Dimensions and Wire Ranges

®

Generac Power Systems, Inc. • S45 W29290 HWY. 59,  Waukesha, WI 53189 • generac.com

©2012 Generac Power Systems, Inc.  All rights reserved.  All specifications are subject to change without notice.  Bulletin 0186640SBY-F  Printed in U.S.A.  12/06/12

100 Amps  

EZ Switch™

®

Functions

Specifications

Features

•  Electrically operated, mechanically-held contacts for fast, positive connections.
•  Rated for all classes of load, 100% equipment rated, both inductive and resistive.
• 2 pole, 250 VAC contactors.
• 160 millisecond transfer time.

• Dual coil design.
• Main contacts are silver plated or silver alloy to resist welding and sticking.
• NEMA 1 (indoor rated) enclosure is standard on the 100 amp switch.
• 2 Year Limited Warranty.

All Timing and sensing functions originate in the generator controller.

 

Utility voltage drop-out ......................................................................................................................................................................................................................<60%

 

Timer to generator start ...................................................................................................................................... 10 second factory set, adjustable between 10-30 seconds

 

Engine warm up delay .................................................................................................................................................................................................................5 seconds

 

Standby voltage sensor ..................................................................................................................................................................................................60% for 5 seconds

 

Utility voltage pickup .........................................................................................................................................................................................................................>80%

 

Re-transfer time delay ...............................................................................................................................................................................................................15 seconds

 

Engine cool-down timer ............................................................................................................................................................................................................60 seconds

 Exerciser 

 .............................................................................................................................................................................................................. 12 minutes every 7 days

 

The transfer switch can be operated manually without power applied.

Model

RTS10EZA1

RTS12EZA1

RTS14EZA1

RTS16EZA1

Voltage

240, 1ø

240, 1ø

240, 1ø

240, 1ø

Circuits,  50A, 240V

1

 

40A, 240V

1

1

1

 

30A, 240V

1

1

 

20A, 240V

1

1

1

 

20A, 120V

3

3

6

5

 

15A, 120V

3

5

4

5

Phase

1

Rated AC Frequency

60 Hz

Enclosure Material

Steel

Enclosure Type

NEMA 1

Withstand Rating (Amps)

10,000

Lug Range

2/0 - #14

Load Transition Type

Open Transition

Wire Gauge (Hot, Neutral, Ground, Control)

10, 10, 10, 18

8, 8, 10, 18

6, 6, 8, 18

6, 6, 8, 18

Mechanical Dimensions (in inches/mm)

Model

RTS10EZA1

RTS12EZA1

RTS14EZA1

RTS16EZA1

Height  

(in./mm)

H1

26.5/673.1

H2

29.25/743

Width  

(in./mm)

W1

8.14/206.8

W2

12.5/317.5

Depth (in./mm)

7/177.8

Weight (lbs./kilos)

57/25.85

60.8/27.58

64/29.03

68/30.84

Terminal Wire Ranges

ATS Rated Amps

Switch Terminal

Neutral Lug/Stud

Ground Lug

100A 2-Pole UL

1 x 1/0-12

1 x 3/8-16 Stud

1 x 2/0-14

731.9

[28.8]

637.6

[25.1]

LEFT SIDE VIEW

642

[25.3]

76.2 [3.0]

PEA GRAVEL

MINIMUM

TRANSFER 

SWITCH

8KW - 17KW

(IF SUPPLIED)

TRANSFER 

SWITCH

20KW

(IF SUPPLIED)

1218

[47.9]

FRONT VIEW

1226

[48.3]

H2

H1

W1

W2

H2

H1

W1

W2

®

EZ Switch™

 