Generac Power Systems G0071090 Instruction Sheet Download Page 3

Model No. G0071090

Home Standby Remote Start Kit

Instruction Sheet

3

Programming

Perform the following steps to enter the password and enable two-wire start:

1.

Verify both battery leads are connected, the 7.5 Amp fuse is installed and the generator switch is OFF (red light on
control panel is on).

NOTE: 

Once the password has been entered and you go to the EDIT screen, the password will be canceled when you

exit that screen. It can be re-entered again, if necessary.

2.

Press the ESCAPE key to display the menu screen.

3.

Press the following key sequence: 

UP, UP, ESCAPE, DOWN, UP, ESCAPE, UP.

 This will enter the password.

4.

Use the up/down arrow keys to navigate to the SUB MENU field and then press ENTER to display the sub menu.

5.

Use the up/down arrow keys to navigate to the DEALER field and then press ENTER to display the dealer menu.

6.

Use the up/down arrow keys to navigate to the DEALER-EDIT field and then press ENTER to display the dealer
edit menu.

7.

Use the up/down arrow keys to scroll through the parameters until 2 WIRE START SELECT is displayed. Press
ENTER to select this parameter as the one to be edited.

8.

Use the up/down arrow keys to change the display to read YES. 

9.

Press ENTER to store the data. Remote start is now enabled.

10.

Turn utility MLCB to ON or Closed.

11.

Place the generator switch in the AUTO mode (green light on the control panel is ON).

12.

After completing installation, verify that the two wire start is functioning properly.

PowerPact

 Controller

1.

Turn utility MLCB to OFF or Open.

2.

Open the controller/circuit breaker cover to access the generator’s controller panel.

3.

Place the generator in the OFF mode by pressing the OFF button.

4.

Remove and retain the 7.5 Amp ATO

®

 fuse.

5.

Remove the four fasteners from the top cover of the enclosure. Lift the top cover from the generator.

6.

Remove the two fasteners and remove the battery access panel inside the enclosure.

7.

Disconnect the black (-) negative lead from the battery.

Wiring

Two wires need to be added to the wire harness. One wire between the ground terminal block and start switch.
See the back side of the controller for Steps 1-12.

1.

See 

Figure 2

. Unplug the 20 pin wire harness connector (J5) from the controller panel by carefully releasing the

latch on the side of the connector. 

2.

Insert the crimp end of wire #0 (0J0973E) into location 3 on the wire harness connector (J5).

3.

Connect the other end, with the ring terminal, to the ground screw on the rear of the customer connection box.

4.

Insert the crimp end of wire #183 (0J0973D), into location 7 on the wire harness connector (J5).

5.

Connect the other end of wire #183 to the start switch.

6.

Plug the harness connector back into (J5) on the backside of the controller.

7.

Connect the ring terminal end of wire #178 (0J0973C) to the ground screw on the rear of the connection box.

8.

Connect the other end of wire # 178 to the start switch.

9.

Reconnect the black (-) negative lead to the battery.

10.

Install the battery access panel and tighten the two fasteners securely.

11.

Install the enclosure’s top cover. Tighten all four fasteners securely.

12.

Install the 7.5 Amp ATO

®

 fuse.

13.

Turn utility MLCB to ON or Closed.

Reviews: