OPERATING DATA

COMMERCIAL 25 kW

RATING: All single phase units are rated at 1.0 power factor. STANDBY RATING: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to 
varying loads for the duration of a power outage.  There is no overload capability for this rating. Ratings are in accordance with ISO-3046-1. Design and specifications are subject to change 
without notice. Maximum wattage and current are subject to and limited by such factors as fuelBtu content, ambient temperature, altitude, engine power and condition, etc.

 

COMMERCIAL 25 kW

 

KW RATING 

25

ENGINE SIZE 

1.6 Liter 4 cyl. inline

GENERATOR OUTPUT VOLTAGE/KW - 60Hz 

KW LP 

KW NG 

AMP LP  AMP NG  CB Size

 120/208V, 

3-phase, 

0.8 

pf 

25 

24 

86.8 

83.3 

100

 

120/240V, 3-phase, 0.8 pf 

25 

24 

75.2 

72.2 

90

GENERATOR LOCKED ROTOR KVA
 AVAILABLE @ VOLTAGE DIP OF 35%

  208 or 240V 3-phase 

 

34 

 

   

 

 

ENGINE FUEL CONSUMPTION 

(Natural Gas) (Propane)

  

Natural  Gas

 

Propane  

   

 

 

(ft

3

/hr.) (gal/hr.) 

cu 

ft/hr

 Exercise 

cycle 

 

60 

0.65 

24 

  25% of rated load 

 

161 

1.76 

64

  50% of rated load 

 

253 

2.77 

101

  75% of rated load 

 

345 

3.79 

138

  100% of rated load 

 

437 

4.81 

175

   

ENGINE COOLING
 

Air flow 

(inlet air including alternator and combustion air)  

ft

3

/min.

 1,528

  System coolant capacity 

US gal. 

2.0

  Heat rejection to coolant 

 BTU/hr. 

110,000

  Max. operating air temp. on radiator 

°C (°F) 

60 (150)

  Max. ambient temperature 

°C (°F) 

50 (140)

COMBUSTION AIR REQUIREMENTS
 

Flow at rated power 60 Hz 

cfm 

90

   

SOUND EMISSIONS IN DBA

  db(A) @ 23 feet in exercise mode 

 

62 

  db(A) @ 23 feet at normal operating load 

 

74 

 

EXHAUST

  Exhaust flow at rated output 60 Hz cfm 

249 

  Exhaust temp. at muffler outlet 

°F 

1015 

ENGINE PARAMETERS
 

Rated synchronous RPM 

60 Hz 

3600

  HP at rated KW 

60 Hz 

45

POWER ADJUSTMENT FOR AMBIENT CONDITIONS

 Temperature 

Deration

   

3% for every 10 °C above - °C 

25 

   

1.65% for every 10 °F above - °F 

77

 Altitude 

Deration 

   

1% for every 100 m above - m 

183 

 

   

3% for every 1000 ft. above - ft. 

600

COMMERCIAL SERIES