TROUBLESHOOTING GUIDE
PROBLEM CAUSE
CORRECTION
Engine won’t crank.
1. 15 amp fuse blown.
1. Replace fuse.
2. Loose or corroded or defective
2. Tighten, clean or replace
battery cables.
battery cables as necessary.
3. Defective starter contactor.
3. Replace contactor.*
4. Defective starter motor.
4. Replace starter motor.*
5. Dead or Defective Battery.
5. Remove, change or replace battery.
6. 5 amp fuse blown.
6. Replace fuse.*
Engine cranks but won't start
1. Out of fuel.
1. Replenish fuel.
2. Fuel solenoid (FS) is defective
2. Replace solenoid.*
3. Open Wire #14A from Engine Control
3. Reconnect wire.
circuit board.
4. Spark plugs defective.
4. Clean, regap or replace plugs.
5. Door on tank not closed.
5. Close door on tank.
Engine starts hard, runs rough.
1. Flame arrestor (air cleaner) plugged or
1. Clean or replace as needed.
damaged.
2. Plugged fuel line.
2. Unclog fuel line.
3. Defective spark plugs.
3. Clean, regap or replace plugs.
4. Fuel pressure incorrect.
4. Confirm fuel pressure to regulator is as
recommended in SPECIFICATIONS.
Engine starts then shuts down.
1. Engine oil level is low.
1. Check oil and add oil as needed.
2. Engine is overheated.
2. Check cooling system for leaks.
3. Defective Low Oil Pressure Switch
3. Replace switch.*
4. Defective Coolant Temperature Switch
4. Replace switch.*
5. Defective Control Module circuit board.
5. Replace board.*
6. Coolant Level is Low.
6. Repair leak - Add coolant.
7. Defective Low Coolant Level Switch
7. Replace Switch.*
AUTO/OFF/MANUAL Switch at OFF, 1. Defective AUTO/OFF/MANUAL switch
1. Replace switch.*
engine continues to run
2. Open/disconnected wire #15A between
2. Reconnect/close wire.
AUTO/OFF/MANUAL switch and Control
Module circuit board.
3. Defective Control Module circuit board
3. Replace board.*
No AC output from generator.
1. Check main line circuit breaker.
1. Reset to ON or CLOSED.
2. Check circuit breaker & fuses.
2. Reset and replace, if necessary.
3. Transfer switch set to NORMAL position
3. Set to GENERATOR position.
4. Generator internal failure.
4. *
5. Thermal circuit breaker open.
5. Auto-reset - Wait 5 min. and attempt restart.
*Contact the nearest Authorized Dealer for assistance.
12-1
Trblsht001 R
ev.
B 06/10
Troubleshooting
Summary of Contents for QT100
Page 27: ...Notes ...
Page 28: ......
Page 30: ......
Page 32: ......
Page 34: ......
Page 36: ......
Page 38: ......
Page 40: ......
Page 42: ......
Page 44: ......
Page 46: ......
Page 48: ......
Page 50: ......
Page 52: ......
Page 54: ......
Page 56: ......
Page 58: ......
Page 60: ......
Page 62: ......
Page 64: ......
Page 65: ......
Page 66: ......
Page 67: ......
Page 68: ......
Page 69: ......
Page 70: ......
Page 71: ......
Page 72: ......
Page 73: ......
Page 74: ......
Page 75: ......
Page 76: ......
Page 77: ......
Page 78: ...Notes ...
Page 79: ...Notes ...