Application & Engineering Data

Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage.  No overload capability is available for this rating.  (All ratings in accordance with BS5514, 
ISO3046 and DIN6271).  (All ratings in accordance with BS5514, ISO3046, ISO8528, SAE J1349 and DIN6271).

QT130

GENERATOR SPECIFICATIONS

TYPE

Synchronous

ROTOR INSULATION

Class F or H (see Data Label)

STATOR INSULATION

Class H

TELEPHONE INTERFERENCE FACTOR (TIF)

<50

ALTERNATOR OUTPUT LEADS 3-PHASE/1-PHASE

6/4 wire

BEARINGS

Sealed Ball

COUPLING

Gear Drive

LOAD CAPACITY (STANDBY RATING)

130 kW

EXCITATION SYSTEM

Brushless

VOLTAGE REGULATION

TYPE

Full Digital

SENSING

Three Phase

REGULATION

± 1%

GENERATOR FEATURES

Revolving field heavy duty generator
Directly connected to the engine
Operating temperature rise 120 °C above a 40 °C ambient
Insulation is Class F rated at 130 °C rise
All models are fully prototyped tested

ENCLOSURE FEATURES

A

luminum all weather 

protective enclosure 

options available

Ensures protection against mother nature. 

 

Electrostatically applied textured epoxy paint for 

added durability.

Enclosed critical grade 

muffler

Quiet, critical grade muffler is mounted inside 

the unit to prevent injuries.

Small, compact, 

attractive

Makes for an easy, eye appealing installation.

SAE

Sound attenuated enclosure ensures quiet 
operation.

ENGINE SPECIFICATIONS

MAKE

Generac

MODEL

V-type

CYLINDERS

10

DISPLACEMENT

6.8 Liter

BORE

3.55

STROKE

4.17

COMPRESSION RATIO

9:1

INTAKE AIR SYSTEM

Naturally Aspirated

VALVE SEATS

Hardened

LIFTER TYPE

Hydraulic

GOVERNOR SPECIFICATIONS

TYPE

Electronic

FREQUENCY REGULATION

Isochronous

STEADY STATE REGULATION

± 0.25%

ENGINE LUBRICATION SYSTEM

OIL PUMP

Gear

OIL FILTER

Full flow spin-on cartridge

CRANKCASE CAPACITY

5 Quarts

ENGINE COOLING SYSTEM

TYPE

Closed

WATER PUMP

Belt driven

FAN SPEED

1950

FAN DIAMETER

26 inches

FAN MODE

Puller

FUEL SYSTEM

FUEL TYPE

Natural gas, propane vapor

CARBURETOR

Down Draft

SECONDARY FUEL REGULATOR

Standard

FUEL SHUT OFF SOLENOID

Standard

OPERATING FUEL PRESSURE

11” - 14” H2O

ELECTRICAL SYSTEM

BATTERY CHARGE ALTERNATOR

12V 30 Amp

SMART BATTERY CHARGER

12V, 2 Amp

RECOMMENDED BATTERY

Group 24F, 12V, 525CCA

SYSTEM VOLTAGE

12 Volts

Summary of Contents for QT130

Page 1: ... the surge loads to the engine An unequalled 1 voltage regulation SINGLE SOURCE SERVICE RESPONSE from Generac s extensive dealer network provides parts and service know how for the entire unit from the engine to the smallest electronic component GENERAC TRANSFER SWITCHES Long life and reliability are synonymous with GENERAC POWER SYSTEMS One reason for this confidence is that the GENERAC product l...

Page 2: ...available Ensures protection against mother nature Electrostatically applied textured epoxy paint for added durability Enclosed critical grade muffler Quiet critical grade muffler is mounted inside the unit to prevent injuries Small compact attractive Makes for an easy eye appealing installation SAE Sound attenuated enclosure ensures quiet operation ENGINE SPECIFICATIONS MAKE Generac MODEL V type ...

Page 3: ...x ambient temperature C F 6 450 4 5 496 000 60 150 50 140 COMBUSTION AIR REQUIREMENTS Flow at rated power 60 Hz cfm 336 SOUND EMISSIONS IN DBA Exercising at 7 meters Normal operation at 7 meters 65 75 EXHAUST Exhaust flow at rated output 60 Hz cfm Exhaust temp at muffler outlet ºC F 1 119 521 970 ENGINE PARAMETERS Rated synchronous RPM 60 Hz 2970 POWER ADJUSTMENT FOR AMBIENT CONDITIONS Temperature...

Page 4: ...Automatic Voltage Regulation with Over and Under Voltage Protection Standard Automatic Low Oil Pressure Shutdown Standard Overspeed Shutdown Standard 72Hz High Temperature Shutdown Standard Overcrank Protection Standard Safety Fused Standard Failure to Transfer Protection Standard Low Battery Protection Standard 50 Event Run Log Standard Future Set Capable Exerciser Standard Incorrect Wiring Prote...

Page 5: ...c Power Systems Inc S45 W29290 HWY 59 Waukesha WI 53189 generac com 2011 Generac Power Systems Inc All rights reserved All specifications are subject to change without notice Bulletin 0188700SBY C Printed in U S A 02 18 11 QT130 ...

Reviews: