Generac Power Systems PWRell 0009890 Owner'S Manual Download Page 12

8

Owner’s Manual for Genera PWRcell Battery

General Information

About Generac PWRcell Battery

The Generac PWRcell Battery is the storage component 
of the Generac PWRcell system. The Generac PWRcell 
Battery  can  be  used  for  grid-connected  solar 
applications, such as self-supply, rate arbitrage and clean 
backup  power.  The  Generac  PWRcell  Battery  is 
designed  to  work  seamlessly  with  Generac  PV  Link 
Optimizers and the Generac PWRcell Inverter to form the 
Generac PWRcell system for grid-tie solar-plus-storage. 
All Generac PWRcell products use the REbus™ 380VDC 
nanogrid to connect energy sources, storage and loads. 

The  REbus  nanogrid  automates  the  flow  of  power  to 
enable  plug-and-play  setup  and  operation  of  Generac 
PWRcell equipment. 
In 

Figure 2-4

,  a  REbus  compatible  Generac  PWRcell 

Inverter  (E)  is  directly  connected  to  Generac  PV  Link 
Optimizers (B) and Generac PWRcell Battery (E) on the 
DC (REbus) line (D). To the right of the inverter are AC 
lines:  240VAC  or  208VAC  for  grid  and  home  loads  (G), 
and protected load (H) support up to 50A.

009893

A

B

C

D

E

F

G

H

.

Figure 2-4. Generac PWRcell System Example

A

Solar Panels

E

Generac PWRcell Inverter

B

Generac PV Link Optimizers

F

Grid 

C

Generac PWRcell Battery

G

Loads

D

REbus

H

Protected Loads

.

Communication

All  communication  between  REbus  devices  takes  place 
over  the  REbus  conductors  using  Power  Line  Carrier 
(PLC)  communication.  No  additional  communication 
wiring  or  equipment  is  required  for  communication 
between a Generac PWRcell Battery, inverter, PV array, 
and/or other REbus enabled batteries.

System Operational Modes

The  Generac  PWRcell  system  has  several  operational 
modes  available  for  various  installation  configurations, 
markets,  and  applications.  Operational  modes  are
selected  through  the  Generac  PWRcell  Inverter  control 
panel.  The  inverter  prioritizes  the  distribution  of  power 
differently based on the selected operational mode.
See  the  Generac  PWRcell  Inverter  installation  and 
operation  manuals  for  complete  instructions  on 
configuring the entire system for each operational mode.

Inverter Control Panel

See 

Figure 2-5

.  The  Generac  PWRcell  Battery  is 

controlled through the Generac PWRcell Inverter control 
panel. Use the inverter control panel to enable or disable 
the  battery,  and  to  set  the  operational  mode  for  the 
Generac  PWRcell  system.  See  the  Generac  PWRcell 
Inverter Owner’s Manual for more information on settings 
and display screens.

REbus

Inverter

Internet

Shutdown

(hold)

0009894

Figure 2-5. Inverter Control Panel

Summary of Contents for PWRell 0009890

Page 1: ...Loss of life This product is not intended to be used in a critical life support application Failure to adhere to this warning could result in death or serious injury Register your Generac product at...

Page 2: ...ion is performed promptly and to have the equipment checked periodically by an ASD Normal maintenance service and replacement of parts are the responsibility of the owner operator and as such are not...

Page 3: ...rial Number Locations 6 Unit Dimensions 6 Component Locations 7 Battery Disconnect Switch 7 Battery Status LED 7 About Generac PWRcell Battery 8 Communication 8 System Operational Modes 8 Inverter Con...

Page 4: ...iv Owner s Manual for Generac PWRcell Battery This page intentionally left blank...

Page 5: ...m on how to correctly start operate and stop the unit in case of emergency Safety Rules The manufacturer cannot anticipate every possible cir cumstance that might involve a hazard The alerts in this m...

Page 6: ...d result in death serious injury and equipment or property damage IMPORTANT NOTE See individual unit specifications for required maintenance and run times pertaining to use Connecting Generac PWRcell...

Page 7: ...ould result in death or serious injury 000155a WARNING Electric shock Only a trained and licensed electrician should perform wiring and connections to unit Failure to follow proper installation requir...

Page 8: ...Shutdown press and hold Shutdown A Safety shutdown LED B will illuminate and LCD screen C will indicate Safety Shutdown has been initiated REbus Inverter Internet Shutdown hold 009656 A C B Figure 1 1...

Page 9: ...Ebus Communication Protocol REbus DC Nanogrid Voltage Input Output VDC 360 420 Round Trip Efficiency DC to DC 96 5 Temperature Operating Temperature Limits F C 41 113 5 45 Recommended Temperature Rang...

Page 10: ...ameplate Record the information from these tags so it is available if the tags are lost or damaged When ordering parts or requesting assistance you may be asked to provide this information A 0009891 F...

Page 11: ...battery monitoring system BMS electronics NOTE Battery Disconnect can be locked in the OFF position if required NOTE Turn Battery Disconnect OFF whenever system will be powered down and left inactive...

Page 12: ...enerac PV Link Optimizers F Grid C Generac PWRcell Battery G Loads D REbus H Protected Loads Communication All communication between REbus devices takes place over the REbus conductors using Power Lin...

Page 13: ...able for Self Supply and other non backup uses but lowers the islanding reserve in the event of an outage Raising this setpoint lowers capacity available for Self Supply and related modes but increase...

Page 14: ...rty damage While in Sleep Mode Generac PWRcell performs Power Searches at regular intervals During a Power Search Generac PWRcell wakes up energizes the REbus Nanogrid and scans for potential sources...

Page 15: ...PWRcell Inverter and charging from the Gen erac PWRcell PV Link and other sources Manual Enable See Figure 2 7 If LED B lights solid red when Battery Disconnect switch is turned ON the Generac PWRcel...

Page 16: ...12 Owner s Manual for Genera PWRcell Battery General Information This page intentionally left blank...

Page 17: ...ed air or water NOTE Allow filter to dry before reinstalling 5 Reinstall filter If air filter is damaged contact Generac Customer Service at 1 888 GENERAC 1 888 436 3722 or visit www gen erac com for...

Page 18: ...Dealer shall prepare a written decommissioning plan that provides the overview of the decommissioning process developed specifically for the Generac PWRCell Battery system that is to be decommissioned...

Page 19: ......

Page 20: ...ghts reserved Specifications are subject to change without notice No reproduction allowed in any form without prior written consent from Generac Power Systems Inc Generac Power Systems Inc S45 W29290...

Reviews: