background image

6

INDUSTrIAL POWEr frOM GENErAC’S  

MODULAr POWEr SySTEMS

for applications requiring greater amounts of standby 
power, the mQt100 and mQt150 models are ideal. 
available through your local Generac industrial 
dealer, the output of these gensets can be combined 
to form a Generac modular power system (mps). 
mQt series modular power systems are building 
blocks that link together to combine the power output 
equal to one large single generator. with the ability to 
parallel up to ten 100 kw units or up to ten 150 kw 
units, these generators can satisfy higher end 
requirements ranging from 100 to 1500 kw.

redundancy

because each mQt generator within the system backs up the others, critical loads receive 
extra protection and building managers enjoy greater peace of mind.

Serviceability

mQt generators use modified high volume truck or industrial engines that can be serviced 
using readily available, cost-effective parts. since each generator backs up the others, 
servicing can be accomplished without losing backup power to critical loads.

Scalability

a Generac modular power system can be expanded as facilities grow. there is no need        
to replace the system if future power requirements exceed projections and no need to       
over-spend on a larger system that might never be fully utilized. 

Flexibility

mps modules provide unmatched flexibility because they can be placed in any configuration 
side by side, end to end, together or apart. they are light enough for most rooftop 
applications and the lower weight eliminates the need for heavy-duty cranes and material 
handlers during installation.

THE GENErAC 

INDUSTrIAL DEALEr 

NETWOrk

installation, start-up and servicing of 
modular power systems require 
specialized knowledge and expertise. 
Generac industrial dealers have 
factory-trained personnel to ensure 
that your customers get the best 
possible solution, fast delivery, 
professional installation and start-up.

 
if a customer needs a diesel-powered 
generator or a generator size that is 
beyond the scope of the Qt series 
line, a Generac industrial dealer can 
meet requirements up to 9,000 kw.

Generac industrial dealer certified 
service technicians are fully trained 
on all Qt series generators and  
can provide your customers with 
hassle-free maintenance and  
service agreements.

GEMINI

®

 TWIN PACk 

fOr HIGHEST POWEr 

DENSITy

when space is at a premium and 
reliability is critical, no other 
manufacturer comes close to 
Generac’s Gemini twin pack. 

part of the mps family, these units 
feature two 500 kw generators inside 
a single, weather resistant and sound 
attenuated enclosure. the exclusive 
powermanager™ control system 
allows for combining the output of 
large, single engine gensets with a 
significant improvement in reliability.

•  Smaller footprint than many 

comparable single engine models

•  Built-in redundancy for superior 

system reliability

•  Scalable solution – up to seven 

Gemini gensets can be paralleled 
without additional switchgear for 
up to 7,000 kw in total output

•  Fast production turn around – 

often within weeks

•  Easily serviced with common parts

Modular Power SySteMS • GeMini • Bi-Fuel

BI-fUEL ™

    Longest run Times in the Industry

Generac bi-fuel generators start on diesel fuel and add natural gas as load is applied. 
during an outage, they typically operate on a mixture of up to 70% natural gas and 
30% diesel fuel (contact factory for product specifications). if the natural gas supply is 
interrupted, the generator automatically switches to 100% diesel without any power drop 
during the transition.

Benefits of Bi-fuel

•  Dramatically increased run times
•  Minimal on-site fuel storage
•  Reduced fuel maintenance
•  Reduced environmental risk
•  Lower particulate and NOx emissions

Summary of Contents for GUARDIAN QT060

Page 1: ...portable Generators Automatic Standby Generators Transfer Switches anD Accessories p r o d u c t c a t a l o g standby generators residential Commercial light industrial ...

Page 2: ...can result in the loss of air conditioning and mold damage In any climate food left in refrigerators or freezers is likely to spoil Businesses must shut down and consequently lose revenue These are significant issues for home and business owners with expensive consequences Luckily they can be avoided With sizes ranging from 8 kW to 150 kW Generac offers the broadest generator line in the industry ...

Page 3: ...0V Kitchen 2 3 15 Amp 120V Bathroom 15 Amp 120V Furnace 15 Amp 120V Sump Pump 15 Amp 120V Bedroom 2 15 Amp 120V Bedroom 3 15 Amp 120V Bathroom 2 15 Amp 120V 1 Check your air conditioner s starting requirements Starting requirements for older and or less efficient equipment may exceed recommended generator capability Additionally for any electrical equipment or appliances always check the manufactu...

Page 4: ...20 kW model includes the base fascia for a finished look and thorough protection from debris and rodents They include all the features of the 8 17 kW models above as well as the following Quiet Test The patented Quiet Test low speed exercise mode for up to 50 quieter weekly self test Increased Circuit Coverage The 20 kW model provides up to whole house protection Aluminum All Weather Enclosures Al...

Page 5: ...nce stores and restaurants 70 kW 150 kW models A superior solution for applications that require more sophisticated monitoring and diagnostic capabilities Applications range from supermarkets and pumping stations to strip malls and hotels Liquid cooled 22 150 kW R Series Controller for 22 60 kW Liquid cooled generators Full system monitoring including LED indicators for safety shutdowns fuel press...

Page 6: ...e Generac Industrial Dealers have factory trained personnel to ensure that your customers get the best possible solution fast delivery professional installation and start up If a customer needs a diesel powered generator or a generator size that is beyond the scope of the QT Series line a Generac Industrial Dealer can meet requirements up to 9 000 kW Generac Industrial Dealer certified service tec...

Page 7: ...Watts The professional grade XP Series of portable generators has been engineered for high performance Durable construction with oversized full wrap frame tubing and impact resistant corners minimizes damage from rough handling These rugged units also include True Power Technology for utility quality electrical output for sensitive electronics Low Oil Pressure Protection to protect engine from dam...

Page 8: ... the transfer switch Pre wired external connection box with a weather proof conduit for generator connections PowerManager Load Shedding Transfer Switch The PowerManager LTS is designed to allow the most efficient use of the generator by monitoring and managing the backed up selected and non selected circuits If the generator approaches overload condition the non selected circuits are cycled off a...

Page 9: ...th generators rated up to 125 Amps 30 kW Single Phase applications only The innovative GenReady load center combines three boxes into one saving space and money on generator installations 200 Amp Main Load Center 42 Space Emergency Load Center Automatic Transfer Switch Traditional Installation GenReady Installation GenReady Installation Levels Basic Advanced Complete RECOMMENDED MODEL switch QT022...

Page 10: ... above Model Description 5464 Remote annunciator panel with 8 relays 5465 Remote annunciator panel without LEDs and keypad relays only 5466 Remote annunciator panel without relays Air Cooled Scheduled Maintenance Kit Model Description 5661 7 kW 410 cc kit 5662 8 kW 410 cc kit 5663 10 kW 530 cc kit 5664 12 13 14 15 16 kW 17 18 kW 760 990 cc kit 5665 20 kW 999 cc kit Liquid Cooled Scheduled Maintena...

Page 11: ...150 N A N A N A N A N A N A N A Weight lbs NEMA 12 NEMA 3R N A N A N A N A 650 650 650 650 650 650 650 650 680 680 680 680 680 680 Model HTSN100A HTSN100G HTSN100J HTSN100K HTSN150A HTSN150G HTSN150K HTSN200A HTSN200G HTSN200J HTSN200K HTSN300A HTSN300G HTSN300J HTSN300K Amp Rating 100 100 100 100 150 150 150 200 200 200 200 300 300 300 300 Load Transition Type Open Open Open Open Open Open Open O...

Page 12: ... N A N A Yes N A Yes Yes Yes Yes N A Yes Yes Covered Outlets No No No No No No No No No No No Yes Yes No Outlets 2x5 20R 4x5 20R 4x5 20R 1xL14 30R 4x5 20R 1xL14 30R 4x5 20R 1xL14 30R 4x5 20R 1xL14 30R 4x5 20R 1xL14 30R 4x5 20R 1xL14 30R GFCI 4x5 20R 1xL5 30R 1XL14 30R 1X14 50R 2x5 20R GFCI 2x5 20R 2xL5 30R 1xL14 30R 1x14 50R 1x10A 12Vdc 2x5 20R GFCI 2x5 20R 2xL5 30R 1xL14 30R 1x14 50R 1x10A 12Vdc ...

Page 13: ... V N V N V N V N V N V A S A S A S A S S S A S A S A S A S A N A N A N A N A N A N Y N Y N N N N N Y N Y N Y Q Q T 0 T 6 2 0 4 K N S N 1 Catalyst A F Ratio may not be available for all models Contact Your Generac representative for more information Model Number Enter on Order Form sample Step 1 Step 2 Step 3 Step 4 Step 5 Selection Criteria Transfer Switch R Controller RTS H 100 Controller HTS Loa...

Page 14: ...s Our products are fully integrated as complete power systems and each genset is factory tested prior to shipment Because of our ongoing commitment to quality and innovation Generac is the name that home and business owners have come to trust Commitment to service Generac is committed to providing our customers with unsurpassed after the sale service support Our nationwide dealer network has facto...

Page 15: ...ghway 59 Hillside Rd P O Box 8 Waukesha WI 53187 1 888 GENERAC MyGenerac com 2008 Generac Power Systems Inc All rights reserved Specifications are subject to change without notice Bulletin 0170030SBY Printed in USA 04 04 rev 11 08 ...

Reviews: