![Generac Power Systems MC10000 Owner'S Manual Download Page 9](http://html1.mh-extra.com/html/generac-power-systems/mc10000/mc10000_owners-manual_2209604009.webp)
Generac Portable Products MC10000 Extended Life Generator
9
120 Volt AC, 30 Amp Locking
Receptacle
Use a NEMA L530 plug with this receptacle. Connect
a 3wire cord set rated for 125 Volts AC at 30 Amps to
the plug (Figure 6).
Use this receptacle to operate 120 Volt AC, 60 Hz,
single phase loads requiring up to 3600 watts (3.6 kW)
of power at 30 AC Amps. The outlet is protected by a
30 Amp pushtoreset circuit breaker.
120/240 Volt AC, 30 Amp Locking
Receptacle
Use a NEMA L1430 plug with this receptacle.
Connect a 4wire cord set rated for 250 Volts AC at
30 Amps (or greater) (Figure 7). You can use the same
4wire cord if you plan to run a 120 Volt load.
This receptacle powers 120/240 Volt AC, 60 Hz, single
phase loads requiring up to 3600 watts of power
(3.6 kW) at 30 AC Amps for 120 Volts; 7200 watts of
power (7.2 kW) at 30 AC Amps for 240 Volts. The
outlet is protected by a 30 Amp pushtoreset circuit
breaker.
Figure 6 120 Volt, 30 Amp, Locking Receptacle
Figure 7 120/240 Volt, 30 Amp, Locking Receptacle