Section 2 – Operation
Portable Generator System
2.1 KNOW THE GENERATOR
Read the Owner’s Manual and Safety Rules before operating this
generator.
Compare the generator to Figures 4 through 6 to become familiarized
with the locations of various controls and adjustments. Save this
manual for future reference.
Figure 4 - Control Panel
1. 12 Volt DC, 10 Amp Receptacle
– This receptacle allows the
capability to recharge a 12 volt DC storage battery with provided
battery charge cables.
2. 120 Volt AC, 20 Amp, Duplex Receptacle
– Supplies electrical
power for the operation of 120 Volt AC, 20 Amp, single-phase, 60
Hz electrical lighting, appliance, tool and motor loads.
3. 120 Volt AC, 20A Duplex GFCI Receptacle
– Supplies ground
fault protected electrical power for operation of 120 volt AC 20
amp, single-phase, 60 Hz electric lighting, appliances, tools and
motor loads.
4. 120 Volt AC, 30 Amp Locking Receptacle
– Supplies electrical
power for the operation of 120 Volt AC, 30 Amp, single-phase, 60
Hz electrical lighting, appliance, tool and motor loads.
5. 120/240 Volt AC, 30 Amp Locking Receptacle
– Supplies
electrical power for the operation of 120 and/or 240 Volt AC, 30
Amp, single-phase, 60 Hz, electrical lighting, appliance, tool and
motor loads.
6. 120/240 Volt AC, 50 Amp Receptacle (Located on underside
of control panel)
– Supplies electrical power for the operation of
120/240 Volt AC, 50 Amp, single-phase, 60 Hz, welder or motor
loads.
7. Air
Cleaner
– Filters intake air as it is drawn into the engine.
8. Choke
Knob
– Used when starting a cold engine.
Figure 5 - Generator Controls
9. Winter/Summer
Valve
– See “Cold Weather Operation/De-icer”
section.
10. Circuit Breakers
(AC) – Each receptacle is provided with a
push-to-reset circuit breaker to protect the generator against
electrical overload. (50 amp uses toggle reset)
11. Fuel
Tank
– Tank holds 16 U.S. gallons of fuel.
12. Grounding Lug
– Ground the generator to an approved earth
ground here. See "Grounding the Generator" for details.
13. Idle Control Switch
– The idle control runs the engine at normal
(high) speeds when there is an electrical load present and runs
the engine at idle (low) speeds when a load is not present.
14. Start/Run/Stop Switch
– Controls the operation of the
generator.
15. Oil Fill
– Use this point to add oil to engine.
16. Fuse - 10 Amp (Located at rear of control panel)
– Protects
the DC control circuit from overload. If this fuse element has
melted open the engine will not be able to crank and start.
Figure 6 - Engine Control Panel
14
8
9
7
15
12
11
6
Summary of Contents for Guardian ULTRA SOURCE 004583-0
Page 27: ...Section 7 Notes Portable Generator System 25...
Page 28: ...Section 7 Notes Portable Generator System 26...
Page 29: ...Section 8 Electrical Data Installation Diagram Drawing No 0G0907 B 27...
Page 36: ...Section 9 Exploded Views and Parts Lists GT 990 GT 760 Engine Page 1 Drawing No 0E8589 Y 34...
Page 38: ...Section 9 Exploded Views and Parts Lists GT 990 GT 760 Engine Page 2 Drawing No 0E8589 Y 36...
Page 40: ...Section 9 Exploded Views and Parts Lists Generator Drawing No 0G0742 A 38...
Page 42: ...Section 9 Exploded Views and Parts Lists Control Panel Drawing No 0G0727 B 40...