation 

at time of generator installation. At that time, re-install 
the conduit by reversing steps 14 and 15. The ground-
ing strap will also be installed with the generator. Save 
this guide for reference at time of generator installa-
tion.

DANGER

  Be sure the service main circuit breaker is switched 

OFF at time of generator installation.

This completes the pre-wiring portion of the 100 Amp 
Automatic Transfer Switch/Load Center Installation. 
Proceed with step 18 for generator installation.

18.  Place the generator and mounting pad in the location 

prepared in steps one through five.

19.  Attach one end of the grounding strap (No. 12 AWG 

stranded copper wire) to grounding rod, and the other 
end to the grounding lug (located at rear corner of 
unit). Make sure the grounding rod and strap are not 
exposed above ground level (NEC code applies to 
grounding method).

NOTE:

The generator mode switch should be placed in the OFF 
position. Generator main line circuit breaker should be 
switched to the OFF or OPEN position.

20.  Access wiring connections for installation of five foot 

harness at the generator. To gain access to wiring con-

nections and the circuit breaker you must remove the 

cover plate (black) over the control module. Remove 

the two screws retaining the cover plate. Lift the cover 

plate up and towards the front of the generator to 

remove.

Connect Five Foot Conduit to Generator

20

THE AUTOMATIC TRANSFER SWITCH/LOAD CENTER IS NOW INSTALLED!

Residential Transfer Switch Installation Guide

18

19

Summary of Contents for RTSF100A1

Page 1: ...4 16 and 17kW Generators This Automatic Transfer Switch with built in Load Center includes an Express Install Kit Saves on installation time and cost in many cases up to 50 compared to traditional tra...

Page 2: ......

Page 3: ...INSTRUCTIONS The manufacturer suggests that these rules for safe operation be copied and posted near the unit s installation site Safety should be stressed to all operators and potential operators of...

Page 4: ...th will be deter mined by the materials to be drilled and cut open end wrenches or adjustable wrenches socket wrenches or nut drivers standard and Phillips screwdrivers sledge hammer level pencil chan...

Page 5: ...mounting pad 49 L x 25 W 3 Lay black poly film to cover the area 4 Fill the area to ground level with pea gravel or crushed stone 5 Drive an eight foot grounding rod into the ground to grade Make sure...

Page 6: ...in emer gency load center in close proximity to the main distribution panel The transfer switch can be located to the left or right of the main distribution panel Two 2 feet is the suggested distance...

Page 7: ...nuts are included in installation kit Trace each black hot wire connected and wire nut the white neutral wire from the same Romex cable circuit to the matching circuit number on the white neutral wire...

Page 8: ...g strap will also be installed with the generator Save this guide for reference at time of generator installa tion DANGER Be sure the service main circuit breaker is switched OFF at time of generator...

Page 9: ...ing the supplied threaded flexible fuel line Use a pipe sealant suitable for gaseous fuel connections Check connections for leaks by opening manual fuel shut off valve and swab or spray con nections w...

Page 10: ...8 Residential Transfer Switch Installation Guide Installation Drawing 0H0258 A...

Page 11: ...9 Residential Transfer Switch Installation Guide Installation Drawing 0H0258 A...

Page 12: ...Residential Transfer Switch Installation Guide Installation Drawing 0G8573 A 10 10...

Page 13: ...11 Residential Transfer Switch Installation Guide Electrical Schematic Drawing 0G7959 A...

Page 14: ...12 Residential Transfer Switch Installation Guide Wiring Diagram Drawing 0G7958 A...

Page 15: ...13 Residential Transfer Switch Installation Guide Wiring Diagram Drawing 0G7958 A...

Page 16: ...14 Residential Transfer Switch Installation Guide Load Center Exploded View Drawing 0G8786 D...

Page 17: ...1 HARN GTS MAIN PNL 8CIR W NEUT 0G8139 1 HARN GTS MAIN PNL 10CIR W NEUT 0G8140 1 HARN GTS MAIN PNL 12CIR W NEUT 0G7955 1 HARN GTS MAIN PNL 14CIR W NEUT 0G8141 1 HARN GTS MAIN PNL 16CIR W NEUT ITEM PAR...

Page 18: ...16 Residential Transfer Switch Installation Guide Notes...

Page 19: ...17 Residential Transfer Switch Installation Guide Notes...

Page 20: ...Part No 0G8571 Revision E 08 10 09 Catalog No KGATX100 1SI Printed in U S A...

Reviews: